Aladdin Light Lift ALL1000-CM-240V User Manual

ALL1000-230V
INSTALLATION
INSTRUCTIONS
Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com
Patent #5105349
WARNING: Disconnect power source before servicing to avoid electrical shock
Light and motor circuits are rated at AC 230V
Pour usage seulement dans un endroit
Avec acces au dessus du plafonds
Model Number: ALL1000(455Kg rated working load,7/32” steel galvanized lay cable,1.67amp,50/60Hz) __ Greeneld _(if checked)
Light lift is equipped with a 35’(10.6m) cable unless checked below: ______65’(19.8m) ______90’(27.4m) ______120’(36.6m)
Light lift is equipped with a 2200 watt (20 amps) lighting capacity
________________________ Manufacture Date © 2012 All Rights Reser ved
Read the following guidelines prior to installing the ALL1000:
I. e ALL1000 must be installed by a licensed, bonded and insured electrician.
II. e ALL1000 must be installed level, in an accessible location and directly above the chandelier.
III. oroughly read, understand and follow each step and safety warning in the ALL1000 installation instructions and orange safety precautions supplement.
IV. During installation of the ALL1000, take one step at a time and check o each step upon completion.
V. e Troubleshooting Guide is located in the back of the Installation Instructions. Call Aladdin Light Lift (877) 287-4601 if assistance is needed for installation and/or operation of the ALL1000. Refer to the Keyswitch Controller Guide or Smartlift Controller Guide for operation instructions.
VI. Ignoring any safety warnings and/or symbols not only voids the warranty, but may cause death, personal injury and/or property damage.
VII. e wattage of the chandelier can not exceed the wattage capacity of the ALL1000.
VIII. e Warranty Agreement is located on the last page of Installation Instructions.
IX. Give all Aladdin paperwork to property owner and/or anyone that will be using ALL1000.
ALL1000 Parts Bag List
A. #10 x 1 ¼” Pan Phillips-Wood Screws (QTY 8)
B. 3/16” x 1” Fender Washers (QTY 8)
C. Screw Collar Ring (QTY 1)
D. read Lock (QTY 1)
E. 3/32” Allen Wrench (QTY 1)
F. 1/4 IPS(13mm) x 3/8 IPS(16mm) Fixture Coupler (QTY 1) 3/8 IPS(16mm) x 1/2 IPS(22mm) Fixture Coupler (QTY 1)
STEP 1
Determine where ALL1000 will mount on ceiling joists. ALL1000 must be installed level, in an accessible location directly above chandelier.
Never mount the ALL1000 o plane or unlevel in a standard installation. is could cause the chandelier to fall, which could cause death, personal injury, and/or property damage. e winch cable must hang plumb through the center of the top contact plate on the ceiling box.
Never install the ALL1000 where the ceiling height exceeds 1.5m less than the exact length of winch cable. For example, if the ALL1000 is equipped with a 35ft.(10.6m) cable, do not install the ALL1000 in a ceiling that is greater than 30ft(9.1m). is could cause the cable to become reverse wrapped on the winch. An ALL1000 installed with a reverse wrapped cable could cause the chandelier to fall, which could cause death, personal injury, and/or property damage. Winch cable length can be found on the ALL1000 product sticker, shipping box and the front page of these installation instructions.
STEP 2
After turning o power, remove and discard existing electrical box if present in ceiling. Only use ceiling box provided with ALL1000. See Diagram A.
Never remove an existing ceiling box while the power is connected. Electricity could cause death, personal injury, and/or property damage.
STEP 3
Cut a 4 ½” (11.4cm) hole in ceiling for ceiling box. If you removed an existing ceiling box, existing hole may need to be enlarged.
STEP 4
Attach conduit assembly to 3/4” conduit connector mounted below pulley. Once completely inserted, tighten set screw on conduit connector. See Diagram A.
Never attach or adjust the conduit assembly improperly. is could interfere with the automatic shuto system and could cause the chandelier to fall, which could cause death, personal injury, and/or property
damage.
Diagram A
3/4” Conduit Connector
Telescopic Conduit Assembly
ALL1000 Ceiling Box
STEP 5
Attach the 1/2” conduit connector on ceiling box to bottom of conduit assembly. Once completely inserted, tighten set screw on conduit connector. See Diagram B.
Never attach or adjust the conduit assembly improperly. is could interfere with the automatic shuto system and could cause the chandelier to fall, which could cause death, personal injury, and/or property damage.
Diagram B
1/2” Conduit Connector
STEP 6
Tighten temporary 2.3Kg weight to xure coupler on bottom contact plate. Make sure jam nut on weight is tight.
Never install or operate an ALL1000 before securing the temporary 2.3Kg weight to the xture coupler. is could cause the temporary weight to fall, which could cause death, personal injury, and/or property damage.
Loading...