Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation,
and keep it in a safe place for future reference.
Also read the SETTING MANUAL and OPERATION MANUAL on the bundled CD-ROM.
When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non-
functional.
IMPORTANT
•
Do not install the system until you have completely understood the system and this manual.
•
The system must be installed and wired by a qualifi ed technician well-versed in network construction.
Please note that the illustrations in this manual may differ from the actual ones.
After unpacking, check the included parts for each product
referring to the corresponding pages.
ABOUT THIS MANUAL
The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your
system.
Manual confi gurations
The following manuals are provided for a local system. Read all the manuals for installing, setting up, and using a local system, or
provide the manuals to the persons working with the system.
* The INSTALLATION MANUAL includes the contents for a standard (IP) system.
INSTALLATION MANUAL (This manual)
Used for installing and connecting control units, stations and power supply unit. (For an installer or serviceman)
SETTING MANUAL (An electronic manual on the CD-ROM included with the central control unit)
Used for making the system settings and system maintenance. (For an installer or serviceman)
OPERATION MANUAL (An electronic manual on the CD-ROM included with the central control unit)
This manual describes how to use this system for calling, communicating, paging, monitoring, etc. (For users of the
system)
2
PRECAUTIONS
General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water
General Precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could
result.
2. Keep the unit away from water or any other liquid.
Fire or electric shock could result.
3. High voltage is present internally. Do not open the case.
Electric shock could result.
4. The unit is not of explosion-proof. Do not install or use near
gases or fl ammable materials. Fire or explosion could result.
5. Do not connect any non-specifi ed power source to the +, -
terminals. Also, do not install two power supplies in parallel to a
single input. Fire or damage to the unit could result. Be sure to
connect a single power supply unit to a control unit.
6. Do not connect any terminal on the unit to an AC power line.
Fire or electric shock could result.
7. Do not use power supply with a voltage other than specifi ed.
Fire or electric shock could result.
8. Keep AC cord from being marred or crushed. If the AC cord is
fractured, fi re or electric shock could result.
9.
Do not plug or unplug with wet hands. Electric shock could result.
10. Insert AC plug completely and securely into AC outlet.
Otherwise, fi re or electric shock could result.
11.
Do not put any metal or fl ammable material into the unit through
the openings. Fire, electric shock, or unit trouble could result.
12. The unit must be installed and wired by a qualifi ed technician.
13.
Existing wiring such as chime wiring, etc. may contain high voltage
AC electricity. Damage to the unit or electric shock could result.
Wiring and installation should be done by a qualifi ed technician.
CAUTION
Negligence could result in injury to people or damage to property.
1.
Do not install or make any wire terminations while power supply
is plugged in. It can cause electrical shock or damage to the unit.
2. When mounting the unit on a wall, install the unit in a
convenient location, but not where it could be jarred or
bumped. Injury could result.
3. Before turning on power, make sure wires are correctly
connected, not crossed or not shorted. If not, fi re or electric
shock could result.
4.
Do not install the unit in locations subject to frequent vibration or
impact. It may fall or tip over, resulting in damage to the unit or
personal injury.
5. For power supply, use Aiphone power supply model or model
specifi ed for use with system. If non-specifi ed product is used, fi re or malfunction could result.
6. On products with ground terminals, connect to an earth ground.
Fire or malfunction could result.
7. For DC powered systems, use Aiphone power supply model
specifi ed with system. If non-specifi ed product is used, fi re or
malfunction could result.
8. Do not put high pressure on the monitor. If fractured, injury
could result.
9. If LCD is punctured, do not allow contact with the liquid crystal
inside. Infl ammation could result. If necessary, gargle your
mouth and clean your eyes or skin with clear water for at least
15 minutes, and consult your doctor.
10. Do not put anything on the unit or cover the unit with cloth, etc.
Fire or unit trouble could result.
11. Do not install the unit in any of the following locations. Fire,
electric shock, or unit trouble could result.
Places under direct sunlight or places near heating *
equipment that varies in temperature.
Places subject to dust, oil, chemicals, hydrogen sulfi de (hot *
spring).
Places subject to moisture and humidity extremes, such as *
bathrooms, cellars, greenhouses, etc.
Places where the temperature is quite low, such as inside a *
refrigerated area or in front of an air conditioner.
Places subject to steam or smoke (near heating or cooking *
surfaces).
Where noise generating devices such as dimmer switches or *
inverter electrical appliances are closeby.
12. Be sure to perform a call test or check the volume with the
handset on the hook. If you operate the hook switch with the
handset on your ear, a sudden call etc. may arrive causing
damage to your ear.
GENERAL PRECAUTIONS
1. Keep the unit more than 1 m (3.3') away from radio or TV.
2. Keep the intercom wires more than 30cm (12'') away from AC
100-240V wiring. AC induced noise and/or unit malfunction could
result.
