TS-7T INSTALLATION INSTRUCTIONS
POWER INPUT
GRAY LEADS: POWER INPUT 12 OR 24 VOLTS AC OR DC, NON-POLARIZED
CURRENT DRAW: 60 MA. MAX.
SWITCH ILLUMINATION
LEDS 12 VOLTS DC, FOR 24 VOLT OPERATION USE ENCLOSED RESISTOR
IN SERIES WITH ONE SIDE OF LED.
YELLOW WIRE: POSITIVE SIDE OF LED
BLACK WIRE: NEGATIVE SIDE OF LED
MOMENTARY OUTPUT
CONTACTS RATED 2A.@ 35 VDC
WHITE LEAD: COMMON CONTACT
WHITE/RED LEAD: NORMALLY-OPEN CONTACT
RED LEAD: NORMALLY-CLOSED CONTACT
TIMED OUTPUT
CONTACTS RATED 2A,@35 VDC
GREEN LEAD: COMMON CONTACT
VIOLET LEAD: NORMALLY-OPEN CONTACT
BLUE LEAD: NORMALLY-CLOSED CONTACT
TIME ADJUSTMENT
TIME RANGE: TWO TO 45 SECONDS
ROTATE POT TO MAX FOR MAXIMUM DELAY
TIMER WILL ACTIVATE WHEN “PUSH TO EXIT” SWITCH IS DEPRESSED.
SUBSEQUENT DEPRESSIONS OF THE SWITCH WILL RE-START THE TIMER.
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE P.O. BOX 280
DEER PARK, NY 11729
PH: 1 800 645-5538 1 631 586-4220 FAX ; 1 631 586-6500
WWW.ALARMCONTROLS.COM EMAIL: INFO@ALARMCONTROLS.COM