Air Science P5-24-XT, P5-36-XT User Manual

4.3 (3)
24
36 48
XT XTS
General Application Ductless Fume Hoods
• Provides Operator Safety and Numerous Features for General Applications
Meets or Exceeds OSHA, ANSI, and Other International Standards
34 watt1 Purair model P5-36-XTS,
with optional velometer.
“The World’s Most Extensive Selection of Ductless Fume Hoods.”
22–50 watt
1
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Filtration Technology (p.5)
Specifications (p.6)
Options & Accessories (p.8)
INTRODUCTION
Purair® Basic ductless fume hoods are
designed to protect the user and the
environment from hazardous vapors
generated on the work surface.
22–50 watt
1
KEY FEATURES
• High efficiency ebm-papst EC blower.
• Energy saving LED lighting.
• Protects the operator from fume and (with added HEPA/ULPA filter) particle hazards.
• Improved filter clamping eliminates bypass leakage.
• Low airflow alarm.
Ductless Fume Hoods
24 • 36 • 48
\\
PRODUCT OVERVIEW
\\
2
APPLICATIONS
Compounding \ Balance Enclosures, Microscopes,
and Robotic Equipment \ Forensics \ Histology
\ Educational \ Microscopy \ Mobile and
Classroom Demonstrations \ Pharmaceutical \
Powder Fingerprinting \ Powder Weighing \
Sample Prep Work \ Soldering \ Solvent Cleaning
and Welding \ Veterinary \ Dental
Deep in to its second g eneration, Ai r Science em braces the di versity and cultura l heritage of the fou nders and co- workers who are co ntinuing a tradition of excellence. Demonst rating a co mmitme nt to adaptation, inclu sion, and qual ity output fro m a United States- based comp any with
120 6th Street, Fort Myers, FL 33907 Toll Free. 800-306-0656 \ www.airscience.com
a domestic and gl obal rea ch.
DUCTLESS TECHNOLOGY
The Eco-Friendly Choice
Advanced carbon filtration technology offers a safe, high performance alternative to conventional ducted fume hoods for a broad range of applications.
Environmental Benefits. Air Science® ductless fume hoods isolate and
trap chemical vapors to prevent ecological impact through release into the environment.
Versatile. Each filtration system is selec ted for its specific application.
Carbon filters are available in more than 14 configurations for use with vapors of organic solvents, acids, mercury, and formaldehyde. HEPA/ULPA filters can be added for biological safety.
Easy to Install. The ductless fume hood is self-contained and does not
require venting to the outside. Many units are portable and may be moved with minimal downtime and without filter changes. Set-up, operation, and filter maintenance are straightforward.
Energy Efficient. Because filtered air is returned to the room, no
demands are required of the facility HVAC capacity for make-up air.
Cost Effective. Facility ductwork, HVAC, and construction costs are eliminated.
Safe to Use. Cabinet air flow and face velocit y protect users from incidental
exposures to fumes.
Self-Testing. (select models) Electronic airflow monitoring assures continuous
safety. An electronic gas sensor monitors carbon filter performance.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.
50 watt1 Purair P5- 48-XT shown with
new optional FSA/Autocal controller, polypropylene spill tray and mobile cart.
CONTENTS:
Get a Quote.
Product Overview (p.2)
Design Features (p.3)
Performance & Selection (p.4)
Filtration Technology (p.5)
Specifications (p.6)
Options & Accessories (p.8)
Ductless Fume Hoods
24 • 36 • 48
\\
DESIGN FEATURES
\\
3
C
A
I
H
G
N
B
L
J
K
E
M
D
F
DESIGN FEATURES
A. Filter I.D. Window: A convenient, strategically
placed front cover window shows the installed filter par t number and installation date to encourage timely filter replacement.
B. Control Panel: Electronic controls and displays
include switches for the blower and low airflow alarm.
C. Airflow Alarm: Low airflow alarm continuously
monitors filter loading and alerts user when service is needed.
D. Air Velometer: An optional analog air velocity
meter is positioned in the user's field of vision.
E. Steel Support Frame: The chemical resistant
epoxy coated steel frame adds mechanical strength. Optional all polypropylene construction is available if desired; see accessories.
F. Hinged Front Sash: When closed, the cabinet
sash protects the contents from inadvertent external contact and bet ter isolates the air within. The sash is easy to open and close.
G. Work Surface: The internal work surface can be
fitted with an optional polypropylene (available in white and black) or stainless steel tray; see accessories.
H. Pass Through Ports: Electrical cords and cables
are safely routed into the cabinet through por ts on the back.
I. Electrostatic Pre-Filter: The electrostatic pre-filter
is accessible from inside the chamber and 91% effective down to 1-3 microns.
J. Filter Door Key: Filter access keys prevent unau-
thorized removal or accidental exposure to dirty filters.
K. Dynamic Filtration Chamber: The dynamic
filter chamber prevents any possible leakage of contaminated air by pressurizing the fan plenum (positive air) and depressuring the filter compar tment (negative air).
L. Internal Manual Speed Controller: Authorized
personnel may set the EC blower speed as desired.
M. Stan d: Optional mobile car t with locking casters.
N. Safet y Filter: The optional carbon or HEPA/ULPA
safety filter adds an additional layer of protection.
ADDITIONAL FEATURES
360 Degree Visibility: Clear back and side panels
allow ambient light into the chamber and provide users with an unobstructed view of contents.
Standards Compliant: Performance specifications
and construction meet or exceed relevant standards to ensure operator safety.
Construction: All models are available in either
metal or polypropylene construction. Specify metal or polypropylene when ordering. See selection chart for specifications and dimensions. Available in 120V, 60Hz and 230V, 50Hz models.
120 6th Street, Fort Myers, FL 33907
Toll Free. 800-306-0656 \ www.airscience.com
22 watt1 Purair P5-24-XT, shown with optional velometer, stainless steel spill tray, and mobile cart.
This product exceeds OSHA, ANSI and other International Certification Standards. Specifications are subject to change without notice.
1)
Energy consumption disclosure is based on internal testing with primary filters during normal operation.
Power consumption published is nominal and dependent on cabinet size.