“The World’s Most Extensive Selection of Ductless Fume Hoods.”
Now available with
Utility Docking Station.
EDU™ Series Ductless Fume Hoods
are Safe for Education, Vocational Training
and Industrial Workforce Development
Meets or Exceeds OSHA, ANSI and other International Standards.
— EDU-M-40
Product FeaturesDuctless Demonstration Fume Hoods
Product Overview
p:2
p:2
Ductless Demonstration Fume Hoods
Offers 360° visibility for full participation.
Protects the class from toxic fumes.
Available in four models to meet general applications.
Filters are easy to change.
Improved filter clamping prevents bypass leakage.
Low airflow alarm warns of unsafe conditions.
Compliant with ANSI, OSHA , AFNOR and BSI
safety standards.
Portable unit with transparent front, back and side
walls for maximum visibility. The EDU series offe rs
personnel and environmental protection, optimal
energy savings and zero toxic emissions to
the room.
EDU-MOBILE, EDU-M- 60 shown
APPLICATIONS
• Science Class Lectures
• Safety Practice
Demonstrations
• Laboratory Assignments
INTRODUCTION
The EDU Series Ductless
Demonstration Fume Hoods are
designed for individual and group
applications where clear front, side
and rear walls permit 360° visibility.
The high efficiency carbon filtration
and air management system protects
both the user and the classroom
environment from hazardous vapors
generated on and above the
work surface. The EDU series units
are mounted on heavy-duty transfer
carts and are sized to fit through
standard doorways for easy
transportation from lab to lab.
EDU Series
Differential Features
Differential features
within the EDU series
are summarized below
for easy selection.
Construction
• The cabinet exterior
is 100% made in the
U.S.A., fabricated with
an epoxy-coated
steel superstructure
around clear front,
side and rear panels.
• The front safety panels
lift up on hinges for
easy access to the
interior.
• Locking casters
permit complete
portability from lab
to lab.
• The overall width
and height are sized
to fit easily through
standard doorways.
• A cart handle is
located at each
end to simplify
moving (EDU-MOBILE
and EDU-CLASSIC
models only).
• Internal fluorescent
lamps operate from
the main power
switch.
Docking Station
Prevents accidental
disconnect of services
to mobile fume hoods
and prevents unauthorized access to main
service connections
which are securely
locked away when
not in use. Features
include:
• Professional
Construction
• Key Locked
• Recess or flush wall
or bench mounted
versions available
• Isolated single switch
electrical sockets
(13 amp)
• Quick release
connections for:
water, waste, and gas
• Optional RJ45 outlet
Made in
Made in
the U.S.A.
the U.S.A.
This Product Exceeds OSHA, ANSI and Other International Standards.
This Product Exceeds OSHA, ANSI and Other International Standards.
Product FeaturesDuctless Demonstration Fume Hoods
p:3
PRODUCT FEATURES:
A. Control Panel: Electronic controls and displays include
switches for the blower and low airflow alarm.
B. Power Inlet: (right side, top)
C. Air Velometer: An analog air velocity meter in the
field of vision of the user.
D. Gas Petcock: (optional)
E.Gooseneck Water Faucet: (optional)
F. Cup Sink: (optional) Integrated polypropylene cup sink.
G. Internal Diffuser
H. Integrated Centrifugal Fan Motor/Blower Assembly
I. Front Access: Multiplex
clamp system.
J. Electrostatic Pre-Filter: The 99.5% effective electrostatic
pre- filter is accessible from inside the chamber to contain the
release of any particulates that it traps.
K. Internal Manual Speed Controller: Authorized
personnel set the centrifugal fan motor speed as desired.
L. Internal Fluorescent Lamp
M. Duplex Electrical Outlet: (optional) Externally mounted.
N. Airflow Alarm: A continuous air velocity monitoring
system alerts the operator upon unacceptable values.
