MOMENTARY OUTPUT CONTACTS
RATED 2A. @ 35 VDC
INSTALLATION INSTRUCTIONS
FOR
MODELS TS-2-2T, TS-3-2T, TS-4-2T, TS-5-2T
180 OHM
2 WATT
RESISTOR
RED
LED
REAR VIEW OF PLATE
NEGATIVE ( BLACK ) LEAD
POSITIVE ( RED ) LEAD
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE P.O. BOX 280
DEER PARK, NY 11729
PH: 1 800 645-5538 1 631 586-4220 FAX ; 1 631 586-6500
WWW.ALARMCONTROLS.COM EMAIL: INFO@ALARMCONTROLS.COM
TIME ADJUSTMENT
MAXIMUM TIME TURN POT
TOWARD PLATE
MINIMUM TIME TURN POT
AWAY FROM PLATE
TIME RANGE: 2 TO 45
SECONDS
TIMER INPUT VOLTAGE
12 TO 24 VOLTS AC OR DC
NON-POLARIZED
CURRENT DRAW: 60 MA.
MAXIMUM
GRAY LEADS
INTERNAL LAMP
LAMP ( BLACK ) LEAD
LAMP ( BLACK ) LEAD
TIMED OUTPUT CONTACTS
RATED 2A. @ 35 VDC
VIOLET LEAD N/O CONTACT
GREEN LEAD COM CONTACT
BLUE LEAD N/C CONTACT
YELLOW LEAD N/O CONTACT
WHITE LEAD COM CONTACT
RED LEAD N/C CONTACT
GRAY
BLACK
VIOLET
YELLOW
RED
WHITE
GREEN
BLUE
BLACK
BLACK
RED
GRAY
NOTE: TIMER WILL ACTIVATE WHEN PUSH TO EXIT
SWITCH IS DEPRESSED.SUBSEQUENT
DEPRESSIONS OF THE SWITCH WILL
RE-START THE TIMER.
RED LED 12/24 VOLTS DC
RED LED ONLY ON TS-3-2T, TS-5-2T
LED CURRENT RATING
9 MA. @ 12 VDC, 19 MA. @ 24 VDC
FOR 24 VOLT LAMP
OPERATION
ADD 180 OHM 2 WATT RESISTOR
IN SERIES WITH ONE GREEN LEAD.
INSULATE RESISTOR TO PREVENT
SHORTING.
CURENT DRAW OF BULB
71 MA. @ 12 OR 24 VOLTS AC/DC
INCANDECENT LAMP RATED 25,000
HOURS. REPLACEMENT BULB #658