CHILL BEV-D INSTALLATION INSTRUCTIONS (P/N 9700925)
SUGGESTED MATERIALS AND EQUIPMENT NEEDED:
• (10 ft.) 3/4” PVC Pipe
• (4) 3/4” PVC Elbow Fitting
• Multipurpose glue for ABS, PVC, and CPVC
• Tubing Cutter
• PVC Pipe Cutter
• Screwdriver or Drill with Bits
• Channel-Lock Pliers
• Adjustable Wrench
• Measuring Tape
NOTE: Do NOT use copper tubing for the CO2 water line.
General
If you experience any problems with these instructions, contact the Technical Service Department at 630-784-1000 or toll free in the U.S. at 877-392-7854.
Warranty Information
Cold Plate
Drain Water Inlet
CO2 Water Outlet (Insulated Line to
Cold Plate)
CO2 Water Inlet
(From Carbonator)
Drain Water Outlet
to Floor Drain
General Specifications
CO2 Water Connections
Sump Water Connections 3/4” (1.91 cm) PVC fittings
Operating Pressure Max. 150 psi (10.3 kg/cm²)
Electrical Connections None
3/8” (0.95 cm) barbed fittings with 360° swivel
Installing the BEV-D
To ensure material compatibility, a multipurpose glue for ABS, PVC, and CPVC must be used. This will ensure a proper bond between the 3/4” PVC and the black ABS Drain Water Inlet.
The BEV-D is furnished with an assortment of plumbing fittings and insulating tape to aid in installation. However, due to the variety of equipment and numerous methods of making connec­tions, all fittings may not be used.
NOTE: Do NOT attach the soda drip tray line to the BEV-D. The excess soda in the drip tray should drain separately to the floor drain. The BEV-D should only be attached to the cold-plate drain line that contains the melted ice water.
1. Place the BEV-D on its side (horizontally) beneath the ice bin and attach with the included mounting straps.
NOTE: Due to gravity flow restrictions, the BEV-D must be mounted entirely beneath the ice bin.
Figure 1. Typical Installation
Thermal
Insulation
17 inches (42.5 cm)
Drain
Water Inlet
(From Cold Plate)
Drain Water Outlet
< 12 o'clock position >
(To Floor Drain)
CO
W ater Outlet
2
(To Cold Plate)
CO
W ater Inlet
2
(from Carbonator)
5.5 inches (13.8 cm)
PLUG
Alternate Drain Water Outlet
< 6 o'clock position >
(Insert Plug)
Figure 2. Specifications Diagram
2. Position the BEV-D so the two 3/4” PVC Drain Water Outlets are oriented in the 12 o’clock and 6 o’clock positions.
3. Glue the PVC plug in the 6 o’clock PVC Drain Water Outlet.
4. Install a PVC drain line from the 12 o’clock Drain Water Outlet to the floor drain.
1-877-392-7836 Fax: 630-784-1000 Page 1 of 2 P/N 1011075 Rev. B 11/10
A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188
CHILL BEV-D INSTALLATION INSTRUCTIONS (P/N 9700925)
5. Attach the cold-plate melt line to the 3/4” Drain Water Inlet. This line can be vinyl tubing or PVC pipe.
NOTE: If using vinyl tubing, make sure there are no pinches or kinks in the tubing.
NOTE: This line should be insulated to keep the water as cold as possible before it enters the unit and prevent con­densation.
NOTE: Because the cold plate drain line is gravity fed, you should minimize any obstructions to the flow in the tubing.
6. Turn off the fresh water supply valve.
7. Turn off or unplug the carbonator.
8. Relieve the line pressure by depressing the soda valve.
9. Locate the filtered CO2 water line from the carbonator and connect the line to the BEV-D CO2 Water Inlet as indicated on the unit.
10. Connect the pre-chilled BEV-D CO2 Water Outlet to the cold plate with an insulated line.
11. Turn on the fresh water supply and the carbonator.
12. Check for water leaks.
1-877-392-7836 Fax: 630-784-1000 Page 2 of 2 P/N 1011075 Rev. B 11/10