O. Main Controls: Petcock and water faucet controls.
P. Cart Handle: Located on the lef t and right sides of the
EDU-MOBILE and EDU-CLASSIC models.
Q. Filter I.D. Window: A strategically placed front cover
window shows the installed filter part number and installation date for convenience and to encourage timely filter
replacement.
R. Work Surface: The internal work surface is fitted with
an optional polypropylene tray.
S. Pass Through Ports: Electrical cords and cables are safely
routed into the cabinet through ports on the back and side
walls.
T. Double-Hinged Self-Locking Front Sash: When closed,
the cabinet sash protects the operator with 100 FPM airflow.
The sash is easy to open and latch.
™
filtration system, with filter
An optional docking station prevents damage from accidental
disconnect of utility se rvices to mobile fume hoods. See Ac cessories.
Air Science
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
OTHER FEATURES:
360 Degree Visibility: Clear back and side panels allow
ambient illumination into the chamber and provide users
with an unobstructed view of its contents.
Standards Compliant: Performance specifications
and construction meet or exceed OSHA, ANSI and relevant
international standards to assure operator safety.
Construction: All models are available in either metal or
polypropylene construction. See selection chart for specifications and dimensions.
Integrated Control Panel: Easy reference to critical
information with built-in audible and visual alarms for low
airflow and filter use elapsed time.
No Installation, No Ducting Required: Self-contained,
integrated systems ideal for fixed location or mobile
applications.
Safe, Energy-Efficient Operation: All conditioned air
is safely returned to the room, minimizing impact on facility
HVAC costs.
EDU-MOBILE, EDU-M- 40 shown
Product FeaturesDuctless Demonstration Fume Hoods
p:4
THE AIR SCIENCE
PERFORMANCE
ADVANTAGE
Each Air Science
fume hood includes
features expressed
through sound
design and certified
quality construction. Options and
accessories add
functional performance to meet specific
applications.
Professional Quality.
Air Science fume
hoods comply with
current technical and
safety regulations.
Multiplex Filtration.
The Air Science
Multiplex filter offers
a range of options
for high performance protection.
Industrial
Components.
The cabinet frame
and work surfaces
are durable and
chemically resistant.
Reliability.
Internal systems
are isolated from
fumes, extending
product life.
The EDU Series Basic control panel. Standard on EDU -JUNIOR, Includes On/Off switch and low airflow alarm.
The Advanced control panel includes an On/Off switch, low airflow alarm and hour meter to aid
in determining available filter life. Standard on EDU-MOBILE, EDU-CLASSIC, and EDU-ADA.
Air Scie nce fume hoods use
energy-efficient ebmpapst™
brand centrifugal blowers
for long life, and dependable performance.
An electronic Filter Saturation Alarm (FSA) is available with the optional Advanced control panel. In addition
to all the features of the Advanced control panel the FSA adds an electronic gas sensor and emits audio and
visual alerts when the main filter needs to be changed.
The optional Monitair microprocessor controller monitors and displays cabinet operating parameters, airflow, contain-
ment, and filter condition; emits audio and visual alerts if conditions b ecome u nsafe all on a LCD display.
This Product Exceeds OSHA, ANSI and Other International Standards.
Product FeaturesDuctless Demonstration Fume Hoods
p:5
EDU SERIES DIFFERENTIAL SUMMARY
FeatureEDU-MOBILEEDU-CLASSICEDU- ADAEDU-JUNIOR
General
Description
Mounted on wheeled cart with
small side storage cab inet.
Blower s, filters and controls are
mounted below the work surface
to lower the center of gravity.
Mounted on a wheeled cart
with an enclosed chemical
storage area in th e base
cabinet.
Provides wheelchair access to
the workstation front. Controls
are mounted in a han dheld
remote box p lace d insid e the
workzone.
A basic workstation, mounted
on wheeled cart.