3. Install the unit in an area that will be accessible for future
inspections, repairs, and maintenance.
4. As to other manufacturer’s devices (such as sensor, detectors,
door releases) used with this system, comply with the
Specifi cations and Warranty conditions that the manufacturers or
venders present.
5. If the unit is down or does not operate properly, turn off the power
switches and unplug the power supply.
6. If it is used close to a cellular phone, the unit may malfunction.
7. The unit can be damaged if dropped. Handle with care.
8. The unit turns inoperative during power failure.
9. In areas where broadcasting station antennas are close by, the
intercom system may be affected by radio frequency interference.
10. All the units, except for door station, is designed for indoor use
only. Do not use outdoor.
11. This product, being a control unit of door release, should not be
used as a crime prevention device.
12. It must be noted in advance that the LCD panel, though
manufactured with very high precision techniques, inevitably will
have a very small portion of its picture elements always lit or not lit
at all. This is not considered a unit malfunction.
13. Door station is weather-resistant, but do not spray with highpressure water. Unit trouble could result.
14. For wiring, specify CAT5e/6 straight cable.
15. Due to the environmental sound around the unit, it may hinder
smooth communication, but this is not a malfunction.
16. When outside temperature lowers sharply after rainfall, etc., the
inside of camera may fog up slightly, causing a blurry picture, but
this is not a malfunction. Normal operation will be restored when
moisture evaporates.
17. Do not locate the units in a location with restricted access. It
impedes maintenance inspection or repairs. Also, unit trouble
could result.
3
Notes on using this system
The ID/Password to access the web server for setting the system
•
is the customer's responsibility. Make sure you set a password that
cannot be easily guessed by a third party. We recommend that you
change the ID/Password on a regular basis.
Notices
We will under no conditions be liable for damage that occurs due
•
to failures in network equipment; failures due to internet providers
and cell phone companies; failures such as disconnected lines and
other losses in communication, which render it impossible to provide
this service or in any way delay this service due to causes outside
of our responsibility; or if an error or missing data occurs during
transmission.
We will under no conditions be liable for damage that occurs due
•
to the inability to communicate due to malfunctions, problems, or
operational errors in this product.
We will under no conditions be liable for damage caused if a
•
customer's password or transmitted information are leaked through
bugging or unlawful computer access over Internet communication.
We will under no conditions be liable for any damages or losses
•
resulting from this product's contents or specifi cations.
This manual was created by Aiphone Co., Ltd., all rights reserved.
•
Copying a part of or this entire manual without prior permission from
Aiphone Co., Ltd. is strictly forbidden.
Please note that images depicted in this manual may differ from the
•
actual images.
Please note that this manual may be revised or changed without
•
prior notice.
Please note that product specifi cations may be changed for the sake
•
of improvement without prior notice.
Please be aware that it is the customer's responsibility to ensure that
•
their computer is secure. We will under no conditions be liable for
security failures.
This system is not intended for life support or crime prevention. It is
•
just a supplementary means of conveying information. Aiphone will
under no conditions be liable for loss of life or property which occurs
while the system is being operated.
SYSTEM CONFIGURATIONS
The IS system is a commercial and security video intercom system especially designed for applications in facilities such as offi ce
buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications
systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system,
urgent call system, public announcement system, and access control system.
The IS system can be constructed on an IP network so multiple sites of IS system can be connected and controlled as a global
system. You can design the system to any scale depending on your needs.
Entire system
An entire system can have up to 32 sites connected on an IP network. In this system, calling, communication, etc. are possible among
sites.
Site 1
Site 2
Site 32
Site 3
Site 4
4
System confi guration examples
Standard (IP) system
■
The following is an example of standard (IP) system for controlling security and communication for facilities.
A site must be confi gured with an IP-based system.
•
A standard (IP) system can consist of local systems and IP units.
•
A local system (Hard wired network system) without connecting to an IP network can also be an independent system.
•
When using a local system as an independent system, it needs at least one central control unit (IS-CCU). To connect a local system
•
to a standard (IP) system, one IP control unit (IS-IPC) is needed.
An IP unit (PC master station, IP door station or IP master station) can be connected directly to a LAN.
•
In a site, up to 32 IP units (including up to 8 IP control units) can be connected.
•
Telephone
Site 1
: Control offi ce, etc.
IP
PSTN / private line (North America only)
Internet / WAN
Standard (IP) system
IS-RCU
IS-RCU
Site 3
Site 2
PBX telephone
LAN (IP network)
IPIPIP
IS-IPC
IS-CCU
IS-RCU
IS-RCU
Building 1Building 2
IS-SCUIS-SCU
IS-IPC
IS-CCU
IS-RCU
IS-IPC
IS-RCU
Building 3
Site 32
Building 4
IP
IPIP
Local system
This is also a local
system, however no
communication can be
made on this system
without connecting
with an IP network.
