• Provides Contaminant-Free Interior for PCR Applications
and Protects Against Cross-Contamination
• Meets or Exceeds OSHA, ANSI, and Other International Standards
“The World’s Most Extensive Selection of Benchtop PCR Cabinets.”
49 wat t1 Purair PCR 24
49–70 watts
The single EC blower motor assures
lower cost of ownership in one of the
world’s most energy efficient laminar
flow cabinets.
1
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
INTRODUCTION
The Purair® PCR laminar flow cabinet
™
employs the Air Science Multiplex
Filtration technology to create a safe,
energy-efficient, contaminant-free
environment. It is ideally suited for use
when flexible access to instrumentation
inside the cabinet is required.
49–70 watts
The single EC blower motor assures
lower cost of ownership in one of the
world’s most energy efficient laminar
flow cabinets.
HEPA
1
KEY FEATURES
• Provides sterile work zone for aseptic techniques.
• Air cleanliness meets and exceeds ISO Class 5.
• High efficiency ebm-papst EC blower.
• Energy saving LED lighting.
• Vertical laminar airflow with HEPA filtration.
• Equipped with germicidal UV lamp for decontamination.
• 360 degree visibility with UV absorbing polycarbonate construction.
Laminar Flow Cabinets
24 • 36 • 48
\\
PRODUCT OVERVIEW
\\
2
APPLICATIONS
PCR cabinets are intended for use in
non-hazardous applications where biological
or biohazard byproducts are not generated
and user protection is not required.
PCR Laboratories \ Forensics \ Pharmaceutical \
Sample Preparation \ General Research Protocols
Deep in to its second g eneration, Ai r Science em braces the di versity and
cultura l heritage of the fou nders and co- workers who are co ntinuing a
tradition of excellence. De monstrating a com mitment to adaptation,
inclu sion, and qual ity output fro m a United States- based comp any with
Polymerase chain reac tion* (PCR) is a simple and inexpensive technique
to make multiple copies of a targeted nucleotide sequence from a DNA
sample and to amplify sequences from small samples. This technique is
widely used in genetics laboratories that work with DNA and RNA.
Because PCR amplification is extremely sensitive to contamination,
prevention of contamination requires good laboratory practices to
minimize external or cross-contamination during reagent preparation,
sample preparation, and sample amplification.
* Polymerase chain reaction (PCR) is a patented process
owned by Hoffman La Roche.
70 wat t1 Purair PCR- 48 shown
with optional mobile cart.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
G
N
J
H
Laminar Flow Cabinets
24 • 36 • 48
\\
DESIGN FEATURES
\\
3
DESIGN FEATURES
A. Control Panel: The integrated control panel
features an On/Off switch for the fan, light,
C
D
B
F
K
A
I
L
M
E
and UV lamp timer.
B. Main Filter: Main HEPA filter with 99.99% efficiency
for 0.3 micron particulates.
C. Pre-Filter: The pre-filter can be changed while the
unit is operating to prevent operator exposure to
chemical vapors.
D. Fan: High-performance ebm-papst EC fan.
E. Stand: Optional base stand converts to mobile
cart with optional locking casters.
F. Lighting: Compact LED cabinet lamp located away
from laminar flow area.
G. UV Lamp: Built-in ultraviolet lamp with timer
permits decontamination between PCR cycles.
Includes a double-flap safety cover of 0.2" (5 mm)
UV absorbing 254 nm beta radiation resistant
polycarbonate; provides superior operator
protection while allowing easy access
to the work zone. Timer can be set over range
of 0 to 60 minutes or set to HOLD.
H. Pass Through Ports: Convenient rear wall pass-
through ports for safe routing of instrument
cords, cables, and leads.
I. Filter Door Lock: Prevents unauthorized removal
or accidental exposure to dirty filters.
J. Ergonomic Design: Ergonomically angled front
improves reach and user comfort.
K. Work Surface: Large polypropylene work surface,
white or black standard with optional stainless
steel work surface available.
L. Decontamination Shelf: Mounted on the back wall
near the UV lamp for maximum exposure.
M. Magnetic Door Latch: Safety interlock prevents
operator exposure to UVs when door is opened
during decontamination cycle.
N. Double-Hinged Self-Locking Front Sash: The
magnetic sash closure protects samples on the
work surface from contamination with up to 90
fpm air flow.