Airflow
Air Sampling Port
Base Cabinet
Dynamic Filter Chamber
Airflow Alarm
Hour Counter
Optional Service Fixtures,
Cup Sink
Push/Pull Handle
Dwyer Continuous
Airflow Display
Safety Filter
Storage Compartment
Track and Wheel Fil ter
Insert/Remove Function
•••
••
•••
••••
•••
••••
••
••••
•• •
••
•••
Controls
An integrated control
module located above
the work surface puts all
controls at eye level.
• A main On/Off switch
controls power to the
airflow system and
lights.
• The electronic alarm
system includes a low
airflow indicator which
warns of insufficient air
velocity through the
main filter.
• Electronic process
monitoring assures
continuous safety; an
optional electronic
gas sensor monitors
main carbon filter
performance.
Air Science
• A manually
adjustable blower
speed controller
compensates for
filter loading.
• A high-performance
ebmpapst™ centrifugal fan provides
continuous air
velocity while
the cabinet is in
operation.
• A velometer located
on the cabinet
side offers a visual
confirmation of air
velocity.
Utilities
• Optional petcocks are
available for gas and
water.
• Duplex power outlets
are mounted outside
the work area on the
cabinet front.
• Optional gooseneck
faucet is positioned
over an optional
chemically-resistant
polypropylene sink
cup integrated into
the work surface.
• Pass-thru ports are
located near the
cabinet work tray on
the left and right.
• Operates on either
Single
Access
For applications where student access is required,
units can be fitted with dual access front a nd rear.
Dual
Access
120V, 60Hz or 230V,
50Hz electrical
service.
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
Warning—Exclusions:
This filter will not absorb
hydrogen, carbon monoxide,
nitrous oxide or metha ne.
THE AIR SCIENCE
MULTIPLEX FILTRATION
TECHNOLOGY SYSTEM
The Multiplex filtration
system consists of a
pre-filter, main filter and
optional safety filter to
create a combination of
chemical and physical
architecture customized
to each application.
The mechanical design
enhances safety,
convenience and
overall value.
• The electrostatic
pre-filter is accessible
from within the
cabinet.
• A filter clamping
mechanism allows for
the filter to be easily
installed and ensures
an even seal at the
filter peripheral face
at all times to
prevent bypass
leakage.
• The filter chamber
prevents contaminated
air from contacting
internal cabinet
mechanisms.
• The main filter number
and installation date
are displayed in a
front-access window.
The Air Science carbon
filtration technique is
based on enhanced,
activated carbon
particle formulations
from specially selected,
naturally occurring raw
material superior to
wood or other organic
sources. The carbon
is treated to attain the
proper porosity and
aggregate surface area
and to react with several
ranges of aerosolized
chemicals moved
through the filter by an
air handling blower.
• The multiplex option
permits one or more
filtration options to be
combined to meet
a wider range of
multiple-use applications. Multiplexing
permits configuration
for the capture of
acids, bases and
particulates such as
biological aerosols
when paired with
HEPA or ULPA filters.
• The Air Science
carbon filter is a
self-contained
assembly sized to fit
the specified product
model number.
It is configured to
optimize airflow
across 100% of the
filter surface area for
maximum efficiency,
prolonged filter life,
optimal diffusion and
saturation capacity,
and user safety.
Air Science is the
single source supplier
for all pre-filters and
carbon filters used in its
products, plus those of
many other manufacturers worldwide.
MULTIPLEX FILTRATION SYSTEM SUMMARY
EDU-MOBILEEDU-CLASSICEDU -ADAEDU-JUNIOR
Pre-Filter
ElectrostaticProtects the main filters from aerosols, mists, dust and particulates with filter efficiency superior
Main Filter
MolecularFILTC O™ Sourced. A single carbon filter containing activated carbon granules chemically formulated
Singl e: One t ype of activate d
carbon, typically EDU formula.
Blended: A single filter with
two or mo re types of carbon
blended throughout.
Layered: A single filter with
two or mo re types of carbon
in separate layers.