IP
:
IP unit
5
CONNECTIONS
System connection diagram
The following is an example of standard (IP) system connection diagram.
Refer to page 9 to 26 for details about each unit connection.*
To Internet/WAN
Broadband
router
Local system
PA speaker
PA speaker
Timer
CD player
PA amplifi er
PA amplifi er
IP
IS-CCU
(Max. 30)
IS-RS
PBX / Telephone
IS-IPC
IS-RCU
Switch (Hub)
*1
IS-PU-UL
or
IS-PU-S
and
/or
(Max. 4)
IS-SS
(Max. 1)
IS-PU-UL
IS-PU-S
IS-PU-UL
or
IS-PU-S
or
IS-MV
(Max. 8)
IS-MV
IS-DV/IS-DVF
/IS-SS
(Max. 4)
IS-SCU
(Max. 4)
and
/or
(Max. 2)
IS-PU-UL
or
IS-PU-S
(Max.8)
IS-DV/IS-DVF
/IS-SS
IS-RS
PT
AC
transformer
PA amplifi er
IS-RS
and
/or
Monitor
Recorder
PA speaker
EL-12S
Electric door
strike
8Ω speaker
Call button
Strobe light
*1: An IP control unit (IS-IPC) is needed to connect a local system to a standard (IP) system.
6
Monitor
Recorder
AC
PT
transformer
EL-12S
Electric door strike
Telephone network
LAN (IP network)
: IS system product
: IP unit
IP
Switch (Hub)
IS-SS
and
/or
Strobe light
(Max. 1)
IP
PC master station
(IS-SOFT)
Switch (Hub)Switch (Hub)Switch (Hub)
IS-IPMV
IP
PS-2420/D/UL/S*
PoE
Recorder
2
or
IS-IPDV
/IS-IPDVF
IP
PS-2420/D/UL/S*
AC
PT
transformer
EL-12S
Electric door strike
or
PoE
Local system
2
PA speaker
IP
PA amplifi er
8Ω speaker
PBX / Telephone
IS-IPC*
(Max. 30)
IS-RS
1
IS-RCU
Call button
*2: Do not use PS-2420S in Europe.
Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system"
CategoryModel nameType
Local system Standard (IP) system
IS-CCUCentral control unit18
Control unit
IS-SCUAdd-on control unit216
IS-RCURoom sub control unit432
Vandal-resistant video door station
Vandal-resistant video door station
*3
*3
Vandal-resistant audio door station (fl ush-mount)
Room sub station120960
(surface-mount)
(fl ush-mount)
Control unitIS-IPCIP control unit-
Master station
IP
Sub station
3
: You can use vandal-resistant audio door stations (IS-SS) instead of room sub stations (IS-RS) and vice versa.
*
4
: Up to 8 IP control units (IS-IPC) can be connected with an IP network per site. If you do so, the maximum number of other IP units that can be
*
IS-IPMVColor monitor IP master stationIS-SOFT (PC master station) PC master stationIS-IPDV
IS-IPDVF
IP vandal-resistant video door station (surface-mount)
IP vandal-resistant video door station (fl ush-mount)
connected to the IP network is 24 per site. One local system can be connected with an IP control unit (IS-IPC).
Up to 31 PC master stations (IS-SOFT) can be connected with an IP network per site. If you do so, at least one IP control unit (IS-IPC), color
monitor IP master station (IS-IPMV) or IP vandal-resistant video door station (IS-IPDV or IS-IPDVF) should be also connected.
Max. number
20160IS-DVF
-
-
IS-PU-UL
or
IS-PU-S
IS-PU-UL
or
IS-PU-S
32
*4
*4
7
Cables
Cables and connectors are not included with the products.
Refer to page 9 to 26 for details about each unit connection.
Notes on cables
Unless otherwise noted, never use individual
•
conductors, twisted pair cable or coaxial cable.
Notes on CAT5e/6 cables
Do not bend the cables to an extent where the radius is
•
less than 25 mm (1”). Communication failure could result.
Odd number cables, such as
•
three conductor wire, cannot be
used.
Arrange the color code of the RJ45 connections in accordance
•
with EIA/TIA-568A or 568B.
Pair2
CAT5e/6 cable
25mm (1") or more
CAT5e/6 cable
Less than 25mm (1")
Do not remove the CAT5e/6 cable jacket more than
•
necessary.
Be sure to check the condition of cable connections with a
•
LAN checker before connecting with a LAN cable.
An RJ45 connector with a cover cannot be connected to the
•
port for CAT5e/6 on master stations, door stations, or room sub
stations. Use a cable without a cover for the units except for the
control units.
Do not pull or put excess strain on CAT5e/6 cables.
