AKG C419 Service Manual

Page 1
C 419 2579Z..
/
Last modification: items 31, 32 exchanged / Letzte Änderung: Pos 31, 32 vertauscht 03/2006
C 419-L
2+3: red/rot 1:screen (blue)
Schirm (blau)
C 419B-lock
C 419 C 419PP
tip/Spitze: red/rot sleeve / Hülse: screen (blue)/Schirm (blau)
C 419/WL900
inner contact/innerer Kontakt: red/rot outer contact /äusserer Kontakt:screen (blue)/Schirm (blau)
_________________________________________________________________
AKG Acoustics GmbH, A Harman International Company, Lemböckgasse 21-25, A-1230 Wien, Austria.
Tel.: (431)86654-0, FAX: (431)86654-1514, service@akg.com
, www.akg.com
Page/Seite 1 /4
Page 2
C 419 2579Z..
C 419B-lock 2579Z0001: A C 419 2579Z0002: B C 419/WL900 2579Z0003: C
Description
Capsule 1 2575Z0002 1 1 1 1 1 Kapsel Capsule housing, OLD 2 2579M1001 (1) (1) (1) - - Kapselgehäuse, ALT Holder, OLD 2.1 2578M0101 (1) (1) (1) - - Halter, ALT Holder 2.1 2578M0102 1 1 1 1 1 Halter Capsule housing, 16 cm 2 2579M1002 (1) (1) (1) - - Kapselgehäuse, 16 cm Capsule housing, 18 cm 2 2579M1003 1 1 1 1 1 Kapselgehäuse, 18 cm Capsule cover 3 2578Z1401 1 1 1 1 1 Kapseldeckel Windscreen, front 4 2578Z1501 1 1 1 1 1 Windschutz, vorne Windscreen, rear 5 2578Z1601 1 1 1 1 1 Windschutz, hinten Screw EJOT 15x5 6 0099N1500 2 2 2 2 2 Schraube EJOT 15x5 Tension relief NEW 7 2578Z2701 1 1 1 1 1 Zugentlastung NEU Cover, OLD 11 2578Z0501 (1) (1) (1) (1) - Deckel, ALT Cover 11 2578Z2801 1 1 1 1 1 Deckel Cable, 3 meters, molded 14 2517K0011 1 - - - - Kabel, 3 m, umspritzt Cable, per meter 14 1801Z6401 - 3 - - - Kabel, Meterware Cable, per meter 14 1802Z0701 - - 1,5 1,5 3 Kabel, Meterware B-lock conn., solderable Mini XLR Connector 15 0017E0340 - - - 1 - Mini XLR- Stecker Spring 16 9999N0535 1 1 1 1 1 Feder Washer 18 2578Z1201 2 2 2 2 2 Scheibe Nut 19 2578Z0301 1 1 1 1 1 Mutter Screw M2,5x6 26 0966D2500 - 1 - - 1 Schraube M2,5x6 PCB.-Assembly 27 2397M1011 - 1 - - - Print, komplett New version, compatible 27 2397M1022 - - - - 1
Cable module 28 0019E0124 - 1 - - - Kabelmodul Cable module 28 0019E0132 - - - - 1 Kabelmodul Outer clamp, molded 31 2578M0301 1 1 1 1 1 Außenklammer, umspritzt Inner clamp, molded 32 2578M0202 1 1 1 - - Innenklammer, umspritzt Inner clamp, molded 32 2578M0205 - - - 1 1 Innenklammer, umspritzt Cable tie 33 1000N0014 - 1 - - 1 Kabelbinder Cable, per meter 34 1801Z6101 x x x x x Kabel, Meterware Spring 35 9999N0536 1 1 1 1 1 Feder Locking washer 36 2578Z2301 1 1 1 1 1 Rastscheibe Sleeve 37 2366Z1401 - - 1 - - Hülse Connector 38 0016E0137 - - 1 - - Stecker Grommet 39 2366Z0801 - - 1 - - Tülle Windscreen Sticker "CE" Carrying bag
Please note: Tension relief 7 (2578Z2701) can only be used along with housing 2 (2579M1002) + cover 11 (2578Z2801). Cover 2578Z0501 fits to housing 2579M1001 only. *) for replacement purposes
Ite
m
Pos
.
14.1
W44
--
--
Part Nbr.
A B C D E Bezeichnung
Bestellnr.