Stacked: Two or more single
filters e ach with a dif ferent
type o f carbon.
Main Filter
ParticulateA self-c ontain ed filte r designed to physically capture par ticles larger tha n 0.3 microns (HEPA) or 0.12
Safety Filter
Carbon or HEPA/ULPAOptional safety filter of carbon or HEPA/ULPA adds an additional layer of protection.
to 99.5% down to 0.5 microns.
StandardStandardStandardStandard
to capture one or more specific vapors or family of vapors.
SpecifySpecifySpecifySpecify
SpecifySpecifySpecify--
SpecifySpecifySpecify--
------Specify
microns (ULPA).
SpecifySpecifySpecifySpecify
SpecifySpecifySpecify--
This Product Exceeds OSHA, ANSI and Other International Standards.
Independent testing
confirms that the
Air Science EFT system
is superior in critical
areas to other “green”
fume hood systems
recently introduced
to the industry.
AFNOR NF X 15-211
requires that three
chemicals (isoproponal,
cyclohexane and
hydrochloric acid)
be tested under ver y
precise conditions to
ascertain and establish
retention capacity
at 1% of the threshold
limit value (TLV) for
each chemical.
EDU FILTER
The high-efficiency
filter used in the Air
Science EDU is certified
to absorb a range of
chemicals commonly
used in school
curriculum associated
with basic chemistry
and environmental
sciences.
The Multiplex filter
configuration permits a
customized combination
of filter media for a broad
range of chemical families and biological agents
if required. Enhanced
Filtration Technology (EFT
broadens the Air Science
application for ductless
fume hoods.
ENHANCED
FILTRATION
TECHNOLOGY
The Air Science
Enhanced Filtration
Technology (EFT™) is
a universal filtration
system developed for
use with a wide range
of core chemical
families. These include
organic acids,
alcohols, aliphatic
hydrocarbons, aromatic
hydrocarbons, esters,
aldehydes, ketones,
ethers, halogens and
others. Although the EFT
system is weighted to
accommodate these
families, it can handle
inorganic acids as well.
The Air Science EFT
system is available as
an option on Air Science
advanced ductless
fume hoods, standard
on Purair® ECO series
fume hoods, and can
be retrofitted on many
Air Science ductless
fume hoods already in
service worldwide.
Retention Capacity (grams) for
a Single Module at 1% of the TLV
(Threshold Limit Value)
SpecificationAFNOR NF X 15-211
An optional sliding sash
permits ea sier access to the
work surface in locations with
tight horizontal clearance.
See Accessories.
Optional cup sink must be
specified when ordering.
Testing LaboratoryIBRIntertek
Product ManufacturerAir ScienceBrand E
Fil te r TypeGreen
Test Results
Isopropanol (alcohol)2052673
Cyclohexane
(aliphatic hydrocarbon)
Hydrochloric Acid
(inorganic acid)*
*Based on “core” chemical families typically used in
ductless fume hood applications, the Air Science EFT
filter offers significant advantages over filters marketed
as “universal” filters. On inorganic acids the EFT filter
provides a lesser but more realistic usable capacity in
that with moderate to heavy acid applications, all ductless fume hoods made of metal are subject to corrosion
and rust. In those appl ications Air Science recommends
its polypropylene or tota l exhaust hoods with a specially
formulated heavy duty acid filter.
1531914
120 52729*
AVOID
REVOLVING FILTERS
Air Scie nce strongly discourages the unsafe practice of
revolving secondary back-up filters into the primary filter
compartment. All Air Scie nce units are designed
to avoid this false sense of security.
In a revolving filter system, users are instructed to rotate the
secondary back-up filter into the primary filter position after
non-permissible exposure levels of chemicals are detected
within the monitoring chamber.
Depending on when the unit can be properly shut down,
the secondary filter can be loaded to the point of saturation itself, thereby creating a safety hazard if the filter is
considered new.