•
Use a straight-through cable for connecting units. Use a
•
crossover cable when connecting with a PC directly.
Pair1
Pair3
1234567812345678
T568A
How to connect or disconnect stranded wires.
Twist the strands together, then insert the • wire into one of the quick coupling terminals.
To ensure that the wire won't bend, press the release button while inserting into terminal.
•
Pair4
Pair2
Pair3
Pair1
T568B
Pair4
Release button
8
8mm
(3/8")
e.g.) IS-MV (back)
e.g.) IS-CCU
Release button
*
Strip off the cable jacket by following the indication
on each unit.
e.g.) IS-CCU
UNIT DETAILS
Control unit common information
*
The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (ISRCU) and IP control unit (IS-IPC).
Accessories
■
*1
Mounting bracket × 2
・
Screw (for wall-mounting) × 4
・
Screw (for rack-mounting) × 4
・
Screw (for fi xing mounting bracket) × 6
・
Mounting
■
<When mounting into the 19-inch rack>
Attach the mounting brackets
1
to the unit.
Screw hole x 3
Installation manual (a booklet)
・
CD-ROM (Installation manual, Setting manual and Operation manual)
・
China RoHS paper × 1
・
× 1
*2
× 1
*1: IS-CCU only
*2: IS-CCU and IS-IPC only
19-inch rack (2U)
Mounting bracket x 2 (included)
Screw (for fi xing mounting bracket) x 6 (included)
NOTE:
Do not use screws other than the included ones.
<When mounting on a wall>
Attach the mounting brackets to
1
the unit.
NOTE:
Do not use screws other than the included ones.
Screw (for fi xing mounting
bracket) x 6 (included)
Screw (for wall-mounting)
x 4 (included)
Mount the unit on the wall with
2
the screws for wall-mounting.
Screw (for rack-mounting) x 4 (included)
Set the unit in the
2
44.5 mm
(1-3/4")
NOTE:
If the control unit is installed in a closed rack or
multiunit rack assembly, the temperature around the unit
may become high when operating. Install the control
unit in an environment whose temperature will not rise
beyond the maximum permissible ambient temperature
of the control unit.
65 mm (2-9/16")
NOTE:
When mounting on a wall, mount the terminal side
down.
19-inch rack and fi x
it with screws.
450 mm (17-3/4")
65 mm (2-9/16")
9
Central control unit (IS-CCU
Part names
■
CONTACT INPUT terminals
CONTACT OUTPUT terminals
PA (Paging) OUTPUT terminals
)
CHIME INPUT terminals
External chime source volume 1 and 2
Adjust the volume of the input source (for chime) connected to the
CHIME INPUT B1 and B2 terminals respectively.
Room sub control unit
(IS-RCU) ports
MASTER STATION ports
VIDEO/AUDIO DOOR/SUB
STATION ports
Add-on control unit (IS-SCU) ports
IP control unit (IS-IPC) ports
NOTE:
The illustration of the unit may differ from the actual one.
VIDEO OUTPUT port 1
and port 2
POWER switch
Turns the power ON (
POWER LED (green)
Lights up when the power is ON.
POWER terminals
STATUS LED (green)
Blinks when this unit is initialized or an error
occurs.
The LED will light up when this unit returns to
the normal state.
1
*
: Communication error in a unit connected
to this unit, or between this unit and a unit
connected to it, etc.
Link/ACT LED (green)
Operates when this unit is connected to LAN.
LAN port
Connect a PC to this port for making the system settings.
(Refer to the SETTING MANUAL for details about the
settings.)
) or OFF ( ).
1
*
Specifi cations
■
Central control unit (IS-CCU)
Power source48V DC (supplied from the power supply unit)
Current consumptionMax. 800mA
Ambient temperature0 - 40°C (+32°F - +104°F)
Talk channels・Video
channels
Master station(s)Max. 4
Video door station(s)
Audio door station(s)
Room sub station(s)
Add-on control unitMax. 2
Room sub control unitMax. 4
IP control unitMax. 1
Contact output
(Electric door strike, strobe light, etc.)
*8
*1
NP
2C
φ0.65-1.2mm
(22-16 AWG)
AC
transformer
PT
NP
2C
φ0.65-1.2mm
(22-16 AWG)
Contact input
Sensor, etc.
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
P
Chime input (50mVrms, 600Ω)
External sound
*9
source such as
CD player, etc.
