Aladdin Light Lift ALL200RM-CM User Manual

ALL200RM
INSTALLATION INSTRUCTIONS
Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com
Patent #5105349
WARNING: Disconnect power source before servicing to avoid electrical shock
CAUTION: To Reduce the Risk of Electric Shock or Injury, Use Indoors Only.
Pour usage seulement dans un endroit
Avec acces au dessus du plafonds
Model Number: ALL200RM (200lb. rated working load, 1/8” steel galvanized lay cable,
1.5amp, 50/60Hz)
Light lift is equipped with a 65’ cable unless checked below: ______90’ ______120’
Light lift is equipped with a 1,650 watt (15 amps) lighting capacity unless checked below: ______2200 watts (20 amps)
________________________ Electric Hoist Manufacture Date © 2013 All Rights Reserved 91F5
Read the following guidelines prior to installing the ALL200RM:
I. e ALL200RM must be installed by a licensed, bonded, and insured electrician.
II. e ALL200RM must be installed in an accessible location.
III. oroughly read, understand, and follow each step and safety warning in the ALL200RM installation instructions and orange safety precautions supplement.
IV. Motor pulley, directional pulley(s), and chandelier pulley must be installed on the same plane. Do not install the ALL200RM with lateral cable direction changes.
V. During installation of the ALL200RM, take one step at a time and check o each step upon completion.
VI. Call Aladdin Light Lift (877) 287-4601 if assistance is needed for installation and/or operation of the ALL200RM. Refer to the Keyswitch Controller Guide or SmartLift Controller Guide for operation instructions.
VII. Ignoring any safety warnings and/or symbols not only voids the warranty, but may cause death, personal injury, and/or property damage.
VIII. e wattage of the chandelier can not exceed the wattage capacity of the ALL200RM.
IX. Give all Aladdin paperwork to property owner and/or anyone that will be using the ALL200RM.
ALL200RM Parts Bag List
A. 5/16” x 2” Lag Bolts (QTY 4)
B. 5/16” x 1¼” Fender Washers (QTY 4)
C. Screw Collar Ring (QTY 1)
D. read Lock (QTY 1)
E. 3/32” Allen Wrench (QTY 1)
ALL200 RM Hardware Box List
5/16” USS Flat Washers (QTY 4)
3/8” Nylon Lock Nuts (QTY 2)
3/8” x 1¼” Hex Tap Bolts (QTY 2)
7/16” x 4” Hex Tap Bolt (QTY 4)
3/8” USS Flat Washers (QTY 8)
7/16” Nylon Lock Nuts (QTY 4)
Side Brackets for Chandelier Pulley Bracket (QTY 2)
Flat Brackets (QTY 2) per directional pulley (optional)
7/16” x 3¼” Hex Head (QTY 2) per directional pulley (optional)
3/8” USS Flat Washers (QTY 4) per directional pulley (optional)
7/16” Nylon Lock Nuts (QTY 2) per directional pulley (optional)
STEP 1
Determine mounting location of ALL200RM motor assembly. e ALL200RM may be mounted on an angle, vertically, horizontally or upside down, if secured properly. See Diagram A.
Never install the ALL200RM where the ceiling height and total cable run through the pulleys exceeds ve feet less than the exact length of winch cable. For example, if the ALL200RM is equipped with a 65ft. cable do not install the ALL200RM with a ceiling height and total cable run that is greater than 60ft. is could cause the cable to become reverse wrapped on the winch. An ALL200RM installed with a reverse wrapped cable could cause the chandelier to fall, which could cause death, personal injury, and/ or property damage. Winch cable length can be found on the ALL200RM product sticker, shipping box, and the front page of these installation instructions.
Diagram A
Upside Down
Level
Left Angle
Vertical
Right Angle
STEP 2
Determine mounting location of chandelier pulley assembly. Chandelier pulley assembly must be mounted directly above where chandelier will hang. See Diagram B.
Never mount the chandelier pulley assembly o plane or unlevel in a remote installation. is could cause the chandelier to fall, which could cause death, personal injury, and/or property damage. e winch cable must hang plumb through the center of the top contact plate on the ceiling box.
Diagram B
Chandelier Pulley Assembly Height is Adjustable From 12” to 17”
If Ordered With Conduit Cut to Minimum Chandelier Pulley Assembly Height is Adjustable From 8⅛” to 9 ⅝”
13 ¾” Minimum
16” Maximum
STEP 3
Determine mounting location of directional pulleys if they are to be installed with ALL200RM. Directional pulleys can be used to change winch cable direction, up or down, between motor pulley and chandelier pulley. See Diagram C.
Never mount directional pulleys o plane in a remote installation. is could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
Diagram C
7”
Quick Link
4”
Flat Brackets
Suitable Structure
6”
Pulley
yes NO
STEP 4
Determine that cable position on motor pulley is correct for installation. ALL200RM is equipped with cable running under motor pulley. See Diagram D.
Never position cable on motor pulley improperly. is could damage the cable which could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
Diagram D
Under
STEP 5
If cable rubs on motor pulley housing or motor assembly plate, change cable conguration so that cable runs over motor pulley. See Diagram E.
Never position cable on motor pulley improperly. is could damage the cable which could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
Diagram E
Over
STEP 6
Position ALL200RM motor assembly where it will be mounted. Adjustments can be made loosening 3/8” channel strut bolts that hold ALL200RM motor assembly to channel struts. Retighten channel strut bolts after adjustments are made. Conrm strut nuts are seated properly. See Diagram F.
Never adjust the channel struts improperly. is could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
STEP 7
Securely fasten ALL200RM motor assembly to a suitable structure using 5/16” lag bolts and 5/16” fender washers included in parts bag. See Diagram F.
Never install the ALL200RM without properly fastening it to a suitable structure. is could interfere with the safety and operation of the ALL200RM and could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
5/16” Lag Bolts
5/16” FenderWashers
Diagram F
3/8” Channel Strut Adjustment Bolts
3/8” Channel Strut Adjustment Bolts
STEP 8
Turn o supply power before wiring ALL200RM motor switch. Turn o motor switch in square box. Wire motor switch with 110V wiring. e 110V motor feed must be kept separate from 110V light switch leg. Keep motor and light neutrals separate. Motor neutral is white and 14 gauge. Only wire motor switch at this time. See Diagram G.
Never wire the ALL200RM improperly. Make sure electricity is turned o when installing and/or performing maintenance on the ALL200RM. Improper wiring and/or electricity could cause death, personal injury, and/or property damage.
Diagram G
12 Gauge Light Neutral
12 Gauge Light Hot
Do Not Wire Light Switch At is Time
14 Gauge Motor Neutral
14 Gauge Motor Hot
Light Motor
110V House Hot For Motor
110V House Neutral For Motor