This manual is the latest at the time of printing, and does not
include the modification which may be made after the printing,
by the constant improvement of product.
Safety Precaution
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclo
sure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER-SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL ONLY.
PRECAUTIONS DURING
SERVICING
1. In addition to safety, other parts and
assemblies are specified for conformance with
such regulations as those applying to spurious
radiation. These must also be replaced only
with specified replacements.
Examples: RF converters, tuner units, antenna
selection switches, RF cables, noise-blocking
capacitors, noise-blocking filters, etc.
2. Use specified internal Wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
3. Use specified insulating materials for hazardous
live parts. Note especially:
1) Insulating Tape
2) PVC tubing
3) Spacers (insulating barriers)
4) Insulating sheets for transistors
5) Plastic screws for fixing micro switches
4. When replacing AC primary side components
(transformers, power cords, noise blocking
capacitors, etc.), wrap ends of wires securely
about the terminals before soldering.
5. Make sure that wires do not contact heat
generating parts (heat sinks, oxide metal film
resistors, fusible resistors, etc.)
6. Check if replaced wires do not contact sharply
edged or pointed parts.
7. Make sure that foreign objects (screws, solder
droplets, etc.) do not remain inside the set.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
MAKE YOUR CONTRIBUTION
TO PROTECT THE
ENVIRONMENT
Used batteries with the ISO symbol
for recycling as well as small accumulators
(rechargeable batteries), mini-batteries (cells) and
starter batteries should not be thrown into the
garbage can.
Please leave them at an appropriate depot.
WARNING:
Before servicing this TV receiver, read the
SAFETY INSTRUCTION and PRODUCT
SAFETY NOTICE.
SAFETY INSTRUCTION
The service should not be attempted by anyone
unfamiliar with the necessary instructions on this
apparatus. The following are the necessary
instructions to be observed before servicing.
1. An isolation transformer should be connected in
the power line between the receiver and the
AC line when a service is performed on the
primary of the converter transformer of the set.
2. Comply with all caution and safety related
provided on the back of the cabinet, inside the
cabinet, on the chassis or picture tube.
3. To avoid a shock hazard, always discharge the
picture tube's anode to the chassis ground
before removing the anode cap.
4. Completely discharge the high potential voltage
of the picture tube before handling. The picture
tube is a vacuum and if broken, the glass will
explode.
5. When replacing a MAIN PCB in the cabinet,
always be certain that all protective are
installed properly such as control knobs,
adjustment covers or shields, barriers, isolation
resistor networks etc.
6. When servicing is required, observe the original
lead dressing. Extra precaution should be given
to assure correct lead dressing in the high
voltage area.
7. Keep wires away from high voltage or high
tempera ture components.
8. Before returning the set to the customer,
always perform an AC leakage current check
on the exposed metallic parts of the cabinet,
such as antennas, terminals, screwheads,metal
overlay, control shafts, etc., to be sure the set
is safe to operate without danger of electrical
shock. Plug the AC line cord directly to the
AC outlet (do not use a line isolation
transformer during this check). Use an AC
voltmeter having 5K ohms volt sensitivity or
more in the following manner.
Connect a 1.5K ohm 10 watt resistor paralleled
by a 0.15µF AC type capacitor, between a
good earth ground (water pipe, conductor etc.,)
and the exposed metallic parts, one at a time.
Measure the AC voltage across the combination
of the 1.5K ohm resistor and 0.15 uF
capacitor. Reverse the AC plug at the AC
outlet and repeat the AC voltage measurements
for each exposed metallic part.
The measured voltage must not exceed 0.3V
RMS.
This corresponds to 0.5mA AC. Any value
exceeding this limit constitutes a potential
shock hazard and must be corrected
immediately.
The resistance measurement should be done
between accessible exposed metal parts and
power cord plug prongs with the power switch
"ON". The resistance should be more than
6M ohms.
AC VOLTMETER
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in this
apparatus have special safety-related
characteristics.
These characteristics are offer passed
unnoticed by visual spection and the protection
afforded by them cannot necessarily be obtained
by using replacement components rates for a
higher voltage, wattage, etc.
The replacement parts which have these
special safety characteristics are identified by
marks on the schematic diagram and on the parts
list.
Before replacing any of these components,
read the parts list in this manual carefully. The
use of substitute replacement parts which do not
have the same safety characteristics as specified
in the parts list may create shock, fire, or other
hazards.
9. Must be sure that the ground wire of the AC
inlet is connected with the ground of the
apparatus properly.
Good earth ground
such as the water
pipe, conductor,
etc.