*2
*3
NP
2C
φ0.65-1.2mm
(22-16 AWG)
P
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
*6
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
Monitor 1,
Recorder 1
BNC
connector
Coax
15m (50')
NTSC
BNC
connector
*7*7
Monitor 2,
Recorder 2
BNC
connector
Coax
15m (50')
NTSC
BNC
connector
PC for setting
the system
*4
CAT5e/6
(non-shielded)
200m
(650')
CX1/IP1CX2/IP2
P1 P2 P3 P4L1 L2L3 L4L5 L6L7 L8
CONTACT OUTPUT (AC/DC24V 0.5A)
MASTER STATIONIS-SCUIS-IPC
M1
M3
M2
M4
CAT5e/6
(non-shielded)
M
1CX1
1CX2
CAT5e/6
(non-shielded)
200m
(650')
PA OUTPUT (600Ω)
IS-RCU
2CX1
3CX1
2CX2
3CX2
4CX1
4CX2
CAT5e/6
(non-shielded)
300m
(980')
150m
(490')
C
DOOR/SUB STATION
CAT5e/6
(non-shielded)
300m
(980')
or
VIDEO/AUDIO
D1
D2
D
D3
D4
S1 E S2 E S3 E S4 E
CONTACT INPUT
1MX1
1MX2
CHIME INPUT
1MX3
2MX2
2MX1
2MX3
CAT5e/6 (x3)
(non-shielded)
200m
(650')
B2B1
(600Ω)
IP1 IP2 IP3MX1 MX2 MX3
V1V2
VIDEO OUTPUT
IP1
IP2IP3
φ0.8-1.2mm
(20-16 AWG)
CAT5e/6 (x3)
(non-shielded)
10m (33')
LAN
ETHERNET
2C
DC48V
P
15m
(50')
*5
Room sub control unit
(IS-RCU)
Master station
(IS-MV)
Room sub station
(IS-RS)
Door station
(IS-DV/IS-DVF/
IS-SS)
Add-on control unit
(IS-SCU)
IP control unit
(IS-IPC)
Power supply unit
(IS-PU-UL/IS-PU-S)
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: This connection is needed when a sound source etc. that needs a trigger input is connected. (Up to AC/DC 24V 0.5A) Connect a timer to the
CONTACT INPUT terminals when an external sound source device (CD player etc.) that does not have a timer function is connected.
*3: This connection is needed when a sound source that has a trigger output is connected.
*4: Refer to the SETTING MANUAL for connection and settings.
*5: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*6: Do not use an external sound source as background music. If the background music is interrupted by another performance during chime paging,
the chime paging will not be restored after the performance ends.
*7: Outputs images only from a video door station connected to this unit.
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with
the unit and terminal names to which they are to be connected.
•
For connecting other manufacturer’s products, refer to the
instruction manuals for those products.
•
The illustration of the unit’s front panel differs from the actual
*9: Input specifi cations
Input methodN/O or N/C dry closure contact (start
signal only detection method)
Detection confi rmation
100 ms or more
time
Contact resistanceDuring N/O dry closure: Less than 700 Ω
During N/C dry closure: At least 4 k Ω
Terminal short currentLess than 10 mA
Voltage between
terminals
Less than 5 V DC (when open between
terminals)
one. This is for simplifying the connection diagram.
11
Add-on control unit (IS-SCU
Part names
■
CONTACT OUTPUT terminals
PA (Paging) OUTPUT terminals
)
MASTER STATION ports
VIDEO/AUDIO DOOR/SUB STATION ports
Central control unit (IS-CCU) ports
* No connection allowed.
NOTE:
The illustration of the unit may differ from the actual one.
ID setting switch
(→P.13)
VIDEO OUTPUT port 1 and port 2
POWER switch
Turns the power ON (
POWER LED (green)
Lights up when the power is ON.
POWER terminals
STATUS LED (green)
Blinks when this unit is initialized or an error
occurs.
The LED will light up when this unit returns to
the normal state.
1
*
: Communication error in a unit connected
to this unit, or between this unit and a unit
connected to it, etc.
) or OFF ( ).
1
*
Specifi cations
■
Add-on control unit (IS-SCU)
Power source48V DC (supplied from the power supply unit)
Current consumptionMax. 1.2A
Ambient temperature0 - 40°C (+32°F - +104°F)
Talk channels・Video
channels
Master station(s)Max. 8
Video door station(s)
Room sub station(s)
Video output
MountingRack-mount (19-inch, 2U rack) or wall mount
MaterialSteel plate
ColorBlack
Local system: 2 talk & 2 video channels,
1 chime
Max. 8Audio door station(s)
NTSC
BNC (Video channel 1,2)
12
■ Connections
PA output
(50mVrms, 600Ω)
PA amplifi er
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
*1
NP
2C
φ0.65-1.2mm
(22-16 AWG)
Contact output *4
(Electric door strike, strobe light, etc.)
