IS-DVF-2RA-FR
Stainless Steel Flush Mount Video Door Station with
Standard & Emergency Call Buttons
-INSTRUCTIONS-
The IS-DVF-2RA-FR is a stainless steel ush mount video door station with standard and emergency
call buttons. The unit is equipped with signage in French for both the standard and emergency
buttons. A call status indicator is included to meet rescue assistance requirements.
The IS-DVF-2RA-FR must connect to the IS-CCU or IS-SCU control units.
IS-DVF-2RA-FR
8
9
PACKAGE CONTENTS:
NAMES & FUNCTIONS:
1. Camera 6. Call status indicator
1
2
3
2. Microphone 7. French Signage
3. LED Light 8. Call button
4. Speaker 9. Emergency button
5. Name Placard
4
5
6
FEATURES:
• Audio communication with visual indentication
of calling area
7
• Two call buttons: Standard and Emergency
• LED call status indicator
• CCTV input
• Red mushroom button for emergency call
• Two programmable relay outputs for activation
of external systems/devices
• Name placard
• Stainless steel faceplate with tamper resistant
screws
Vandal-resistant Door Station
STEADY GREEN INDICATES CALL ANSWERED
IS-DVF-2RA-FR
Blank name
placard
CALL
EMERGENCY
Security Driver
Semi-ush backbox &
tamper-resistant screws
INSTALLATION:
• For ush mounting, cut a hole in the wall and
use supplied back box.
Box dimensions are:
11-1/16” H x 5-13/16” W x 1-3/4” D
• For surface mounting, use the SBX-ISDVFRA
surface mount box. This box can mount to a
standard 1-gang box or to any at surface.
Pg.1
WIRING DIAGRAM:
OFF ON
NO
NO
C
NC
C
NC
1234
IS-MV
IS-CCU
IS-DVF-2RA-FR
NO
COM
NC
N/O Dry Contact
OFF ON
1234
NO
C
NC
NO
C
NC
Board on back of unit
See wiring below
0.5 Amp
RELAY BOARD WIRING AND SETTINGS:
Conguration Switch
See Settings to right
Relay 1 Output
N/O, COM, N/C
Relay 2 Output
N/O, COM, N/C
*Relay 2 External Reset
Connect to N/O dry switch
CAT-5e
IS-PU-UL
CAT-5e
Default Conguration when shipped
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on emergency call and remains on during communication.
1 2 3 4
ON
Trigger Source RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
RY1 Remains ON
During Talking?
YES
YES
YES YES
NO N/A
YES
YES
RY2 Triggered?
RY2 Remains ON
During Talking?
NO
YES YES NO
NO
NO
N/A
N/A
N/A
Optional Conguration
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on an emergency call and remains on during communication. Relay 2 requires reset.
1 2 3 4
ON
Trigger Source RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
RY1 Remains ON
During Talking?
YES
YES
YES
NO N/A
YES
YES
YES
RY2 Triggered?
RY2 Remains ON
During Talking?
NO N/A
YES YES
NO
NO
N/A
N/A
N/A
Contact Technical Support if additional switch congurations
are required.
RY2 Requires
Reset?
N/A
N/A
N/A
RY2 Requires
Reset?
YES*
N/A
N/A
SPECIFICATIONS:
Camera unit: CMOS camera
Scanning line: 525 lines
Min. illumination: 5 Lux at 1’6”
Terminations: RJ45 jack for audio/video
Screw terminals for door release and relay outputs
Relay rating: 24V AC/DC 0.5A on Door station, 24V AC/DC 1.0A on relay board
Operating Temp: 14° ~ 140°F / -10° ~ 60°C
Wiring Distance: 980’ with Cat5e/6 cable
Dimensions: 11-3/4” H x 7” W
w/SBX-ISDVFRA: 11-11/16” H x 7-1/16” W x 2-13/16” D (top), 1-13/16” D (bottom)
Pg. 2
IS-DVF-2RA-FR Instr.
0716
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
• For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
• Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
www.aiphone.com
tech@aiphone.com
(800) 692-0200