No part of this publication may be reproduced in any form or by any means, whether
electronic, mechanical, photocopying, or recording without the written consent of OvisLink
Corp.
OvisLink Corp. has made the best effort to ensure the accuracy of the information in this
user’s guide. However, we are not liable for the inaccuracies or errors in this guide. Please
use with caution. All information is subject to change without notice
All Trademarks are properties of their respective holders.
i
AirLive POE-GSH2004L-370 User’s Manual
Copyright and Disclaimer
FCC Statement
Federal Communication Commission Interference Statement This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation. For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channels is not possible.
This device and its antenna(s) must not be co-located or operation in conjunction with any
other antenna or transmitter.
IMPORTANT NOTE
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
The POE-GSH2004L-370 is a Power Control POE Web Smart Switch, and total power is
370W. This Switch is a standard switch that meets all IEEE 802.3/u/x/z Gigabit, Fast
Ethernet specifications. The switch has 20 10/100/1000Mbps TP ports and 4 Gigabit
TP/SFP transceiver slots; it supports http and SNMP interface for switch management. The
network administrator can logon the switch to monitor, configure and control each port’s
activity. In addition, the switch implements the QoS (Quality of Service), VLAN, and
Trunking. It is suitable for office application.
Others the switch increase support the Power saving for reduce the power consumption
with "ActiPHY Power Management" and "PerfectReach Power Management" two technique.
It could efficient saving the switch power with auto detect the client idle and cable length to
provide different power.
These 24 10/100/1000Mbps RJ-45 support the IEEE 802.3at PoE protocol. Each port and
transmit a maximum power 30 watts. User can also enable or disable power supply on PoE
ports from UI.
In this switch, Port 21, 22, 23, 24 includes two types of media --- TP and SFP Fiber (LC);
these ports supports 10/100/1000Mbps TP or 100/1000Mbps SFP Fiber with auto-detected
function. 1000Mbps SFP Fiber transceiver is used for high speed connection expansion.
This user’s manual will help you to uncover most functions of the POE-GSH2004L-370 with
step-by-step instructions presented by high quality illustrations. Thank you for choosing
OvisLink’s product.
Notice
This switch is using 48V 802.3at PoE standard. It does not work with passive PoE. Do not
connect with passive PoE devices
When plug in the SFP module, the device will activate mini-GBIC, and the RJ45 port will
be disabled.
1.2 Guide to the Chapters
Chapter 1:Introduction and Quick Setup guide. All the essential information including
IP Address and Password information are in the Quick Setup section.
Chapter 2: Detail installation instruction.
Chapter 3: LED indicators
Chapter 4: Detail information on Web management including how to setup remote
management.
AirLive POE-GSH2004L-370 User’s Manual
2
1. Introduction
LED
Color/Status
Description
System
Green
Power on
10/100/1000Ethernet TP Port 1 to 24 LED
Green On
Link Up
Green Blinking
Data activating
Green On
Link 1000Mbps
Yellow On
Link 10/100Mbps
1000SX/LX Gigabit Fiber Port 21,22,23,24 LED
Green On
Link Up
Green Blinking
Data activating
Green On
Link 1000Mbps
Yellow On
Link 100Mbps
PoE
PoE
Green
PoE connecting
Important Information
1.3 Quick Setup
This section provides the essential information for experienced users to operate the switch
immediately. For detailed installation instruction, please see chapter 2 for more information.
Power-On the switch
The POE-GSH2004L-370 has a built-in power supply to operate with 100 ~ 240V AC,
50 ~ 60Hz power source.
The AC power cord connector is located at the rear of the unit and the On/Off switch is
next to the connector.
After the Switch is powered on, it will perform “self-diagnostic” test. This process takes
about 5 seconds to complete.
LED Table
Link/ ACT
SPD
The default IP address: 192.168.2.1
The default password is airlive
Link/ ACT
SPD
3
AirLive POE-GSH2004L-370 User’s Manual
1. Introduction
1.4 Installation Steps
This section lists the installation procedures in steps. Each step’s instruction is thoroughly
explained in the subsequent sections of following chapter.