NP
2C
φ0.65-1.2mm
AC
transformer
(22-16 AWG)
PT
Monitor 1,
Recorder 1
BNC
connector
Coax
15m (50')
NTSC
Monitor 2,
Recorder 2
BNC
connector
Coax
15m (50')
NTSC
P1 P2 P3 P4L1 L2L3 L4
PA OUTPUT (600Ω)
MASTER STATION
M1M2M3M4M5M6M7
M8
CAT5e/6
(non-shielded)
300m
(980')
M
CAT5e/6
(non-shielded)
300m
(980')
CONTACT OUTPUT (AC/DC24V 0.5A)
VIDEO/AUDIO DOOR/SUB STATION
D1
D3D4D5D6D7
D2
CAT5e/6
(non-shielded)
150m
(490')
D
or
BNC
connector
VIDEO OUTPUT
IS-CCU
MX1 MX3
D8
C
MX2
1MX1 1MX2 1MX3
CAT5e/6 (x3)
(non-shielded)
200m
(650')
V1V2
1
2
ID setting switch
BNC
connector
ID
NP: Non-polarized
P: Polarized
DC48V
*3
P
2C
φ0.8-1.2mm
(20-16 AWG)
15m(50')
*2
Master station
(IS-MV)
Door station
(IS-DV/IS-DVF/
IS-SS)
Room sub station
(IS-RS)
Central control unit
(IS-CCU)
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*3: Setting the ID setting switch
ID No.Switch positionDescription
ID 1
ID 2
ON
OFF
ON
OFF
Set to this position when this unit is connected to 1MX1, 1MX2 and 1MX3 ports of IS-CCU.
Set to this position when this unit is connected to 2MX1, 2MX2 and 2MX3 ports of IS-CCU.
*4: Refer to “Output specifi cations” (→P.11).
NOTES:
•
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacturer’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s front panel differs from the actual one. This is for simplifying the connection diagram.
Power supply unit
(IS-PU-UL/IS-PU-S)
13
Room sub control unit (IS-RCU
Part names
■
CONTACT OUTPUT terminals
PA (Paging) OUTPUT terminals
)
AUDIO DOOR/SUB STATION ports
Central control unit (IS-CCU) /
IP control unit (IS-IPC) ports
NOTE:
The illustration of the unit may differ from the actual one.
Specifi cations
■
Room sub control unit (IS-RCU)
Power source48V DC (supplied from the power supply unit)
Current consumptionMax. 1.8A
Ambient temperature0 - 40°C (+32°F - +104°F)
Talk channelsLocal system: 2 talk channels, 1 chime
Audio door station(s)
Room sub station(s)
MountingRack-mount (19-inch, 2U rack) or wall-mount
MaterialSteel plate
ColorBlack
Max. 30
ID setting switch
(→P.15)
POWER switch
Turns the power ON (
POWER LED (green)
Lights up when the power is ON.
POWER terminals
STATUS LED (green)
Blinks when this unit is initialized or an error
occurs.
The LED will light up when this unit returns to
the normal state.
1
*
: Communication error in a unit connected
to this unit, or between this unit and a unit
connected to it, etc.
) or OFF ( ).
1
*
14
Connections
■
(50mVrms, 600Ω)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
PA output
PA amplifi er
Contact output
(Electric door strike, strobe light, etc.)
*4
*1
NP
2C
φ0.65-1.2mm
(22-16 AWG)
P1 P2 P3 P4L1 L2L3 L4
PA OUTPUT (600Ω)
C1
C3C4C5C6C7C8C9
C2
AC
transformer
C11
C10
C12
NP
2C
φ0.65-1.2mm
PT
(22-16 AWG)
CONTACT OUTPUT (AC/DC24V 0.5A)
AUDIO DOOR/SUB STATION
C13
C15
C14
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
IS-CCU/
IS-IPC
CX1/IP1
CX2/IP2
NP: Non-polarized
P: Polarized
ID setting switch
1
2
3
ID
4
*3
DC48V
CAT5e/6
(non-shielded)
150m
(490')
C
Room sub station
(IS-RS)
(non-shielded)
or
Audio door station
(IS-SS)
CAT5e/6
300m
(980')
D
CAT5e/6 (x2)
(non-shielded)
10m
(33')
IP control unit
(IS-IPC)
IP1IP2
or
1CX1 1CX2
Central control unit
(IS-CCU)
CAT5e/6 (x2)
(non-shielded)
200m
(650')
*1: This connection is needed when a PA amplifi er that needs a trigger input is connected. (Up to AC/DC 24V 0.5A)
*2: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
*3: Setting the ID setting switch
ID No.Switch positionDescription
ID 1
ID 2
ID 3
ID 4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Set to this position when this unit is connected to 1CX1 and 1CX2 ports of IS-CCU.
Set to this position when this unit is connected to IS-IPC.
Set to this position when this unit is connected to 2CX1 and 2CX2 ports of IS-CCU.
Set to this position when this unit is connected to 3CX1 and 3CX2 ports of IS-CCU.
