CHILL BEV-V INSTALLATION INSTRUCTIONS (P/N 9700924)
SUGGESTED MATERIALS AND EQUIPMENT NEEDED:
• (10 ft.) 3/4” PVC Pipe
• (4) 3/4” PVC Elbow Fitting
• Multipurpose glue for ABS, PVC, and CPVC
• Tubing Cutter
• PVC Pipe Cutter
• Screwdriver or Drill with Bits
• Channel-Lock Pliers
• Adjustable Wrench
• Measuring Tape
NOTE: Do NOT use copper tubing for the CO2 water line.
General
COLD PLATE
DRINK DISPENSER
ICE
Counter
Pre-Chilled
CO
W ater
2
Cold Plate
Drain
If you experience any problems with these instructions,
contact the Technical Service Department at 630-784-1000
or toll free in the U.S. at 877-392-7854.
Warranty Information
All BEV-V units will be free from defects in materials and
workmanship for a period of three years.
General Specifications
CO2 Water Connections
Drain Water Connections 3/4” (1.91 cm) PVC fittings
Operating Pressure
Electrical Connections None
3/8” (0.95 cm) barbed fittings
with 360° swivel
Min. 30 psi (2.1 kgf/cm²)
Max. 150 psi (10.5 kgf/cm²)
Installing the BEV-V
To ensure material compatibility, a multipurpose glue for ABS,
PVC, and CPVC must be used. This will ensure a proper bond
between the 3/4” PVC and the black ABS Drain Water Inlet.
The BEV-V is furnished with an assortment of plumbing fittings
and insulating tape to aid in installation. However, due to the
variety of equipment and numerous methods of making
connections, all fittings may not be used.
Syrup Lines
CO
Water Outlet
2
(To Cold-Plate)
Drain Water Inlet
(From Cold-Plate)
Drain Water Outlet
(To Floor Drain)
Thermal
Insulation
CO
Filtered
Water
2
Syrup
Drain
Floor Drain
Max
Drain
Figure 1. Typical Installation
22 inches
(55 cm)
CO2 Water Inlet
(From Carbonator)
NOTE: Do NOT attach the soda drip tray line to the BEV-V.
The excess soda in the drip tray should drain separately to
Figure 2. Specifications Diagram
the floor drain. The BEV-V should only be attached to the
cold plate drain line that contains the melted ice water.
Before installing the BEV-V, you must determine how to route the
cold plate drain line to the unit. Some dispensers route the cold
plate drain line(s) into the syrup drip tray. You will need to separate
the cold plate drain water from the drip tray by routing a new drain
line underneath the dispenser to the BEV-V (See page 2 for sug-
1. Place the BEV-V unit under the countertop where it is
intended to be installed and secure the unit in place with
the included mounting straps.
2. Use 3/4” PVC tubing to direct the Drain Water Oulet of the
BEV-V unit to the floor drain.
gested manifold assembly to redirect cold plate drain water).
1-877-392-7836 Fax: 630-784-1000 Page 1 of 2 P/N 1011074 Rev. B 11/10
A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
CHILL BEV-V INSTALLATION INSTRUCTIONS (P/N 9700924)
3. Connect the cold plate drain line to the Drain Water Inlet
on the BEV-V unit using vinyl tubing or PVC pipe.
NOTE: If using vinyl tubing, make sure there are no pinches
or kinks in the tubing.
NOTE: The cold plate drain line should be insulated to keep
water as cold as possible before it enters the unit and to
prevent condensation.
NOTE: Because the cold plate drain line is gravity fed, you
should minimize any obstructions to the flow in the tubing.
4. Turn off the fresh water supply valve.
5. Turn off or unplug the carbonator.
6. Relieve the line pressure by depressing the soda valve.
7. Locate the filtered CO2 water line from the carbonator
and connect the line to the BEV-V CO2 Water Inlet.
8. Connect the pre-chilled BEV-V CO2 Water Outlet to the
cold plate with an insulated line.
9. Turn on the fresh water supply and the carbonator.
10. Check for any water leaks.
Manifold Assembly to Re-route Cold Plate
Melt Water From Tray
This manifold assembly only applies to cold plate drink water
dispensers that have the melt water drain lines emptying into
the soda overflow tray. For proper installation of the BEV-V, it is
necessary to re-route the cold plate drain lines underneath the
dispenser and into the BEV-V drain water inlet.
COLD PLATE
DRINK DISPENSER
ICE
Syrup Lines
Soda Overflow
Trough
CO2 Water
Lines
Metal Cold Plate
Drain Nipples
Figure 3. Remove Tubing From Dispenser
Cold-Plate Drain Water
Cold Plate
SUGGESTED MATERIALS NEEDED:
• (2) 1/2” barbed tubing elbows
• (1) 1/2” barbed tubing T connector
• 6 feet 1/2” ID vinyl tubing
• (1) 1/2” tubing clamps
• (2) 1/2” L-shaped tubing turndowns as supplied with some
dispensers
To BEV-V
Drain Water Inlet
1. Remove the front service panel to gain access to the cold
plate drain line outlets.
2. Remove all existing tubing from the exit points on the cold
plate, as shown in Figure 3.
3. Construct a manifold as shown in Figure 4 to re-route the
cold plate melt water under the dispenser, following the
syrup lines, and under the cabinet to be attached to the
BEV-V drain water inlet.
4. Use tubing clamps to secure any tubing connections.
1-877-392-7836 Fax: 630-784-1000 Page 2 of 2 P/N 1011074 Rev. B 11/10
Figure 4. Manifold Construction