IS-IP4DVF
IP Video Door Station with 4 Call Buttons
-INSTRUCTIONS-
The IS-IP4DVF is an IS Series IP video door station with 4 call buttons for selective calling. The
IS-IPRY8 adaptor is required for assigning the call buttons to specic master stations within the IS-IP
conguration (refer to the IS-IPRY8 programming manual for programming instructions).
The IS-IP4DVF will connect to a network switch, and the call buttons will connect to the IS-IPRY8
adaptor inputs.
IS-IP4DVF
PACKAGE CONTENTS:
NAMES & FUNCTIONS:
1. Camera 5. Directory card
1
2
2. Microphone 6. Call status indicator
3. LED illuminator 7. Call buttons with integrated
4. Speaker name placard
3
4
5
6
FEATURES:
• IP video door station
• 4 call buttons for selective calling to master stations
(IS-IPRY8 adaptor required)
• LED call status indicator
7
• 5 name placards
• Stainless steel faceplate with tamper resistant screws
INSTALLATION:
IS-IP4DVF
4 Call Button
Door Station
SA-1 x 3
Security Driver
Blank name
placard x5
Flush backbox &
tamper resistant screws
• For ush mounting, cut a hole in the wall and use the
supplied back box.
Box dimensions are: 11-3/4” H x 5-13/16” W x 1-3/4” D
• For surface mounting, use the SBX-ISDVFP surface
mount box. This box can mount to a standard 1 gang
box or to any at surface.
Note:
When installing the IS-IP4DVF in the supplied back box, the call
button assembly may come loose. Push call button assembly
back in to position as necessary.
Pg. 1
WIRING DIAGRAM:
IS-IPMV IS-IPMV
IS-IP4DVF
IS-IPMV
CAT-5e
CAT-5e CAT-5e
CAT-5e
IS-IPMV
Back View
CAT-5e
NO
COM
NC
To Strike
& Power
SA-1 modules are included to protect the
IS-IPRY8 adaptor from surge. Locate the
SA-1 modules near the IS-IPRY8 adaptor
and connect the ground terminal on each
SA-1 to an earth ground.
CAT-5e
~
~
~
SA-1 SA-1 SA-1
~
~
I1
I2
I3
I4
G
G
~
-
+
Power
IS-IPRY8
Note: Refer to the IS-IPRY8
Programming Manual for
information on programming
the adaptor.
PROGRAMMING:
The IS-IP4DVF door station must be set as a host or client device like any other IS-IP door station or master
station. The unit must be registered to the IS-IP system before it can be programmed to call a master station
using the call buttons and IS-IPRY8 adaptor. Refer to Steps 5-7 in the IS Series IP Direct System Programming
Guide for information on setting client and host devices and registering IP stations.
SPECIFICATIONS:
Camera unit: CMOS camera
Scanning line: 525 lines
Min. illumination: 5 Lux at 1’6”
Terminations: RJ45 jack for audio/video
Screw terminals for door release and call buttons
Operating Temp: 14° ~ 140°F / -10° ~ 60°C
Wiring Distance: 328’ with CAT-5e/6 cable to switch
Dimensions: 12-3/8” H x 7” W
w/SBX-ISDVFP: 12-7/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
• For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
• Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Aiphone Corporation
1700 130th AVE NE
Bellevue, WA 98005
(425) 455-0510
Fax: (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
E-MAIL: tech@aiphone.com
Pg. 2
IS-IP4DVF Instr.
0313JD