Set to this position when this unit is connected to 4CX1 and 4CX2 ports of IS-CCU.
*4: Refer to “Output specifi cations” (→P.11).
P
2C
φ0.8-1.2mm
(20-16 AWG)
15m (50')
*2
Power supply unit
(IS-PU-UL/IS-PU-S)
NOTES:
•
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacturer’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s front panel differs from the actual one. This is for simplifying the connection diagram.
15
IP control unit (IS-IPC
IP
This unit is needed to connect a local system to a standard (IP) system.
:
Part names
■
)
CO port (Telephone)
Central control unit (IS-CCU) /
Room sub control unit (IS-RCU) ports
LAN port
POWER switch
Turns the power ON ( ) or OFF ( ).
POWER LED (green)
Lights up when the power is ON.
POWER terminals
STATUS LED (green)
Blinks when this unit is initialized or an error
occurs.
The LED will light up when this unit returns to
the normal state.
1
*
: Communication error in a unit connected
to this unit, or between this unit and a unit
connected to it, etc.
Link/ACT LED (green)
Operates when this unit is connected to LAN.
1
*
NOTE:
The illustration of the unit may differ from the actual one.
Specifi cations
■
IP control unit (IS-IPC)
Power source48V DC (supplied from the power supply unit)
Current consumptionMax. 105mA
Ambient temperature0 - 40°C (+32°F - +104°F)
Talk channels・Video
channels, other channels
Central control unit
Room sub control unit
LANEthernet (10 BASE-T, 100 BASE-TX)
MountingRack-mount (19-inch, 2U rack) or wall-mount
MaterialSteel plate
ColorBlack
2 talk & 2 constrained video channels,
1 chime, and 1 telephone (North America
only)
Max. 1
16
Connections
■
P: Polarized
PBX/Telephone
(North America only)
CAT5e/6 (x2)
(non-shielded)
10m (33')
CX1/IP1 CX2/IP2
CO
TELEPHONE
IS-CCU
IS-RCU
IP1IP2IP3
IP1IP2IP3
or
IP1IP2IP3
IS-CCU
IS-RCU
CAT5e/6 (x3)
(non-shielded)
10m (33')
Switch (Hub)
10BASE-T
100BASE-TX
100m (330')
ETHERNET
LAN
DC48V
P
2C
φ0.8-1.2mm
(20-16 AWG)
15m (50')
Room sub control unit
(IS-RCU) *2
Central control unit
(IS-CCU) *1
Power supply unit
(IS-PU-UL/IS-PU-S)
*1: When connecting a central control unit (IS-CCU) to this unit, connect it to the IP1, IP2 and IP3 ports.
*2: When connecting a room sub control unit (IS-RCU) to this unit, connect it to the IP1 and IP2 ports.
*3: Do not install two power supplies in parallel to a single input. Be sure to connect a single power supply unit to a control unit.
NOTES:
•
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacturer’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s front panel differs from the actual one. This is for simplifying the connection diagram.
*3
17
Color monitor master station (IS-MV)
*
For the part names and their functions, see the OPERATION MANUAL.
Accessories
■
Mounting bracket × 1
・
Desktop stand × 1
・
Tie-wrap × 1
・
Name plate × 1
・
Mounting
■
When mounting on a wall
<Back wiring>
Name card × 1
・
Screw (15mm (5/8"), for wall-mounting) × 4
・
Screw (25mm (1"), for gang box) × 4
・
Screw (10mm (7/16"), for desktop stand) × 4
・
China RoHS paper × 1
・
Name card × 1 (included*1)
Name plate × 1 (included*
Filling in the target names on
the name card
Remove the transparent name plate by
1
pushing either upper or lower side of the
plate.
Remove the name card if necessary.
*
Fill in the target names on the white
2
space of the name card.
Replace the name plate.
3
1
The name plate and name card are
:
*
attached to the unit with shipment.
<Surface wiring>
1
)
The unit
Mount the unit on the
3
mounting bracket.
CAT5e/6 cable
Connect the CAT5e/6 cable
2
and option wires to the unit.
3-gang box
NOTE:
A single-gang box can also be
used for wiring. When using
a single-gang box, fasten the
mounting bracket to the wall
directly by using the screw holes
for 3-gang box.
Mounting bracket
(attached to the unit with shipment)
Fasten the mounting
Screw (for gang box) × 4 (included)
Option wires
1
bracket to the wall.
Connect the CAT5e/6 cable and option wires
to the unit and route them as shown.
18
92mm (3-5/8")
83.5mm (3-5/16")
Mounting bracket
(attached to the unit with shipment)
Screw (for wall-mounting) × 4 (included)
The unit
When mounting on a desktop stand
Mount the unit on the
4
mounting bracket.
2
CAT5e/6 cable
Fasten the mounting
bracket to the desktop
stand.
