No part of this publication may be reproduced in any form or by any means, whether
electronic, mechanical, photocopying, or recording without the written consent of OvisLink
Corp.
OvisLink Corp. has made the best effort to ensure the accuracy of the information in this
user’s guide. However, we are not liable for the inaccuracies or errors in this guide. Please
use with caution. All information is subject to change without notice
All Trademarks are properties of their respective holders.
i
AirLive POE-FSH8PW User’s Manual
Copyright and Disclaimer
FCC Statement
Federal Communication Commission Interference Statement This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
z Reorient or relocate the receiving antenna.
z Increase the separation between the equipment and receiver.
z Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
zConsult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation. For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channels is not possible.
This device and its antenna(s) must not be co-located or operation in conjunction with any
other antenna or transmitter.
IMPORTANT NOTE
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
The POE-FSH8PW is a Power Control Passive POE Switch. It was designed for easy
installation and high performance in an environment where traffic is on the network and the
number of users increases continuously.
It consists of 8 PSE/PoE ports. That can solve the limitation of the power outlet location and
offer the system designer a flexible solution to locate the network device everywhere.
By the default, the PoE port's power is turned off, you must turn on the power through web
management. This switch does not work with 802.3af and 802.3at PoE devices, please
make sure your device's PoE port can accept 24V passive PoE power, and 12V passive
PoE kit will not work with this switch.
The compact rigid desktop size was specifically designed for small to medium workgroups.
It can be installed where space is limited; moreover, it provides smooth network migration
and easy upgrade to network capacity. The switch does not include the optional rack mount
kit, it must be purchased separately.
This user’s manual will help you to uncover most functions of the POE-FSH8PW with
step-by-step instructions presented by high quality illustrations. Thank you for choosing
OvisLink’s product.
1
AirLive POE-FSH8PW User’s Manual
1. Introduction
*Note:
This switch does not work with 802.3af and 802.3at PoE devices. It uses 24V passive
PoE standard
Please make sure your device's PoE port can accept 24V passive PoE power.
1.2 Guide to the Chapters
Chapter 1: Introduction and Quick Setup guide. All the essential information including
IP Address and Password information are in the Quick Setup section.
Chapter 2: Detail installation instruction including how to make Cat. 5 Cable
Chapter 3: LED indicators
Chapter 4: Detail information on Web management including how to setup remote
management.
1.3 Quick Setup
This section provides the essential information for experienced users to operate the switch
immediately. For detailed installation instruction, please see chapter 2 for more information.
Power-On the switch
The POE-FSH8PW has a built-in power supply to operate with 100 ~ 240V AC, 50 ~
60Hz power source.
The AC power cord connector is located at the rear of the unit and the On/Off switch is
next to the connector.
After the Switch is powered on, it will perform “self-diagnostic” test. This process takes
about 5 seconds to complete.
LED Table
LED Status Description
PoE On The POE function is enabled.
Off The POE function is disabled.
On Power is on. Power
Off Power is off.
Link/ACT
AirLive POE-FSH8PW User’s Manual
On Port is for connection.
Off No connection.
Flashing Data is transmitting or receiving
2
1. Introduction
1.4 Installation Steps
This section lists the installation procedures in steps. Each step’s instruction is thoroughly
explained in the subsequent sections of following chapter.
Step1. Connect your device's passive PoE port to the switch's LAN port
Step2. Connect your PC to the switch.
Step3. Set your PC's IP address to 192.168.2.50.
Step4. Open your web browser and enter "192.168.2.1" to get into the switch's web
management.
Step5. Enter "admin" for username and "airlive" for password.
Step6. Go to "Port Management", and then select "PoE".
Step7. Turn on the port number where you connect the device.
3
AirLive POE-FSH8PW User’s Manual
1. Introduction
Step8. If you want to install the switch on the 19" rack, please install the mounting kit
(optional).
Step9. Please see Chapter 4 for further configurations.
AirLive POE-FSH8PW User’s Manual
4
2. Installation of the Switch
2. Installation of the
2
This chapter provides the detailed instructions for installation of the switch. For concise
installation instruction, the previous chapter’s “Quick Setup” section provides all the
important information including IP address, password, and LED table for user’s reference.
Switch
2.1 Unpack the Package
Before you begin the installation of POE-FSH8PW Management Switch, make sure that
you have all the necessary accessories that come with your package. Follow the steps
below to unpack your package contents:
1. Clear out an adequate space to unpack the package carton.
2. Open the package carton and take out the contents carefully.
3. Put back all the shipping materials such as plastic bag, padding and linings into the
package carton and save them for future transport need.
After unpacking and taking out the entire package contents, you should check whether you
have got the following items:
POE- FSH8PW
One AC Power Cord
Quick Install Guide
Support CD-ROM (The PDF version of this User’s Manual can be found within)
If any of these above items is missing or damaged, please contact your local dealer for
replacement.
*Note: The switch does not include the optional rack mount kit, it must be purchased
separately
5
AirLive POE-FSH8PW User’s Manual
2. Installation of the Switch
2.2 Hardware Overview
Front Panel
The front panel of the web smart switch consists of 8 10/100Base-TX RJ-45 ports. The LED
Indicators are also located on the front panel.
LED Indicators:
Comprehensive LED indicators display the status of the switch and the network (see the
LED Indicators chapter below).
100BASE-TX Fast Ethernet PoE Ports (Port 1~8):
These ports are PoE enable ports. These PoE ports will be automatically activated when a
compatible terminal is identified, and the PoE port will supply power to the connected PoE
device.
