Installation Manual
IX-SS-2G (Audio Only Door Station)
Issue Date: Oct. 2018 FK2455 B P1018 MQ 60409
Introduction
• Read this manual before installation and connection.
Read the "Setting Manual" and "Operation Manual". The manuals can be downloaded from our
homepage at "https://www.aiphone.net/product/support/" free of charge. (The manuals will be
available from 9 November 2018 onwards.)
• After completing installation and connection, program the system according to the “Setting Manual”.
The system cannot operate unless it is programmed.
• After performing installation, review with the customer how to operate system. Leave
documentation accompanying the Master Station with the customer.
Perform installation and connection only after gaining sufficient understanding of the
system and this manual.
The illustrations used in this manual may differ from the actual stations.
Example of System Configuration
PoE switch
(third party)
PoE switch
(third party)
LAN
PoE switch
(third party)
Part Names and Accessories
IX-SS-2G Included accessories
Front view Back view
Call indicator (Green)
Speaker
Microphone
Call button
Status indicator
(Orange/Blue)
Communication indicator
(Orange)
* Accessible when terminal cover is opened
MAC address
LAN port *
Reset button *
Low-voltage line connection
terminal *
Terminal cover
Installation Manual ×2
(English, Japanese)
Special screws
×4
Precautions
Product
warranty
(Japanese) ×1
Special screwdriver
×1
Notice
(IX Manuals and
Software) ×1
PoE switch
(third party)
PoE switch
(third party)
Network video
recorder
(third party)
Network camera
(third party)
PoE switch
(
third party
Status Indicator
Refer to "IX-SS-2G Operation Manual" for additional indicators not listed below.
Orange
flashing
Blue light
Normal flashing
0.75 sec0.75 sec
Rapid flashing
0.25 sec0.25 sec
Long interval flashing
0.5 sec4 sec
Long irregular flashing
Short irregular flashing
Status (pattern) Meaning
PoE switch
(
)
third party
Booting
Device error,
Startup error
Communication
failure
Firmware version
updating
Initializing
Standby
)
: Lit : Off
Warning
Negligence could result in death or serious injury.
Do not disassemble or modify the
device.
May cause fire or electrical shock.
Do not, under any circumstances,
open up the device.
Voltage within some internal
components may cause electrical
shock.
Caution
Negligence could result in injury to people or damage to
property.
Do not install or connect the
device with the power on.
May cause electrical shock or
malfunction.
Do not turn on power without first
checking to make sure the wiring
is correct and there are no
improperly terminated wires.
May cause fire or electrical shock.
The device is not designed to
explosion-proof specifications.
Do not install or use in an oxygen
room or other such locations
filled with volatile gases.
May cause fire or explosion.
Do not put your ear close to the
speaker when using the device.
May cause harm to the ear if a
sudden loud noise is emitted.
General Precautions
• Install low-voltage lines at least 30cm (11") away from high-voltage lines (AC100V, 200V), especially inverter
air conditioner wiring. Failure to do so may result in interference or malfunction.
Notice
• The illustrations and images used in this manual may differ from the actual items.
• If the device is used in areas where there are business-use wireless devices such as a transceiver or mobile
phones, it may cause malfunction.
• If the device is installed close to a light dimmer, an inverter electrical appliance or the remote control unit of a
hot-water system or floor-heating system, it may create interference and cause a malfunction.
• If the device is installed in an area with an extremely strong electrical field, such as in the vicinity of a
broadcasting station, it may create interference and cause a malfunction.
Precautions for mounting
• Installing the device in the following locations could cause malfunction:
- Locations that get hot
Close to a heater, boiler, etc.
- Locations where there is risk of exposure to liquid, dust, oil, or chemicals
- Locations with high humidity
Bathroom, basement, greenhouse, etc.
- Locations with low temperature
Inside a cold storage warehouse, the front of a cooler, etc.
- Locations directly exposed to steam or oil smoke
Next to heating devices or a cooking space, etc.
- Sulphurous environments such as a hot spring area
- Locations close to the sea or directly exposed to sea breeze
• If existing wiring is used, the device may not operate properly. In that case, it will be necessary to replace the
wiring.
• Do not, under any circumstances, use an impact driver to fasten screws. Doing so may cause damage to the
device.
How to Install
Coaxial cableParallel cable
Installation of Audio Only Door Station
When installing the unit on a rough surface, please use sealant to seal the unit edges to prevent water entering the unit. If the unit edges are left unsealed on a rough
surface, IP65 ingress protection rating is not guaranteed.
■ Connection and disconnection of low-voltage lines
• Insert the line into the quick connection terminal.
• If the line does not go in easily, push the low-voltage line into the terminal while pressing down the detachment button.
• When removing a low-voltage line, pull on the line while pressing down the detachment button.
8mm (5/16")
Open the terminal cover and connect the
Cat-5e/6 cable and the low-voltage lines to
the unit.
Slide the terminal cover down.
①
Open the terminal cover.
②
Route the wires through inlet.
③
Insert the low-voltage lines and Cat-5e/6 cable, and replace the terminal cover.
④
Be sure to close the terminal cover when done.
If left open, condensation or water may enter, preventing heat
dissipation and causing damage.
Unit
2
Attach the door station.
Loosen
Special screwdriver
(included)
Tighten
How to Connect
Special screws (included) ×4
Inlet
Cat-5e/6 cable
Low-voltage lines
2-gang box
(Depth: 52.5mm(2-1/16") or more)
Recommended
Mounting height
(center of gang box)
1,350 mm (4' 5'')
(max.1,900 (6' 2-2/3"))
Wiring Connection
• Insulate and secure unused low-voltage lines.
Cat-5e/6straight
PoE switch
※
IEEE802.3af
LAN/PoE
100m (330')
Detachment
button
Recommended
diameter of wire
ø0.8
* The shape varies depending on a model.
Audio Only Door Station
IX-SS-2G
※
N
O
C
N
O
C
M
S
S
E
PE0.8(20AWG)-2C
PE0.8(20AWG)-2C
Contact input
Relay output
※1
※2
Connection Precautions
■ Cat-5e/6 cable
• For connection between devices, use a straight-through cable.
• If necessary, when bending the cable, please observe the manufacturer’s recommendations. Failure to do so could cause a communication failure.
• Do not strip away the cable insulation any more than is necessary.
• Perform termination in accordance with TIA/EIA-568A or 568B.
• Before connecting the cable, be sure to verify conduction using a LAN checker or similar tool.
• A RJ45 covered connector cannot be connected to the LAN ports of the master stations or the door stations. Use cables without covers on the connectors.
• Be careful not to pull on the cable or subject it to excessive stress.
■ Precautions regarding low-voltage line
• Use PE (polyethylene)-insulated PVC jacketed cable. Parallel or jacketed conductors, mid-capacitance, non-shielded cable is recommended.
• Never use twisted-pair cable or coaxial cable.
• 2Pr quad V twisted pair cables cannot be used.
※1 Contact Input Specifications
Input method Programmable dry contact (N/O or N/C)
Level detection method
Detection time 100 msec or more
Contact resistance Make: 700 Ω or less
Break: 3 kΩ or more
Terminal short-circuit current 20 mA or less
Voltage between terminals 5.5 VDC or less (between open terminals)
※2 Relay Output Specifications
Output method Form C dry contact (N/O or N/C)
Contact rating 24 VAC, 1 A (resistive load)
24 VDC, 1 A (resistive load)
Minimum overload (AC/DC): 100 mV, 0.1 mA