Model
6131
Single Zone Burglary
Control with Entry/Exit
Delay
Models
6131NT
Burglary Only, Entry/Exit Delay,
Remote Arming, Battery and
Transformer not included
Specifications
• Regulated voltage output,
13.8 VDC and 300 mA
• Power input 12 VAC, Class
2 plug-in transformer
(transformer supplied)
• 12 VDC, 4 Ah rechargeable
battery (battery not
supplied)
• Bell/siren output 12 VDC,
2.5A
• Dry contacts SPST
normally-open rated 5A at
28 VDC
• Pre-alarm output 12 VDC
for SC628 sonalert or
equal
• Cabinet size: 11" H x 9" W
x 3" D
• Closed circuit instant
loop: Instant and Delay
maximum loop resistance
1000 ohms
Features
• Adjustable entry/exit delay,
independently adjustable
from 2 to 60 seconds
• Adjustable bell cut-off,
auto restore time 2 to 15
minutes
• Latching panic circuit
• Built-in battery charger
• Built-in pulse stretcher
• Open circuit instant loop
• 24 hour latching panic
circuit
• Remote instant/delay
switch: single pole, single
throw (Delay active when
open)
• Full static and lightning
protection
• Remote LEDs: Armed LED:
Red, Secure LED: Green,
Control will accept up to
three LED remote stations
• Key switch momentary
type, round or flat key, key
switch not supplied
• Cabinet beige finish,
knockout for optional
camlock, knockout for
cabinet mounted key
switch, secure and armed
LEDs, five additional
knockouts
CONTROLS
© 2015 Hanchett Entry Systems, Inc., an ASSA ABLOY Group Company
alarmcontrols.com • 800.645.5538