For legacy devices that are not yet compatible, the PoE port will not offer the power to
these devices. This feature allows users to freely and safely mix legacy and Power over
Ethernet compatible devices on their network.
These ports support network speeds of either 10Mbps or 100Mbps, and can operate in halfand full- duplex transfer modes. These ports also support the automatic MDI/MDIX
crossover detection function, providing true “plug and play” capability. Just plug-in the
network cable to the hub directly and regardless if the end node is a NIC (Network Interface
Card) or switch and hub.
Reset:
The Reset button is to reset all the setting back to the factory default.
*Note: Be sure that you recorded the setting of your device, else all the setting will be
erased when pressing the “Reset” button.
AirLive POE-FSH8PW User’s Manual
6
2. Installation of the Switch
The Rear Panel
The 3-pronged power plug is placed at the rear panel of the switch right side shown as
below.
2.3 Installation Site Preparation
You can mount POE-FSH8PW either on desktop or on a 19-inch rack. If you plan to mount
the switch on desktop, please choose a steady, level surface in a well-ventilated area that
is free from excessive dust. In any case, the installation site chosen for your switch has to
comply with the following requirements:
The surface where you want to mount the switch must be able to sustain at least 1.5kg.
Do not place heavy objects (more than 3kg) on top of the switch.
The location must preferably be free from excessive dust, away from heat vent, hot-air
exhaust and direct sunlight.
The switch should not be placed near large electric motors or other strong
electromagnetic sources. As a reference, the strength of the electromagnetic field on
site should not exceed the (RFC) standards for IEC 801-3, Level 2(3V/M) field strength.
The air temperature in the location should be within a range of 0 to 65°C.
The relative humidity in the location should not exceed 90% non-condensing humidity.
The distance between the RJ-45 port and the standard network interface should not
exceed 100 meters.
Adequate space should be allowed in front of all the ports, so that each port is easily
accessible for cable connections.
Leave at least 10cm(4 inch) of space around the switch to allow heating dissipation
7
AirLive POE-FSH8PW User’s Manual
2. Installation of the Switch
2.4 Rack Mounting
The POE-FSH8PW can be mounted on a standard size 19-inch rack, which can in turn be
placed in a wiring closet with other equipments.
Before you can mount the switch on the rack, first you must attach the mounting brackets
on both sides of the switch with screws, and then mount it as a unit on the rack.
To mount the unit on a rack, please follow the steps below:
Step 1. First, align the holes on the bracket with the holes on both side of the switch.
Step 2. Insert screws into the holes and then fasten the bracket on one side of the switch
with a screwdriver.
Step 3. Repeat Step 1 and 2 to fasten the bracket on the other side of the switch.
Step 4. Mount the unit on the rack and align the notches on both brackets with mounting
holes on the rack, and then secure the unit with suitable screws.
Fastening the brackets on the switch
AirLive POE-FSH8PW User’s Manual
8
Attaching the Switch to a 19-inch rack
2. Installation of the Switch
2.5 Desktop Installation
The POE-FSH8PW has four rubber pads attached on each corner of its underside. These
pads serve as cushioning against vibration and prevent the switch from sliding off its
position. They also allow adequate ventilation space when you place the switch on top of
another device.
Desktop installation
The location you choose to install your switch and the way you configure your network
may greatly affect its performance. Please see the previous section for “installation site”
preparation.
Do not place more than 1.5kg (6.6lbs) of weight on the top of the switch.
Leave at least 10cm of space around the switch to allow proper heating dissipation.
9
AirLive POE-FSH8PW User’s Manual
2. Installation of the Switch
2.6 Cabling Requirements
For 100BASE-TX ports
The 8 RJ-45 station ports require Cat. 5 twisted-pair UTP/STP cable for connection. When
configuring within the 10/100 BASE-T cabling architecture, the cable distance should be
within 100m.
The following table summarizes the cable requirement for 10/100BASE-TX connection:
10BASE-T
100BASE-TX
100 ohm Category 3, 4, 5 UTP/STP cable
100 ohm Category 5 UTP/STP cable
Auto MDI/MDI-X function
The POE-FSH8PW is equipped with Auto-MDI/MDI-X function, which allows you to use
straight-thru cable even when connecting to another switch/hub. Simply use the
straight-through cable for all types of 10/100BASE-TX connections, either to a PC or to a
networking device such as other hub or switch.
Connection
Specification
Interface
Cable to Use
To an end station
To a hub/switch
Maximum Distance
RJ-45
Straight-through twisted-pair cable
Straight-through twisted-pair cable
100 meters
10 /100Base-TX
2.7 Connecting to Power
POE-FSH8PW features a universal auto-select power supply unit, which allows a power
connection to a wide range of input voltages from 100 to 240VAC @ 50 ~ 60Hz.
To establish its power connection, simply plug the female end of the power cord into the
power connector on the rear of the switch and the male end of the power cord into a
suitable power outlet. Once you have correctly plugged in the power, you can then turn on
the Power Switch to activate the switch.
AirLive POE-FSH8PW User’s Manual
10
2. Installation of the Switch
2.8 Reset to Default
When you forgot your IP or password, please use the reset button for the factory default
setting? Please take the following steps to reset the Web Smart Switch back to the original
default:
Step 1. Turn on the POE-FSH8PW.
Step 2. Press and hold the reset button continuously for 10 seconds and release
the reset button.
Step 3. The switch will reboot for 5 seconds and the configuration of switch will
back to the default setting.
Key in the user ID and the password to pass the authentication; the default ID and
Password is as below,
IP Address: 192.168.2.1
ID: admin
Password: airlvie
11
AirLive POE-FSH8PW User’s Manual
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.