Step1. Connect your device's PoE port to the switch's POE port (see Figure A).
AirLive POE-GSH2004L-370 User’s Manual
4
1. Introduction
Step2. If you are using a 802.3at compliant splitter with the switch, please install it
according to Figure B.
Step3. Your PoE device should get the power from the switch now. If you want to
change settings via web management. Please follow the instructions below.
Step4. If you want to install the switch on the 19" rack, please install the mounting kit
according to Figure C.
Step5. Set your PC's IP address to 192.168.2.50.
5
AirLive POE-GSH2004L-370 User’s Manual
1. Introduction
Step6. Open your web browser and enter "192.168.2.1" to get into the switch's web
management.
Step7. Enter "airlive" for password.
Step8. If you want to install the switch on the 19" rack, please install the mounting kit.
Step9. Please see the following chapters for further configurations.
AirLive POE-GSH2004L-370 User’s Manual
6
2. Installation of the Switch
2
Installation of the
2.
Switch
This chapter provides the detailed instructions for installation of the switch. For concise
installation instruction, the previous chapter’s “Quick Setup” section provides all the
important information including IP address, password, and LED table for user’s reference.
2.1 Unpack the Package
Before you begin the installation of POE-GSH2004L-370 Web smart Switch, make sure
that you have all the necessary accessories that come with your package. Follow the steps
below to unpack your package contents:
1. Clear out an adequate space to unpack the package carton.
2. Open the package carton and take out the contents carefully.
3. Put back all the shipping materials such as plastic bag, padding and linings into the
package carton and save them for future transport need.
After unpacking and taking out the entire package contents, you should check whether you
have got the following items:
POE-GSH2004L-370
One AC Power Cord
Quick Install Guide
Support CD-ROM (The PDF version of this User’s Manual can be found within CD)
One Pair Rack-mount Kit + 8 Screws
If any of these above items is missing or damaged, please contact your local dealer for
replacement.
AirLive POE-GSH2004L-370 User’s Manual
7
2. Installation of the Switch
2.2 Hardware Overview
2.2.1 Front Panel
The front panel of the web smart switch consists of 24 10/100/1000M Base-TX RJ-45 ports
and 4 100/1000M Combo SFP ports. The LED Indicators are also located on the front
panel.
LED Indicators:
Comprehensive LED indicators display the status of the switch and the network (see the
LED Indicators chapter below).
1000BASE-T Gigabit Ethernet Ports (Port 1~24)
The Switch four Gigabit twisted pair ports, supported auto negotiable 10/100/1000Mbps
and auto MDI/MDIX crossover detection function, this function gives true “plug and play”
capability, just need to plug-in the network cable to the hub directly and don’t care if the end
node is NIC (Network Interface Card) or switch and hub. These ports can operate in
half-duplex mode for 10/100Mbps and full- duplex mode for 10/100/1000Mbps.
24 10/100/1000Mbps RJ-45 ports are PoE enable ports. These PoE ports will be
automatically activated when a compatible terminal is identified, and the PoE port will
supply power to the connected PoE device.
AirLive POE-GSH2004L-370 User’s Manual
8
2. Installation of the Switch
For legacy devices that are not yet compatible, the PoE port will not offer the power to
these devices. This feature allows users to freely and safely mix legacy and Power over
Ethernet compatible devices on their network.
Combo SFP Ports (Port 21~24)
The Switch is equipped with four combo SFP ports, supported optional 1000BASE-SX/LX
SFP module. The 1000BASE-T port 21~24 are the same ports with the SFP port 21~24,
when plug in the SFP module, the device will activate SFP, and the RJ45 port will be
disabled.
※Note: When the port was set to “Forced Mode”, the Auto MDI/MDIX will be disabled.
Mode button:
The Mode button is to change the LED’s status to Link/Act or Speed, and reset all the
setting back to the factory default by pressing the mode button for 10 seconds.
※ Note: Be sure that you recorded the setting of your device; else all the setting will be
erased when pressing the “Mode” (reset) button 10 seconds.