AC Leakage Current Check
Place this probe
on each exposed
metallic part
Technical Specifications
MODEL :
PDP-5006H
50” Plasma Display
DATE FIRST ISSUED
REVISIONS
ISSUED DATE DESCRIPTION RAISED BY :
ISSUE
1
RAISED BY
CHECKED BY
NUMBER OF PAGES
9
SPECIFICATION AGREED : SIGNATURE DATE
R & D DEPARTMENT
COMMERCIAL DEPARTMENT
PRODUCTION DEPARTMENT
Q/A DEPARTMENT
CUSTOMER
SPECIFICATION APPROVED :
.
NOTE :
Only documents stamped “Controlled Document” to be used for manufacture of production parts.
6.8 Contrast : Average 60:1 (In a bright room with 150Lux at center)
Typical 5000:1 (In a dark room 1/100 White Window
pattern at center).
6.9 Peak brightness : Typical 1000cd/㎡ (1/25 White Window)
6.10 Color Coordinate Uniformity
: Contrast; Brightness and Color control at normal
setting
Test Pattern : Full white pattern
Average of point A,B,C,D and E +/- 0.01
Technical Specifications
PDP-5006H
CONTINUATION PAGE
NUMBER
5 OF 9 PAGES
6.11 Color temperature
: Contrast at center (50); Brightness center (50);
Color temperature set at Natural
x=0.285±0.02
y=0.290±0.02
6.12 Cell Defect Specifications
Subject to Panel supplier specification as appends.
7. Front Panel Control Button
7.1 Sele Up / Down Button : Push the key to selectItem up or down.
When selecting the item on OSD menu.
Volume Up/ Down Button : Push the key to increase the volume up or down.
When selecting the adjusting item on OSD menu
increase or decrease the data-bar.
Menu Button : Enter to the OSD menu.
Source Select Button : Push the key to select the input signals source.
7.2 Stand by Button : Switch on main power, or switch off to enter power
Saving modes.
7.3 Main Power Switch : Turn on or off the unit.
8. OSD Function
8.1 Picture : State (Normal,Dark,Bright,User); Display (Bright,contrast,Color,Hue)
Temp (warm,Cool,Normal,User);
Position (H-posit,V-posit,Phase,H-size,Auto Adjust)
PIP Set (Sub Win Source,Sub Win Size,PIP Size.PIP Position)
8.5 Time : Sleep (30Min,60Min,90Min,120Min,180Min)
Wake Up (Time Edit,Volume,TV Mode,Channel)
Time Set
Technical Specifications
PDP-5006H
CONTINUATION PAGE
NUMBER
6 OF 9 PAGES
9. Agency Approvals
Safety UL60950
Emissions FCC class B
10. Reliability
11.1 MTBF
: 20,000 hours(Use moving picture signal at 25°C ambient)
11. Accessories : User manual x1, Remote control x1, Stand x1, Power cord x1,
Battery x 2, Accessories box x 1,Speaker x 2,Speaker wire x2
Technical Specifications
12. Support the Signal Mode
A .D-Sub Mode (VGA or DVI)
PDP-5006H
CONTINUATION PAGE
NUMBER
7 OF 9 PAGES
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Resolution
640 x 400
640 x 480
640 x 480
640 x 480
640 x 480
720 x 400
800 x 600
800 x 600
800 x 600
800 x 600
832 x 624
1024 x 768
1024 x 768
1024 x 768
1152 x 864
1152 x 864
1152 x 864
1280 x 960
1280 x 1024
Horizontal
Frequency
(KHz)
31.47
31.50
35.00
37.50
37.86
31.47
35.16
37.90
46.90
48.08
49.00
48.40
56.50
60.00
54.53
63.86
67.52
60.02
64.00
Vertical
Frequency
(Hz)
70.08
60.00
67.00
75.00
72.81
70.08
56.25
60.32
75.00
72.19
74.00
60.00
70.00
75.00
61.13
70.02
75.02
60.02
60.01
Dot Clock
Frequency
(MHz)
25.17
25.18
30.24
31.50
31.50
28.32
36.00
40.00
49.50
50.00
57.27
65.00
75.00
78.75
80.37
94.51
108.03
108.04
108.00
B.DTV Mode
NO.
1
2
3
4
5
6
7
8
Resolution
480 i
576 i
480p(720x480)
576p(720x576)
720p(1280x720)
720p(1280x720)
1080i(1920x1080)
1080i(1920x1080)
Horizontal
Frequency
(KHz)
15.734
15.625
31.468
31.25
45.00
37.50
28.125
33.75
Vertical
Frequency
(Hz)
59.94
50.00
59.94
50.00
60.00
50.00
50.00
60.00
Dot Clock
Frequency
(MHz)
13.50
13.50
27.00
27.00
74.25
74.25
74.25
74.25
- When the signal received by the Display exceeds the allowed range, a warning message “Out Of Range”
shall appear on the screen.
- You can confirm the input signal format from the “OSD Menu”.