ADDITIONAL FEATURES
360 Degree Visibility: Clear back and side panels allow
ambient light into the chamber and provide users with
an unobstructed view of contents.
Standards Compliant: Performance specifications and
construction meet or exceed relevant standards to
ensure operator safety.
Construction: All models are available in either metal
or polypropylene construction, specify when ordering.
Available in 120V, 60Hz or 230V, 50Hz models.
120 6th Street, Fort Myers, FL 33907
Toll Free. 800-306-0656 \ www.airscience.com
49 wat t1 Purair PCR-24, shown with optional stainless steel spill tray and mobile cart.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
Each Air Science PCR work station is expertly
designed to meet specific applications
and certified for quality construction.
Standard features, options, and accessories
are developed purposefully to enhance
user-friendliness.
PERFORMANCE
The Air Science Multiplex Filter offers a range
of options for high performance protection.
Multiplex filter configuration permits a
customized combination of filter media for
a broad range of chemical families and
biological agents if required.
PCR work stations maintain up to 0.45 m/s (90 fpm)
airflow velocity, measured 6" (150 mm) from the
filter face.
The HEPA filters are easy to replace; no tools required.
243648
SELECTION
Purair PCR cabinets are available in three model sizes with various
options. Designed for desktop use or installation on an optional
base stand or mobile cart.
CONTROL
The standard integrated control panel features an On/Of f switch for
the fan, light, and UV lamp timer.
The optional Monitair® microprocessor controller with LCD display
monitors cabinet operating parameters, airflow, containment, and filter
condition and emits audio and visual alerts if conditions become unsafe.
Standard Controller
Laminar Flow Cabinets
24 • 36 • 48
\\
PERFORMANCE & SELECTION
\\
DESIGN
Professional qualit y Air Science laminar flow hoods comply with
current technical and safety regulations.
The cabinet frame and work surfaces, comprised of industrial
components, are durable and chemically resistant.
The Air Science filter assembly is easy to access, easy to change,
plus a unique filter clamping design eliminates bypass leakage of
the main filter.
An optional stainless steel work surface includes lips on
all four sides to contain spills.
Stackable sections make cabinets highly portable and
enable quick setup.
RELIABILITY
Air Science PCR work stations use an energy-efficient ebm-papst
EC blower for long life and dependable performance.
Air Science uses long-life HEPA filters without aluminum
separators to increase filter efficiency, minimize the potential for
leakage, and increase filter life.
4
Energy-efficient ebm-papst
brand EC blowers promote
long life and dependable
performance of Purair PCR
Laminar flow cabinets.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
FILTRATION
At the heart of the PCR work station is innovative
filtration technology. The Multiplex Filtration System
consists of a pre-filter and main filter. The mechanical
design enhances safety, convenience, and overall
value.
• The disposable pre-filter is accessible from
the exterior top of the cabinet.
• A filter clamping mechanism allows for the
filter to be easily installed and ensures an
even seal at the filter peripheral face at all
times to prevent bypass leakage.
• The filter chamber prevents contaminated
air from contacting internal cabinet
mechanisms.
AIRFLOW
Room air enters from the top of the cabinet through the disposable
pre-filter where larger particles are trapped, increasing the service
life of the main HEPA filter.
Air is forced evenly across the HEPA filter to deliver a flow of pure,
uniform air within the work zone to dilute and flush airborne contaminants from the work area. A nominal filter face velocity of up to 0.45
m/s (90 fpm) ensures that there is suf ficient number of air changes
within the work zone to eliminate cross-contamination and to maintain
optimum cleanliness.
Purified air travels across the work zone to the work surface in a
vertical, unidirec tional downflow stream and then exit s the work zone
across the open cabinet front.
FILTER CONFIGURATION
P. The pre-filter may be replaced while unit is in operation.
H. The main filter is easy to replace; no tools required. The filter
clamps tightly against the filter gasket to prevent filter bypass and to
maintain filter integrity.
Laminar Flow Cabinets
Pre-filter
Room Air
Intake
24 • 36 • 48
\\
CONTAINMENT & FILTRATION
\\
5
Fan / Blower
Filter disposal services are available in
selected markets providing responsible
destruction or recycling of used
saturated filters in authorized facilities.
Through our partner company Filtco Filters, Air Science is a single source supplier of all pre-filters, carbon
filters, and HEPA/ULPA filters used in our products and those of many other manufacturers.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
Disposable polyester fibers with 85% arrestance.