2.2.2 Rear Panel
The 3-pronged power plug and on/off switch are placed at the rear panel of the switch right
side shown as below.
9
AirLive POE-GSH2004L-370 User’s Manual
2. Installation of the Switch
2.3 Installation Site Preparation
You can mount POE-GSH2004L-370 either on desktop or on a 19-inch rack. If you plan to
mount the switch on desktop, please choose a steady, level surface in a well-ventilated
area that is free from excessive dust. In any case, the installation site chosen for your
switch has to comply with the following requirements:
The surface where you want to mount the switch must be able to sustain at least 2.4kg.
Do not place heavy objects (more than 3kg) on top of the switch.
The location must preferably be free from excessive dust, away from heat vent, hot-air
exhaust and direct sunlight.
The switch should not be placed near large electric motors or other strong
electromagnetic sources. As a reference, the strength of the electromagnetic field on
site should not exceed the (RFC) standards for IEC 801-3, Level 2(3V/M) field strength.
The air temperature in the location should be within a range of 32 to 122 °F (0 to 50°C).
The relative humidity in the location should not exceed 90% non-condensing humidity.
The distance between the RJ-45 port and the standard network interface should not
exceed 100 meters.
Adequate space should be allowed in front of all the ports, so that each port is easily
accessible for cable connections.
Leave at least 10cm(4 inch) of space around the switch to allow heating dissipation
2.4 Rack Mounting
The POE-GSH2004L-370 can be mounted on a standard size 19-inch rack, which can in
turn be placed in a wiring closet with other equipment.
Before you can mount the switch on the rack, first you must attach the mounting brackets
on both sides of the switch with screws, and then mount it as a unit on the rack.
To mount the unit on a rack, please follow the steps below:
Step 1. First, align the holes on the bracket with the holes on both side of the switch.
Step 2. Insert screws into the holes and then fasten the bracket on one side of the switch
with a screwdriver.
AirLive POE-GSH2004L-370 User’s Manual
10
2. Installation of the Switch
Step 3. Repeat Step 1 and 2 to fasten the bracket on the other side of the switch.
Step 4. Mount the unit on the rack and align the notches on both brackets with mounting
holes on the rack, and then secure the unit with suitable screws.
Fastening the brackets on the switch
Attaching the Switch to a 19-inch rack
11
AirLive POE-GSH2004L-370 User’s Manual
2. Installation of the Switch
2.5 Desktop Installation
The POE-GSH2004L-370 has four rubber pads attached on each corner of its underside.
These pads serve as cushioning against vibration and prevent the switch from sliding off its
position. They also allow adequate ventilation space when you place the switch on top of
another device.
Desktop installation
The location you choose to install your switch and the way you configure your network
may greatly affect its performance. Please see the previous section for “installation site”
preparation.
Do not place more than 1.5kg (6.6lbs) of weight on the top of the switch.
Leave at least 10cm of space around the switch to allow proper heating dissipation.
2.6 Cabling Requirements
For 100BASE-TX and 1000Base-T ports
The 24 RJ-45 station ports and the 1000Base-T ports of the optional Gigabit-Copper
module require Cat. 5 twisted-pair UTP/STP cable for connection. When configuring within
the 10/100/1000BASE-T cabling architecture, the cable distance should be within 100m.
The following table summarizes the cable requirement for 10/100/1000BASE-TX
connection:
AirLive POE-GSH2004L-370 User’s Manual
12
2. Installation of the Switch
Interface
RJ-45
Cable to Use
To an end station
Straight-through twisted-pair cable
To a hub/switch
Straight-through twisted-pair cable
Maximum Distance
100 meters
Connection
Specification
10BASE-T
100BASE-TX
100 ohm Category 3, 4, 5 UTP/STP cable
100 ohm Category 5 UTP/STP cable
100 ohm Category 5 UTP/STP cable or better (CAT 5E
1000BASE-T
recommended)
Auto MDI/MDI-X function
The POE-GSH2004L-370 is equipped with Auto-MDI/MDI-X function, which allows you to
use straight-through cable even when connecting to another switch/hub. Simply use the
straight-through cable for all types of 10/100BASE-TX connections, either to a PC or to a
networking device such as other hub or switch.