CONTINUATION PAGE
Technical Specifications
PDP-5006H
NUMBER 8 OF
4.4 Remote Control
Power ( ): Press to turn on and off.
Mute (
): Press to mute the sound. Press
again or press ◄ or ► to restore the sound.
P.STILL: Press to freeze the picture. Press again to restore the picture.
P.SIZE: Press to cycles through the picture size: Normal, Fill Screen, Anamorphic,
Letter Box, TV Mode or Panorama.
P. MODE: Press to cycles through the picture
mode: NORMAL, BRIGHT, DARK, USER.
S.SELE: Press to cycles through the sound select: Main window sound or Sub window
sound.
PIP: Press to turns on PIP (picture-in picture) feature. Such as Full Screen, PIP or
Split Screen.
WAP: Press to switches the Main window
S or Sub window pictures.
C/C: Press to select the Closed Caption mode.
V-Chip: Press to select the child protect mode.
TIME: Press to display the current time.
SLEEP: Press repeatedly until it displays
the time in minutes (30 Min, 60 Min, 90 Min,
120 Min, 180 Min or Off ) that you want the
PDP to remain on before shutting off. To
cancel Sleep Time, press SLEEP repeatedly
until Sleep Off appears. And you can press
◄ or ► to select sleep time shut down.
Number buttons: Use these buttons to enter password.
(Note: The 100 button is inactive in this model.)
PIP Source: Press to select the signal for Sub Window.(Only for PIP.)
F.WHITE: Press to show a full white picture.
INFO: Press to display on-screen information.
SOUND: Press to select different sound system, such as Normal, Flat, News, Cinema,
User or BBE Digital.
PICTURE: Press to select “BRIGHT”, “COLOR”, “CONTRAST”, ”HUE” or “SHARP”, and you can use◄ or ► to adjust.
EXIT: Press to return or exit OSD menu.
9
PAGES
(Continued on next page)
12
CONTINUATION PAGE
Technical Specifications
SOUND: Press to select different sound system, such as Normal, Flat, News, Cinema, User or BBE Digital.
PICTURE: Press to select “BRIGHTNESS”, “COLOR”, “CONTRAST”, ”HUE” or “SHARPNESS”, and you can use
EXIT: Press to return or exit OSD menu.
SOURCE: Press to select the signal sources directly. Such as TV, AV1, S-VIDEO,
YCbCr, YPbPr, Analog RGB or Digital RGB.
MENU: Press to display the OSD Menu.
OK: Press to enter or confirm.
used for the selection of the program when the OSD Menu is not shown on the screen.
used for the adjustment of volume when the OSD Menu is not shown on the screen.
/ : They are used as / buttons in the OSD Menu screen and they can be
/ : They are used as
/ buttons in the OSD Menu screen and they can be
or to adjust.
PDP-5006H
NUMBER
9 OF9 PAGES
PHYSICAL CHARACTERISTICS
14. Power Cord
Length : 1.8m nominal
Type : optional
15. Cabinet
15.1 Color
: silver colour as defined by colour plaque reference number
15.2 Weight
Net weight : 51.8kg
Gross weight : 74kg
15.3 Dimensions (with stand&speak)
Width : 1227.8mm
Height : 739.8mm
Depth : 120.6mm
Block Diagram
Product Specification of PDP Module
LVDS Input
Control Signal
(Serial Interface)
APL Data
Memory
Input
Controller
Interface
Controller
Driver
Timing
Controller
Display data, Driver timing
Color Plasma Display Panel
1366 X 768 pixels
Scan Driver
Vs(180V~190V)
Va(55V~65V)
Vcc(+5V)
Common sustain driver
Address Driver
☞ Applied Voltage level is specified at the time when Full-White pattern is displayed on the panel.
Block Diagram
Speaker
SCART1
Video2
S-Video
Tuner x 2
Sub Board
TDA8946
Audio AMP
MSP34x0G
Audio Decoder
uPD64083
Separator
M52790
A/V Switch
3D Y/C
Main Board
Z86229
V-Chip / CC
VPC3230D
Vide Decoder
SDA5550
TVText Pro
PW1231
De-
Interlacer
Z86229
V-Chip / CC
VPC3230D
Video Decoder
Processor
PW181
Image
AD9883A
ADC
Sil161B
DVI Receiver
MAX232C
RS232C
W78E65B
System Control
THC63LVDM83
LVDS
Transmitter
YCrCb
YPbPr
D-SUB15
DVI
D-SUB9
IR
Keypad
LED
LDVS
Header
Circuit Diagram
- Power supply board of Audio Amplifier, MPT012A
- Main (Video) board
- Sub (Audio) board
- Keypad board
- Remote control receiver board
- Remote control board
Dbh1S4909V12.sch-2 - Thu Oct 07 00:30:42 2004
Loading...
+ 65 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.