RY-24L
Form C Door Release Relay for AX, KB, KC, and JA Color Video Systems
- INSTRUCTIONS -
The RY-24L Door Release Relay Module is an interface between the door release contact on the Aiphone monitor and the
actual release mechanism. The contact closure directly out of the monitor is rated at 12V AC with a low current capacity. If
your strike or maglock requires more voltage or current, the RY-24L is required. It provides either a Normally Open contact
for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating supports a majority of door
release hardware available on the market. The RY-24L relay is recommended with all AX, KC, KB, and JA video systems
when using the door release feature. This will protect the built-in contact from possible surge damage.
(Note: For more than one door release on the KB system, use the RY-3DL.)
INSTALLATION:
1. Install in a suitable location, either near the power source for the door release mechanism, or behind the monitor.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
4. Trim the unused contact wire so the bare strands are not exposed.
WIRING DIAGRAMS:
JA System Wiring
JA-2MECD
JA-2MCD
RED: L/ORG
BLK: (-) Neg.
BRN: Common
ORG: N/O
YEL: N/C
RY-24L COLOR CODE:
Input of Relay:
Red: L/ORG, Postive trigger
Black: (-) NEGATIVE
Output of Relay:
Brown: COMMON
Orange: N/O Contact
Yellow: N/C Contact
(See contact rating specs on
back page)
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
MAGNETIC LOCK
WIRING METHOD:
(Normally Closed contact)
Door
Release
Door
Release
#2
#1
Door 2
JA-DAC
LOCK
POWER
Door 1
JA-DAC
LOCK
POWER
RY-24L
A1
A2
Brn
Org
Yel
RY-24L
A1
A2
Brn
Org
Yel
Blk
Red
COM
N/O
N/C
Blk
Red
A1
A2
A1
A2
C1
C2
C1
C2
#1
Purp
Blu
Grn
Yel
Org
Red
Brn
#2
L1 (Brn)
L1 (Red)
L2 (Org)
L2 (Yel)
B1
SUB
B2
DOOR 1
DOOR 2
1
ADAPTER
2
ADAPTER
PS-2420UL
+
-
+
-
Connect RED and
YELLOW wire on
JA--2MCD/-2MECD
directly to +
NOTE: The door release contacts are rated at 24V AC, 500mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the JA monitor could result.
Page 1
WIRING DIAGRAMS (cont):
KB & KC System Wiring
Master
KB-3MRD
KB-DAR
MAGNETIC LOCK
WIRING METHOD:
(Normally Closed contact)
LOCK
POWER
-
+
+
-
Use Brown & Yellow wires
when connecting to Maglock.
Brn
Org
Yel
A1
A2
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
LOCK
POWER
To (-) of
power supply
Blk
COM
N/C
Red
Connect Red
to Orange
lead of Master
Brn
Org
Yel
Blk
Red
1A1
1A2
2A1
2A2
3A1
3A2
CN11
Org
Yel
KC-1GRD
KC-1MRD
B1
B2
PS-2420UL
+
-
YELLOW
wire of CN11
directly to +
+
-
Connect
on unit.
KC-DAR
A1
A2
1A1
1A2
B1
B2
+
-
PS-2420UL
+
-
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Brn
Org
Blk
Red
COM
N/O
Yel
Org
S
S
Yel
LOCK
POWER
NOTE: The door release contacts are rated at 12V AC, 400mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the KB/KC monitor could result.
Connect
YELLOW
wire of CN11
directly to +
on unit.
Page 2