10 /100Base-TX and 1000Base-TPorts
Table 2-2 Cabling type for 10/100BASE-TX and 1000Base-T
2.7 Connecting to Power
POE-GSH2004L-370 features a universal auto-select power supply unit, which allows a
power connection to a wide range of input voltages from 100 to 240VAC @ 50 ~ 60Hz.
To establish its power connection, simply plug the female end of the power cord into the
power connector on the rear of the switch and the male end of the power cord into a
suitable power outlet. Once you have correctly plugged in the power, you can then turn on
the Power Switch to activate the switch.
13
AirLive POE-GSH2004L-370 User’s Manual
2. Installation of the Switch
2.8 Reset to Default
When you forgot your IP or password, please use the mode (reset) button for the factory
default setting. Please take the following steps to reset the Web Smart Switch back to the
original default:
Step 1. Turn on the POE-GSH2004L-370.
Step 2. Press and hold the mode (reset) button continuously for 10 seconds and
release the mode (reset) button.
Step 3. The switch will reboot for 30 seconds and the configuration of switch will
back to the default setting.
Key in the user ID and the password to pass the authentication; the default ID and
Password is as below,
IP Address: 192.168.2.1
Password: airlive
AirLive POE-GSH2004L-370 User’s Manual
14
3. LED Indicators
LED
Color/Status
Description
Power
Green
Power on
10/100/1000Ethernet TP Port 1 to 24 LED
Green On
Link Up
Green Blinking
Data activating
Green On
Link 1000Mbps
Yellow On
Link 10/100Mbps
1000SX/LX Gigabit Fiber Port 21,22,23,24 LED
Green On
Link Up
Green Blinking
Data activating
Green On
Link 1000Mbps
Yellow On
Link 100Mbps
PoE
PoE
Green
PoE connecting
3
LED Indicators
3.
Before connecting any network device to POE-GSH2004L-370, you should take a few
minutes to look over this chapter and get familiar with the front panel LED indicators of your
Switch.
3.1 Comprehensive LEDs
3.2 LED Table
Link/ ACT
SPD
Link/ ACT
SPD
15
AirLive POE-GSH2004L-370 User’s Manual
4. Web Management
4
Web Management
4.
The POE-GSH2004L-370 can be configured by web based interface, including System
backup/recovery, log out, and so on. The device based smart switch supports main stream
browsers, such as IE, Firefox and Chrome…etc to configure the device function. All
functions are illustrated below.
4.1 Setup your computer for Web management
The Concept of Subnet
Under the TCP/IP environment, network devices must be on the same subnet in order to
see each other. This means before you can configure the switch through web browser, you
must set your computer to the same subnet as the switch. For two network devices to be on
the same subnet, they must have the following 2 criteria
Their IP address must be on the same subnet. For example, if one IP address is
192.168.2.1. The other’s IP address must be 192.168.2.x (x is any number between 2
and 254) for Class C subnet. To find out the IP address information for your computer.
Under WinXP/Vista/Win7/Win8, please open Command Line window and type
:
“ipconfig”.
They must have the same subnet mask. For example, if one machine is 255.255.255.0.
The other machine must also set to the same 255.255.255.0 mask.
AirLive POE-GSH2004L-370 User’s Manual
16
4. Web Management
SSTTEEPP 22
SSTTEEPP 33
SSTTEEPP 11
SSTTEEPP 44
Configure your computer’s IP
Before accessing the switch through web browser, please follow the instruction below to
configure your computer’s IP to the same subnet as the switch. If your switch’s IP has not
been changed, it should have the following factory default value:
The switch’s Default IP
IP Address: 192.168.2.1
Subnet Mask: 255.255.255.0
Now if your computer’s IP is not in the same subnet as the switch, please follow the steps
below to change the computer’s IP:
Figure 4-1 Manual IP setting
17
AirLive POE-GSH2004L-370 User’s Manual
4. Web Management
Step 1. Double click on the network connection status icon on the task bar. This
should bring up a window showing the status of the current network
connection. If there is no network status icon on the task bar, please go to
the “Start -> Settings -> Network -> Local Connection” of the task bar’s
Start menu.