P
A self-contained filter designed to physically
capture particles larger than 0.3 microns (HEPA)
H
or 0.12 microns (ULPA).
Main Filter
Exhaust Air
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
Purair PCR-24Purair PCR-36Purair PCR-48Side View
MODELDIMENSIONSWEIGHT (LBS/KG)
Nominal WidthInternal Height Internal DepthExternal ( W × D × H)Shipping ( W × D × H)Net Ship
Controls<… Main On /Off switch for fan and lighting. Solid-state fan speed control with RFI filter maintains blower uniformit y. UV timer, safety interlock shut-of f. …>
Electrical<… 120V, 60Hz or 230V, 50Hz voltages available. Specify when ordering. Other voltage options available. …>
Work Surface<… Standard, black polypropylene. Optional, white polypropylene or stainless steel. Specify when ordering. …>
Pass Through Ports<… Two standard, knockout. …>
Shelving<… Decontamination shelf on rear wall. …>
Front Sash<… Standard, hinged double with safety interlock. …>
<… Vertic al downflow; 0.3 m/s - 0.45 m/s (60 - 90 fpm). …>
7
EfficiencyPCR-24PCR-36PCR-48
Power Consumption
Lighting<… LED lighting …>
UV Lamp<… 1 × 253.7 nanometer 15 watt. …>
Noise, dBA
1)
All measurements are with Filter Type ASTS-030.
2)
Measured 12" (30 cm) from the cabinet front and 15" (38 cm) above the work surface plane.
Base Cabinet, Fixed (Metal)Provides storage space below.CART-MCC-24CART-MCC-36CART-MCC-48
Base Cabinet, Fixed
(Polypropylene)
Fire Safety Cabinet BaseFlame resistant safe storage for combustible and flammable liquids.CART-FSC-24CART-FSC-36CART-FSC-48
Polypropylene Construction*Cabinets are available in all polypropylene construction.PCR-24-PPPCR-36-PPPCR-48-PP
* Factory installed; specify when ordering.
Microprocessor controller monitors cabinet operating procedures, airflow, UV, and filter condition; emits audio and visual alerts if
conditions become unsafe. Not TUV compliant.
Provides a lower storage shelf; accommodates wheelchair access. Locking casters fix the hood in place.CART-24CART-36CART-48
Provides storage space below.CART-SSC-24CART-SSC-36CART-SSC-48
MON-PMON-PMON-P
8
WARRANTY
This product is protected by the Air Science
Legacy Lifetime Warranty™ which starts on
the date of shipment from our fac tory. This
limited warranty is the result of thousands
of successful Air Science production applications in
pharmaceutical, laboratory, forensic, industrial, and
educational applications.
This warrant y covers defects in materials and
workmanship. Our liability under the Legacy Lifetime
Warranty is, at our option, to repair or replace any
defec tive parts of this equipment if you document
that these par ts were defective at the time we sold
the product to you. Normal conditions apply.
For details visit the Service section
of our website at w ww.airscience.com.
Biological Safety Filter Efficiency
HEPA a nd UL PA
Electrical SafetyUL-C-61010-1
Product DesignANSI Z 9.5-2003
OSHA, Occupational Safety
and Health Administration
EnvironmentISO 140 01
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
BS 7989-2001
AFNOR NFX 15-211
IEST- RP-CC0 034.2
IEST- RP- CC 0 0 7.1
IEST- RP-CC0 01-4
EN 182 2
CA N/C SA C22 .2 610 10 -1-12
EN 61010-1:2010
CE Mark
ROHS Exempt under EEE Category 9
ANSI Z 9.7-1998
OSHA Standard -29 CRF, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to
hazardous chemicals in laboratories. Part B, definition, laboratory type hood. All Air Science products meet this definition.
ENERGY STAR
STANDARDS & COMPLIANCE
®
Partner
CONTENTS:
Get a Quote.
Warranty Info.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Containment & Filtration (p.5)
Specifications (p.6)
Options & Accessories (p.8)
Laminar Flow Cabinets
24 • 36 • 48
\\
PCR LAMINAR FLOW CABINETS
\\
9
120 6th Street \ Fort Myers, FL 33907
T. 239-489-0024 \ Toll Free. 800-306-0656 \ F. 800-306-0677
www.airscience.com