![](/html/8f/8ffd/8ffd7aeecaa670e4d7933a1e00b3b334adbfebc75fa2e7d9e387124da5ba1794/bg1.png)
INTERNAL LAMP
LAMP ( GREEN ) LEAD
LAMP ( GREEN ) LEAD
180 OHM
2 WATT
RESISTOR
RED
LED
REAR VIEW OF PLATE
SWITCH 1 CONTACTS
RATED 2A. @ 12 - 28 VDC
N/C ( RED ) LEAD LOWER LUG
N/O ( BLUE ) LEAD UPPER LUG
COM ( WHITE ) LEAD TOP LUG
SWITCH 2 CONTACTS
RATED 2A. @ 12 - 28 VDC
( RED ) LEAD LOWER LUG N/C
( BLUE ) LEAD UPPER LUG N/O
( WHITE ) LEAD TOP LUG COM
RED LED 12/24 VOLTS DC
RED LED ONLY ON TS-3, TS-5
LED CURRENT RATING
9 MA. @ 12 VDC, 19 MA. @ 24
ALARM CONTROLS CORPORATION
19 BRANDYWINE DRIVE P.O. BOX 280
DEER PARK, NY 11729
PH: 1 800 645-5538 1 631 586-4220 FAX ; 1 631 586-6500
WWW.ALARMCONTROLS.COM EMAIL: INFO@ALARMCONTROLS.COM
BLACK
RED
FOR 24 VOLT LAMP
OPERATION
ADD 180 OHM 2 WATT RESISTOR
IN SERIES WITH ONE GREEN LEAD.
INSULATE RESISTOR TO PREVENT
SHORTING.
MOUNT WALLPLATE IN A
VERTICAL POSITION
MODELS TS-2-2, TS-3-2,
TS-4-2 & TS-5-2
SHOULD BE MOUNTED IN A
2.5 INCH ELECTRICAL BOX
CURENT DRAW OF BULB
71 MA. @ 12 OR 24 VOLTS
AC/DC
INCANDECENT LAMP RATED
25,000 HOURS.
REPLACEMENT BULB #658
NEGATIVE ( BLACK ) LEAD
POSITIVE ( RED ) LEAD
DOC. D-003 REV. A
7/08
INSTALLATION INSTRUCTIONS
MODELS TS-2-2, TS-3-2, TS-4-2, TS-5-2
U.L. FILE SA32686 CONFORMS TO U.L. STANDARD 294 FOR ACCESS CONTROL