If a new spare filter is not immediately available, a user
may inadve rtently (or knowingly) re-install a contaminated
primary filter into the secondary location permitting the
system to operate without protection.
Additionally, the secondary filter can become contaminated as it ages, sometimes for years, on top of an
operational cabinet, losing filter efficiency by the time
it is installed.
Either practice puts both personnel and the environment
at risk, even though some manufacturers provide stickers to
label the filters as “used”.
The Air Science non-revolving filter practice ensures that
only a new filter is fitted into the primary fi lter compartment,
and permits the secondary filter to remain installed for at
least twice the change -out period, resulting in a 50%
savings in filter change -out costs.
FILTER SUMMARY
FormulaDescription
GP Plus!The most widely used filter in the range, primarily
ACRIodine and methyl io dide vapors. It is frequently
used for iodination reactions with low level
radioactive iodine.
ACMMercury vapor.
AMMRemoves vapors from dilute ammonia solutions
and to remove low molecular weight amines.
SULDes igned to remove hydrogen sulphi de
and low molecular weight mercaptans.
CYNRemoval o f hydrogen cyanide. Many cyanide
compounds will evolve HCN gas if acidified,
so this filter is normally specified if working with
any cyanide compound.
FORDesig ned to oxidize for maldehyde and glutar-
aldehyde fumes. It is wi dely used in hospital
pathology laboratories.
ETHDiethyl ether is adsorbed on activated carbon,
but bec ause of its low bo iling point, local heat
adsorption can reduce the capacity of the
filter. Special impregnation allows a chemical
reaction which increases the filter capacity.
EDUDesigne d to handle chem icals norma lly used in
a university level chemistry curriculum.
MILAs th e name implies, this fi lter is d esigned for
military applications involving war gasses.
HEPA/UPLAPowders and particulates.
Universal filtration.
This Product Exceeds OSHA, ANSI and Other International Standards.
EDU-MOBILE, EDU-M-40
shown with Multiplex filtration system.
Filtration
Electrostatic
Pre-Filter
Pre-filter may
be changed while
unit is running
Main Filters
of carbon or
HEPA/U LPA
Track and
wheel system
Room Air
Intake
Exhaust Air
The EDU-MOBILE maintains
a constant face velocity of
100 FPM in compliance with
U.S.A. and International
standards for safety and
performance. Contaminated air is pulled throug h
the Multiplex filtration
system where activated
carbon adsorbs chemical
vapors, returning clean air
to the room.
Low height and low center
of gravity for stability when
moving.
A. The main filter i s easy to
replace; no tools requi red.
The filter clamps tightly
against the filter gasket to
prevent filter bypass and to
maintain filter integrity.
Fan/Blower
EDU® CLASSIC
AIRFLOW PATTERN
Main Filters
of carbon or
HEPA/U LPA
Track and
wheel system
be changed while
unit is running
Filtration
Electrostatic
Pre-Filter
Pre-filter may
Exhaust Air
Fan/Blower
Room Air
Intake
EDU-CLASSIC, P15-ENCB
shown with Multiplex
filtration system.
The EDU-CLASSIC maintains
a constant face velocity of
100 FPM in compliance with
U.S.A. and International
standards for safety and
performance. Contaminated air is pulled throug h
the Multiplex filtration
system where activated
carbon adsorbs chemical
vapors, returning clean air
to the room.
A. The main filter i s easy to
replace; no tools requi red.
The filter clamps tightly
against the filter gasket to
prevent filter bypass and to
maintain filter integrity.
Air Science
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
EDU-ADA, P10XL-CART-RC-P
shown with Multiplex
filtration system.
The EDU-ADA maintains a
constant face velocity of
100 FPM in compliance with
U.S.A. and International
standards for safety and
performance. Contaminated air is pulled throug h
the Multiplex filtration
system where activated
carbon adsorbs chemical
vapors, returning clean air
to the room.
A. The main filter i s easy to
replace; no tools requi red.
