Alarm Controls TS-2TD Installtion Instruction

INSTALLATION I
LED CURRENT DRAW
4mA @ 12Vdc
15mA @ 24Vdc
NOTE:
TIMER WILL ACTIVATE
WHEN
SWITCH IS
DEPRESSED.
SUBSEQUENT DEPRESSIONS OF THE SWITCH WI
LL
RE-START
THE TIMER.
INTERNAL LAMP
LED (BLACK) NEGATIVE LEAD
LED (BROWN) POSITIVE LEAD
TIMER INPUT VOLTAGE
12 TO 24 VOLTS AC OR DC
NON-POLARIZED
CURRENT DRAW: 60Ma
MAXIMUM
GREY LEADS
TIME ADJUSTMENT
MAXIMUM TIME TURN POT
TOWARD PLATE
MINIMUM TIME TURN POT
AWAY FROM PLATE
TIME RANGE: 2 TO 45
SECOND
TIMED OUTPUT CONTACTS #1
RATED 2A @ 35 Vdc
VIOLET LEAD N/O CONTACT GREEN LEAD COM CONTACT BLUE LEAD N/C CONTACT
TIMED OUTPUT CONTACTS #2
RATED 2A @ 35 Vdc
VIOLET LEAD N/O CONTACT GREEN LEAD COM CONTACT BLUE LEAD N/C CONTACT
LED ONLY AVAILABLE ON
THE TS-3TD
OPERATING POSITIVE NEGATIVE VOLTAGE LEAD LEAD
12 VOLTS WHITE BLACK 24 VOLTS RED BLACK
GREY
GREY
VIOLET GREEN
BLUE
VIOLET GREEN
BLUE
BLACK
BROWN
NSTRUCTION
S
DOUBLE TIMED CONTACTS
REAR VIEW OF PLATE
Alarm Control Phoenix, AZ 85044 (800) 645-5538 www.alarmcontrols.com
DOC. D-020 Rev. B