0016E0269 1*) - - - - B-lock Stecker, lötbar
2344Z0101 1 1 1 1 1 Windschutz 9110U3198 - - - - 1 Haftetikette "CE" 1603P0001 - - - 1 - Zipp - Tasche
Connection of phantom adapter Anschluß des Phantomadapters
C 419PP
C 419-L 2579Z0005: D C 419PP 2579Z0008: E
Neue Version,
kompatibel
Achtung: Die Zugentlastung 7 (2578Z2701) passt nur zu Gehäuse 2 (2579M1002)+Deckel 11 (2578Z2801). Deckel 2578Z0501 passt nur auf Gehäuse 2578M1001. *) für Ersatzzwecke
C 419
Page/Seite 2 /4
Page 3
C 419 2579Z..
Important repair hints
Please NEVER solder directly at the capsule without using some kind of heat-sink such as metal brackets or a suitable pair of pliers. Avoid excessive solder temperatures and solder times exceeding 2 seconds! Inside the housing 2 the cable is secured with special adhesive. When dis-assembling the microphone it might be necessary to cut off the cable where it enters the holder and remove the rest of the cable or cable coating with a little screwdriver. Careful removal of the cable residue with a drill might also lead to the expected result. After reinstalling the new cable please secure it to part 2 or 7 using Loctite IS 424 adhesive or any other equivalent cement.
When connecting two-wire C 416 to PCB 2397M1022 use round pad for screen and square pad for red. The rectangular pad remains unused.
For variation 1(A), 3(C) and 5(D) inside the plug the blue cable core (if there is one) has to be connected to screen.
Mounting the outward cable Montage des Mikrofonkabels
Wichtige Reparaturhinweise
Löten Sie bitte NIEMALS direkt an der Kapsel, ohne für ausreichende Wärmeableitung gesorgt zu haben. Eine passend geformte Metallklammer oder eine geeignete Zange kann dazu dienen. Die Lötdauer sollte keinesfalls länger als 2 Sekunden sein! Innerhalb des Gehäuses 2 ist das Kabel durch einen Spezialkleber zugentlastet. Zum Kabeltausch kann es notwendig sei, das Kabel an der Eintrittstelle abzuschneiden und Reste von Kabel bzw. Kabelmantel mittels eines kleinen Schraubenziehers zu entfernen. Auch vorsichtiges Ausbohren wird zum gewünschtem Erfolg führen. Beim Montieren des Kabels, bitte unbedingt auf richtige Klebung achten. Als Sicherungskleber eignet sich die Type IS 424 von Loctite oder ein vergleichbares Produkt.
Bei Verwendung von C 416 mit Zweidrahtanschluss kommt der Schirm auf den runden Kontakt des Prints 2397M1022 und die rote Ader an den quadratischen Kontakt. Der rechteckige Kontakt bleibt frei.
Bei Variante 1(A) 3(C) und D(5) muss im Stecker die blaue Ader - falls vorhanden - mit dem Schirm verbunden werden.
old/alt
new/neu
Technical Specifications Technische Daten
Nominal values, if not otherwise stated Nennwerte, falls nicht anders angegeben Transmission range 50 ... 20.000 Hz Übertragungsbereich Sensitivity (no load) 6 mV/Pa = -44,5 dBv Leerlaufübertragungsfaktor Impedance 200 Ohm @ 30 ... 15.000 Hz Impedanz Nominal load impedance > 10 kOhm Nennabschluß Equivalent noise level 31 dBA (DIN 45412) Äquivalenzschalldruckpegel Temperature range - 20° ... + 60°C Temperaturbereich Rel. Humidity 99% @ + 20°C, 95% @ + 60°C Rel. Luftfeuchtigkeit Current consumption < 2,2 mA (2579Z0002) Stromverbrauch
Powering Speisung
(not for phantom powered versions) (nicht für phantomgespeiste Versionen)
+ UB, absolute maximum rating 12 V + UB, Maximalwert + UB, nominal value 7 ... 9 V + UB, Nennwert Ra, value limits > 4 kOhm, < 20 kOhm Ra, Grenzwerte Ra, typical 10 kOhm Ra, typisch
Page / Seite 3/4
Page 4
C 419 2579Z..
Wiring diagram of phantom adapter Phantomadapter, Schaltbild
Only complete boards available for replacement Nur der komplette Print ist als Ersatzteil erhältlich
_________________________________________________________________
AKG Acoustics GmbH, A Harman International Company, Lemböckgasse 21-25, A-1230 Wien, Austria.
Tel.: (431)86654-0, FAX: (431)86654-1514, service@akg.com