The filter clamps tightly
against the filter gasket to
prevent filter bypass and to
maintain filter integrity.
The EDU-JUNIOR maintains
a constant face velocity
of 100 FPM in compliance
with U.S.A. and International
standards for safety and
performance. Contaminated air is pulled throug h
the Multiplex filtration
system where activated
carbon adsorbs chemical
vapors, returning clean air
to the room.
A. The main filter i s easy
to replace; no tools
required. The filter clamps
tightly against the filter
gasket to prevent filter
bypass and to maintain
filter integrity.
Air Science
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
The EDU- MOBILE is mounted on
a wheeled cart with a small side
storage compartment. Blowers,
filters and controls are mounted
beneath the work surface to lowe r
the center of gravity and simplify
moving from room to room.
Model EDU-MOBILE,
EDU-M- 40 shown
EDU-M-40EDU-M-48EDU-M-60
Side View
MODELDIMENSIONSWEIGHT
Internal Height External ( W x D x H)Shipping ( W x D x H )Net Ship
EDU-MOBILE
EDU-M- 40
EDU-M- 48
EDU-M- 60
Specificatio ns are subject to change without notice.
31.5"
800 mm
31.5"
800 mm
31.5"
800 mm
39.5" x 28.5" x 77.5"
1003 x 724 x 1968 mm
49.5" x 28.5" x 77.5"
1250 x 724 x 1968 mm
59" x 28.5" x 77.5"
1500 x 724 x 1968 mm
40" x 50 " x 80"
1016 x 1270 x 20 32 mm
40" x 60 " x 80"
1016 x 1524 x 2032 mm
40" x 70" x 8 0"
1016 x 1778 x 2032 mm
EDU-MOBILE
(optional sliding sash)
(
)
lbs/Kg
270 / 123320 / 145
370 / 168420 / 191
470 / 213520 / 236
Air Science
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
The EDU- CLASSIC has horizontal inflow with
top mounted filters and exhaust. This model is
mounted on a wheeled cart with an enclosed
chemical storage area in the cabinet base.
Model EDU- CLASSIC, P15-ENCB shown
EDU-CLASSIC
MODELDIMENSIONSWEIGHT
Internal Height Extern al ( W x D x H)Shipping ( W x D x H)Net Ship
EDU-CLASSIC
P15 - EN CB
31.5"
800 mm
The EDU-ADA permits wheelchair access to the
workstation. Controls are mounted in a handheld
remote box that can be placed adjacent to or
inside the work area.
Model EDU-ADA on mounting stand. Stand can be
fitted with optional adjustable height legs (shown)
or optional mobile locking casters.
39.5" x 28.5" x 83.5"
1003 x 724 x 2121 mm
40" x 50 " x 80"
1016 x 1270 x 20 32 mm
Side View
(
)
lbs/Kg
270 / 123320 / 145
EDU-ADA
MODELDIMENSIONSWEIGHT
Internal Height External ( W x D x H)Shipping ( W x D x H )Net Sh ip
EDU -ADA
P10XL-CART-RC-P
Specificatio ns are subject to change without notice.
Air Science
31.5"
800 mm
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
34" x 28.5" x 83.5"
864 x 724 x 2121 mm
40" x 40 " x 80"
1016 x 1016 x 2032 mm
Side View
(
)
lbs/Kg
234 / 107284 / 129
Product FeaturesDuctless Demonstration Fume Hoods
p:12
The EDU- JUNIOR is a ba sic workstation
mounted on a wheeled cart.
Model EDU-JUNIOR, P5-24XT-CART shown
EDU-JUNIOR
MODELDIMENSIONSWEIGHT
Internal Height External ( W x D x H)Shipping ( W x D x H)Net Ship
Side View
(
lbs/Kg
EDU-JUNIOR
P5-24XT-CA RT
Specificatio ns are subject to change without notice.