Step 2. Clock on the “property” icon.
Step 3. Double click on the “Internet Protocol (TCP/IP)
Step 4. Click on “Use the following IP address” button and enter the computer’s
address manually. This IP address must be on the same subnet as the
switch but different from the switch’s IP. Please make sure the IP is not
used by other network device. If the switch’s IP address is of factory’s
default value. We recommend enter the following for computer’s IP:
IP Address: 192.168.2.50
Subnet Mask: 255.255.255.0
Gateway: 192.168.2.1
Click “Ok” after finish entering the IP.
※Note1: The POE-GSH2004L-370 has DHCP client ability. This allows DHCP server (or
router) to assign IP automatically. However, we do not recommend turning on the DHCP
client because the DHCP server assign the IP randomly. The DHCP client should be used
only when connecting directly to Cable Modem (for remote management) whose service
provider uses DHCP for IP assignment.
Now, you will be able to access the switch by typing in the switch’s IP address on the web
browser.
AirLive POE-GSH2004L-370 User’s Manual
18
4. Web Management
4.2 Remote Management
In this section, you will learn how to setup your computer and the router for remote web
management. Remote management allows MIS to manage a switch from outside of the
switch’s IP domain or from Internet. Depending on the type of Internet connection you have,
there are two ways to setup the switch to be available through Internet.
Direct Connection to Internet
If you have a fixed IP xDSL account or cable modem account, and there is no router in the
network, you can connect your switch directly to Internet via xDSL modem/Cable Modem.
However, this method is not recommended as the LAN will be directly exposed to the
Internet.
Fixed IP: If your ISP has assigned you a fixed IP. Please go to the Switch’s IP
configuration and enter the IP address, Subnet Mask, and Gateway information offered
by your ISP. If your ADSL connection is PPPoE or PPTP type, you have to connect
through a router for remote management.
Cable Modem:If your Cable service provider uses DHCP for IP assignment, please
turn on the DHCP function under IP configuration. Make sure there is no DHCP server
in the network. Then the Cable provider will assign the switch with a IP and Gateway.
Go to the console port management to find out what IP has been assigned to the
switch.
When the configuration is finished, the Remote PC can access the switch by typing the
switch’s IP address on the web browser.
19
AirLive POE-GSH2004L-370 User’s Manual
Connect through Broadband Router
4. Web Management
If you have an IP sharing router in the network, you can open a virtual server on the router
to allow the switch to be managed through Internet. This method is more recommended as
the broadband router provides natural firewall protector from hackers.
In the diagram above, the router has the WAN (given by the ISP) port IP address
“201.100.1.5” and LAN port address “192.168.0.254”. The switch’s IP is “192.168.0.200”.
Please follow the instruction below to setup the router and switch for remote access:
On the Switch
On the IP setting, set the gateway to Router’s LAN port address 192.168.0.254.
Please make sure the subnet mask is the same as the router’s.
On the Router
Go to router’s Virtual Server setting and open the Web port (TCP Port 80) to the switch’s
IP address 192.168.0.200.
If your router require enter the beginning and ending Port (from PortX to PortX), enter
80 for both.
Now the Remote PC will be able to access your switch by entering “201.100.1.5” in the
Web browser’s address field.
AirLive POE-GSH2004L-370 User’s Manual
20
4. Web Management
4.3 Get Into the Web management
After you have properly configured the computer and switch’s IP, you can get into the web
management by the following steps:
Step 1. Open the Internet Explorer
Step 2. Enter the switch’s IP address in the Address field and press enter.
Step 3. When prompt for and Password, enter the following information:
Password: airlive
You should see the following welcome screen after the process is completed:
21
AirLive POE-GSH2004L-370 User’s Manual
Loading...
+ 60 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.