Air-King FRAK90 User Manual

SPECIFICATIONS
FRAK90
EXHAUST FAN
90 CFM/1.5 Sones @ 0.10" SP. 73 CFM @ 0.25" S P.
• Grill
Cold rolled steel, powder coated white.
• Blower Wheel
One piece polymeric centrifugal blower wheel, 51/4" diameter, 27/8"
wide, with 30 paddles.
• Motor
Heavy duty, permanently split capacitor, 4 pole motor, life time
lubrication, thermally protected, suitable for continuous operation. Rated 120 volts.
Contractor Pack (Motor/BladeGrill) Model: FAK90T*
• Fan Housing
24 gauge galvanized steel housing, dimensions 103/4" x 91/4" x 77/8".
Contractor Pack Model: AKFH2*
• Duct Collar
Metal collar for 4" duct connection, comes complete with built in
back draft damper.
• Unit Mounting
FRAK90 is centered between joists (with 16" centers) using hanging
brackets. The housing will mount through drywall thickness up to
3
/4", with a rough-in opening of 103/4" x 91/4".
* Sold in packs of 4. All three parts
be purchased and used together to make a complete unit.
• Damper
Blanket - Non-asbestos, ceramic blanket Fusible Link - Replaceable, 165°F standard Classification - CUL Listed 555C and 263. California State Marshall
classification for 3 hour fire damper rating. California State Marshall listing number 3226-1721:0109.
Contractor Pack Model: AKFD2*
(housing, damper, motor/blade/grill) must
7
8
7
/
"
5
8
/
"
10
Acceptable for use over tub or shower when installed in a GFCI protected branch circuit.
9
5
16
/
1
4
/
"
"
COMPLIES WITH
ASHRAE
62.2
T
A
L
I
T
N
V
E
N
A
T
S
N
O
I
3
10
/
15
16
12
/
S
D
R
A
D
• Ventilating Area
For bathrooms up to 115 sq. ft.
• Wood Frame Truss Design Listings
cETLus: L501, L502, L503, L506, L507, L508, L512, L513,
cULus: L501, L502, L503, L506, L507, L508, L512, L513,
L514, L515, L516, L517, L519, L521, L522, L523, L528, L530, L533, L537, L545, L546, L550, L562, L563,L570, L574, L579, L581, L583, L585, L586, M503, M530, M538, P522, P531, P538, P545, P552
L514, L515, L516, L517, L519, L522, L523, L533, L537, L545, L581, L583, M530, M538
4
"
4"
"
EXPANDED PERFORMANCE
Sones Fan Speed Maximum Static Pressure (inches of w.g.) @ .1 SP RPM Fan Watts Amps
0 0.05 0.1 0.125 0.15 0.2 0.25 Air Flow - CFM 101 94 90 88 86 80 73 1.5 1250 26.0 0.30
PROJECT
LOCATION
CONTRACTOR
FAN MODEL NUMBER NUMBER W.G. & REMARKS
Specifications subject to change without notice.
IN
CFM
RPM WATTS AMPS SONES QTY
N
A
I
N
A
I
M
M
E
E
E
E
D
D
R
R
A
A
I
I
C
C
M
M
S
S
T
T
E
E
E
E
M
M
R
R
E
E
Q
Q
U
U
I
I
R
R
E
E
M
M
E
E
A
A
A
A
N
N
R
R
T
T
R
R
S
S
A
A
O
F
O
F
ARCHITECT
SUBMITTED BY DATE
OPTIONAL EQUIPMENT
U.S.: 820 Lincoln Avenue
West Chester, Pennsylvania 19380-4466 Tel: (610) 692-7400 • 877-304-3785 Fax: (610) 696-8048
Canada:
Brampton, Ontario Tel: 905-456-2033 Fax: (905) 456-1015
Updated 12-18
Loading...