Aker Plastics 141067, 141069, 141071, 141073, 141075 Installation Manual

...
GUIDELINES FOR UNIT INSTALLATION
XXXXX 141067 141069 141071 141073 141075
NF-6036 SP-3232 SP-3442 SP-3448 SP-3260 SP-NAS
141068 141070 141072 141074 141076 141365
SP-3636 SP-3248 SP-3648 SP-3660 SPCN-3636 SPL-3950
Shower Pans & seated base
XXXXXX
NF-6036
141365
SPL-3950
141067
SP-3232
141068
SP-3636
141076
SPCN-3636
These guidelines are recommended by Maax Bath Inc. (hereafter “MAAX”) for the proper installation of their product. A careful review of these procedures (and any referenced publications) before starting is important in avoiding unnecessary problems resulting in an improper assembly or installation.
141075
SP-NAS
141069
SP-3442
141070
SP-3248
141071
SP-3448
Special Notes to Installer
Ü It is the sole responsibility of the installer
to determine, prior to the installation, the requirements necessary for compliance with all codes involving the unit or the installation!
ÜAll paperwork packaged with the unit and
any associated options or accessories should be saved and presented to the homeowner upon completion of the installation!
ÜAll published unit dimensions are for
reference only. Any critical dimensions required for installation should be taken directly from the unit being installed!
ÜAny independent changes made to the
unit (or to any options and accessories supplied with the unit) beyond those required for normal installation can void all warranties! (Refer to warranties for further information.)
141072
SP-3648
141073
SP-3260
141074
SP-3660
Inspection Guidelines
A careful check of the unit should be conducted upon receipt. Notify your supplier immediately if any questions or problems are encountered during this process.
DO NOT INSTALL ANY UNIT
WITHOUT FIRST ADDRESSING
QUESTIONS WHICH ARISE DURING
THE INSPECTION!
Basic Module Check
ü Check that the unit drain matches the
bathroom drain location.
ü Check for unit surface damage. ü Check unit color for coordination to
other bathroom fixtures.
Options/Accessories Check
An individual check list is included with the assembly and installation guidelines of factory authorized options. Refer to listed publications for further information before continuing.
10023063
GUIDELINES FOR UNIT INSTALLATION
Figure 1a - Unit Data and Dimensional Guidelines (Tolerance: +0/ -3 /8 inch)
Page 2
33-1/2"
7-1/2"
32"
1-1/2"
1-1/2"
6"
33-1/2"
7-1/2"
15-1/4"
32"
1-1/2"
1-1/2"
6"
15-1/4"
16"
141067
SP-3232
24"
Ø 3-3/8" Drain
32"
Ø 3-3/8" Drain
48"
17-1/4"
36"
37-1/2"
7-1/2"
35-1/2"
7-1/2"
1-1/2"
1-1/2"
34"
1-1/2"
1-1/2"
6"
6"
16-1/4"
141068
SP-3636
16"
24"
18"
24"
Ø 3-3/8" Drain
18"
36"
Ø 3-3/8" Drain
24"
48"
35-1/2"
7-1/2"
37-1/2"
1-1/2"
1-1/2"
7-1/2"
34"
6"
16-1/4"
36"
1-1/2"
1-1/2"
6"
17-1/4"
21"
141069
SP-3442
Ø 3-3/8" Drain
21"
42"
Ø 3-3/8" Drain
24"
48"
24"
33 1/2"
7 1/2"
13 1/2"
32"
1-1/2"
1-1/2"
15-1/4"
6"
36"
8 1/4"
141073
SP-3260
18"
6 1/4"
141070
SP-3248
30"
Foot Ledge
3"
Foot Ledge
Flange
60"
60"
Flange
16"
60"
Ø 3-3/8" Drain
30"
Seat
30"
Seat
37 1/4"
1 1/4"
22"
37-1/2"
7-1/2"
22 3/4"
36"
1-1/2"
1-1/2"
17-1/4"
6"
24"
141071
SP-3448
141074
SP-3660
XXXXX
NF-6036
141072
SP-3648
19-1/4"
Ø 3-3/8" Drain
30"
60"
30"
40-1/4"
4"
39-1/4"
1"
1"
3"
141365
SPL-3950
25-1/4"
Ø 3-3/8" Drain
25-1/4"
50-1/2"
10023063
GUIDELINES
MODEL ABCDE
141067 /
SP-3232
32" 33-1/2" 32" 15-1/4" 16"
141068 /
SP-3636
36" 37-1/2" 36" 17-1/4" 18"
141069 /
SP-3442
42" 35-1/2" 34" 16-1/4" 21"
141070 /
SP-3248
48" 33-1/2" 32" 15-1/4" 24"
141071 /
SP-3448
48" 35-1/2" 34" 16-1/4" 24"
141072 /
SP-3648
48" 37-1/2" 36" 17-1/4" 24"
141073 /
SP-3260
60" 33-1/2" 32" 15-1/4" 30"
141074 /
SP-3660
60" 37-1/2" 36" 17-1/4" 30"
MODELABCDEF
141075 /
SP-NAS
38" 38" 36-1/2" 36-1/2" 14-1/2" 14-1/2"
141076 /
SPCN-3636
38" 38" 36-1/2" 36-1/2" 14-1/2" 14-1/2"
141365 /
SPL-3950
50-1/2" 40-1/4"39-1/4" 19-1/4" 25-1/4"
MODELABCDE
XXXXX /
NS-6036
60" 37 1/4" 36" 18" 30-1/8"
FOR UNIT INSTALLATION
Figure 1b - Unit Data and Dimensional Guidelines (Tolerance: +0/ -3 /8 inch)
Page 3
7-1/2"
39-3/4"
1-1/2"
1-1/2"
6"
Fixture Blocks
38"
36-1/2"
141075
SP-NAS
14-1/2"
51-3/4"
14-1/2"
Ø 3-3/8" Drain
36-1/2"
38"
1-1/2"
7-1/2"
42"
1-1/2"
1-1/2"
6"
Fixture Blocks
38"
36-1/2"
141076
SPCN-3636
14-1/2"
51-3/4"
14-1/2"
Ø 3-3/8" Drain
36-1/2"
38"
1-1/2"
B
Unit Rough-In Depth
Minimum Alcove Depth
Drain Cut-Out
D
Drain Center
Drain
Cut-Out
5"
E
Drain Center
A
Alcove Lenght / Unit Lenght
Drain Cut-Out
Minimum Alcove Depth
Unit Rough-In Depth
Drain Center
A
E
F
C
Finished Unit Depth
Drain Center
B
Unit Rough-In Depth
Minimum Alcove Depth
5"
Finished Unit Depth
C
Drain
Cut-Out
D
Finished Unit Depth
Framing Requirements