TS-7T INSTALLATION INSTRUCTIONS
POWER INPUT
GRAY LEADS: POWER INPUT 12 OR 24 VOLTS AC OR DC, NON-POLARIZED CURRENT DRAW: 60 MA. MAX.
SWITCH ILLUMINATION
LEDS 12 VOLTS DC, FOR 24 VOLT OPERATION USE ENCLOSED RESISTOR IN SERIES WITH ONE SIDE OF LED.
YELLOW WIRE: POSITIVE SIDE OF LED BLACK WIRE: NEGATIVE SIDE OF LED
MOMENTARY OUTPUT
CONTACTS RATED 2A.@ 35 VDC
WHITE LEAD: COMMON CONTACT WHITE/RED LEAD: NORMALLY-OPEN CONTACT RED LEAD: NORMALLY-CLOSED CONTACT
TIMED OUTPUT
CONTACTS RATED 2A,@35 VDC
GREEN LEAD: COMMON CONTACT VIOLET LEAD: NORMALLY-OPEN CONTACT BLUE LEAD: NORMALLY-CLOSED CONTACT
TIME ADJUSTMENT
TIME RANGE: TWO TO 45 SECONDS ROTATE POT TO MAX FOR MAXIMUM DELAY
TIMER WILL ACTIVATE WHEN “PUSH TO EXIT” SWITCH IS DEPRESSED. SUBSEQUENT DEPRESSIONS OF THE SWITCH WILL RE-START THE TIMER.