Aiphone PT-1610 User Manual

PT-1610 Mounting Instructions
16V AC, 10VA Transformer
INSTRUCTIONS
MOUNTING ON A METAL BOX:
1. Secure gang box to wall or ceiling stud.
2. Remove a conduit knockout from the gang box.
3. Pass transformer wires through knockout hole to inside of box. (Locking screw must be removed to pass flange through hole.)
4. Secure transformer to box with locking screw of appropriate length. Two screws are provided.
5. Connect incoming AC power to two BLACK wires. Connect GREEN wire to ground.
16V AC Output
PT-1610
Transformer
Locking
Mounting Flange
MOUNTING IN A PLASTIC TWO GANG BOX
1. Secure gang box to stud.
2. Open a plastic locking tab from the gang box.
3. Pass AC wires through hole to inside of box.
4. Connect incoming AC power to two BLACK wires. Connect GREEN wire to ground.
5. Connect low voltage AC power to the two screw terminals.
6. Run low voltage wire through a different locking tab then to the 110V AC wires.
8. Locate transformer inside the box, then cover with a blank plastic faceplate.
120V AC
Gang Box
Screw
PT-1610
Transformer
Gang Box
16V AC Output
SAMPLE WIRING DIAGRAM (1 Master 1 Door):
CC-DA
CC-1M
Red
Brown
SAMPLE WIRING DIAGRAM (2 Masters, 1 door) :
CC-DA
Red
Brown
PT-1610
CC-1M
Red
Brown
Red
Brown
~ ~
White White
CC-1M
Red
Brown
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
~ ~
PT-1610
TOLL FREE TECHNICAL SUPPORT:
White White
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: tech-serv@aiphone.com
~ ~