24"
610 m m
24" x 27" x 70"
610 x 686 x 1778 mm
40" x 40 " x 80"
1016 x 1016 x 2032 mm
176 / 80225 / 102
PRODUCT SPECIFICATIONS
EDU ModelEDU-MOBILEEDU-CLASSICEDU-ADAEDU-JUNIOR
Airflow CFM220220145135
Face Velocity FPM10 010 010 010 0
Lighting
Construction
Blower
Electrical
Electrical Switches
Monitoring
<… White epoxy ste el fram e and head unit, Clear si des and back panel. …>
<… 120V, 60Hz or 230V, 50Hz voltag es available. Specify wh en orde ring. O ther vo ltage o ptions available. …>
<… Compact fluorescent lamp. …>
<… ebmpapst centrifugal fan. …>
<… Main On/Off. …>
<… Low airflow alarm, standard. …>
)
Filter Specifications
Pre-Filter
Main Filter22 lbs / 9.6 kg (EDU-M -48 a nd EDU -M - 60 require two main filters)11 lbs / 5 kg
Air Science
®
120 6th Street • Fort Myers, FL 33907 • T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677 • www.airscience.com
<… Electrostatic, 1 lb / 0.45 kg (nominal). …>
Product OptionsDuctless Demonstration Fume Hoods
p:13
OPTIONS AND ACCESSORIES
EDU ModelEDU-MOBILEEDU-CLASSICEDU -ADAEDU -JUNIOR
Filter Saturation Alarm*An electronic g as sensor emits audi o and visual alerts when
the main filter needs to be chang ed.
Monitair Controller*Microprocessor controller monitors and displays cabinet
operating parameters, airflow, containment, and filter
condition; emits audio and visual alerts if conditions
becom e unsafe, all on LCD display.
Polypropylene Construction*Cabinets are available in all polypropylene construction.
Contact Air Science for information.
Duplex Electrical Outlet*Two NEMA 14-20 R receptacles with gro und fault interrupter.
110V service standard; international fixtures available.
Service FittingCabinets can b e fitte d with service fixtures such as
petcocks, faucets or valves.
Cup Sink, Mount s into Tray*Cup sink is fit ted into t he base tray. SINK-PS INK- PSINK-PSINK-P
Docking StationSecurity cable is shorter than utility and power
line. Prevents damage from accidental disconnect of utility
services to mobile fume hoods. Prevents unauthorized
access to main service connections which are securely
locked when not in use. Configured with isolated singl e
switch electrical so ckets, USA or Euro, 15 amp. Can be
recess ed or flush mounted. Includes key l ock, quick release
conne ctions for water, waste and ga s. An opti onal RJ45
outlet is available. Specify outlet choice when ordering.
Sliding SashVert ical sliding sash permits easier acce ss to the wo rk
surface when the mob ile fume hood is used in limited spac e
areas. Specify when ordering.
Dual AccessUnits can be fit ted with dual access f ront and rear pan els for
applications where student access is required.
* Factory installed; specify when ordering.
FSAFSAFSAFSA
MON-PMON-PMON- PN/A
EDU-M -40 -PP
EDU-M-48-PP
EDU-M -60 -PP
AS-GFIAS- GFIAS- GFIAS-GFI
<… SF-X. Specify servi ce fitting t ype (fau cet, valve, petcock)
IEST-RP- CC- 0034.2
I E S T - RP -C C0 07.1
IEST-RP-CC001-4
EN 18 22
CE Mark
RoHS Exempt under EEE Category 9
ANSI Z 9.7-1998
OSHA Standard - 29 CFR, Safety and Health Regulations for General
Industry, 1910.1450: Occupational exposure to hazardous chemicals
in laboratories. Par t B, definition, labo rator y typ e hood. All Air Scienc e
products meet this definition.
120 6th Street • Fort Myers, FL 33907
T/239.489.0024 • Toll Free/800.306.0656 • F/800.306.0677
www.airscience.com