Set up the desktop
1
stand.
Set up the desktop stand on *
a level surface etc. so that it
is stabilized. Fix the desktop
stand in place if needed.
The desktop stand allows you *
to adjust it in 3 setup angles.
Put the leg in a groove on the
base that corresponds to the
desired angle.
30r
The unit
Option wires
Screw (for desktop stand) × 4
(included)
Connect the CAT5e/6 cable
3
and option wires to the unit.
Mounting bracket
(attached to the unit
with shipment)
NOTES:
•
Attach the screws to the screw holes for 3-gang box on the mounting
bracket to make both sides of the mounting bracket contact the desktop
stand.
•
If necessary, secure the CAT5e/6 cable with the tie-wrap (included).
Connections
■
Audio output
(50mVrms, 600Ω)
Recorder, etc.
2C
NP
15m (50')
Video output
Monitor, etc.
Coax
P
10m (33')
NTSC
Desktop stand
(included)
Base
Leg
45r
60r
CAT5e/6
M
(non-shielded)
300m (980')
(Select one port.)
M1
M4
Central control unit
(IS-CCU)
or
V
VIDEO
OUTPUT
V
AUDIO
A
OUTPUT
A
NP: Non-polarized
P: Polarized
NOTES:
•
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacture’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
CAT5e/6
(non-shielded)
300m (980')
M8
M1
(Select one port.)
Add-on control unit
(IS-SCU)
19
Vandal-resistant video door station (IS-DV, IS-DVF),
Vandal-resistant audio door station (IS-SS)
Accessories
■
Screw (for wall-mounting) × 4 (IS-DV only)
・
Anchor × 4 (IS-DV only)
・
Transparent name plate × 2 (IS-DV and IS-DVF only)・China RoHS paper × 1
・
Special screw × 4 (IS-DVF and IS-SS only)
・
Mounting locations (IS-DV and IS-DVF)
■
Do not install this unit in any of the following locations where lighting or the ambient environment could impact the display on the
video monitor due to the characteristics of the door station's camera.
Special screwdriver × 1
・
Back box × 1 (IS-DVF and IS-SS only)
・
Locations subject to
a
direct sunlight
Mounting positions and image view area of video door station (IS-DV and IS-DVF)
■
Wide picture
Approx.
1,050 mm
(3' 5")
Zoom picture
Approx. 900 mm (3')
The zoom position can be changed.
(Refer to the OPERATION MANUAL.)
The factory setting is "Center" for Zoom mode.
Objects appear
smaller due to
greater distortion
in the surrounding
sections compared to
the central section,
but a wider area is
displayed.
The display range is
a rough estimation
and may change due
to the installation
environment.
Approx. 700 mm (2' 3")
There is a white wall behind
b
the caller
Wide picture
Up/Down
Approx. 2,050 mm (6' 9")
Approx. 1,050 mm (3' 5")
Approx. 1,000 mm (3' 4")
Left/Right
Mounting position
1,500 mm (5')
Approx. 170°
500 mm (20")
500 mm (20")
Other locations subject to strong
c
lighting or backlighting conditions
Approx. 1,850 mm (6' 1")
Unit center
1,500 mm (5')
Approx. 1,050 mm (3' 5")
Approx. 800 mm (2' 7")
An area over a range of approx. 170° in a 500 mm
(20") radius from the camera displays.
(The display range is a rough estimation and may
change due to the installation environment.)
Mounting position
1,300 mm (4' 3")
Unit center
1,300 mm (4' 3")
500 mm (20")
Zoom picture (when mounting position is 1,500 mm (5'))
Up/Down
Approx. 2,300 mm (7' 7")
Approx. 850 mm (2' 9")
Approx. 1,450 mm (4' 9")
Left/Right
Approx. 100 mm
Zoom <Up>
500 mm
1,500 mm (5')
(20")
Zoom <Left>
500 mm (20")
(4")
Approx. 1,300 mm (4' 3")
Unit center
20
Zoom <Center>
Approx. 1,900 mm (6' 3")
Approx. 700 mm (2' 3")
Approx. 1,200 mm (3' 11")
Zoom <Center>
Approx. 900 mm (3')
500 mm (20")
Unit center
1,500 mm (5')
500 mm (20")
Zoom <Down>
Approx. 1,600 mm (5' 4")
Approx. 850 mm (2' 9")
Approx. 750 mm (2' 5")
Zoom <Right>
500 mm (20")
Approx. 1,300 mm (4' 3")
500 mm (20")
Unit center
1,500 mm (5')
Approx. 100 mm (4")
Mounting
■
IS-DV (surface-mount)
Loosen the screw
1
with the special
screwdriver, and
remove the front
panel.
Loosen
Special
screwdriver
(included)
Fasten the unit to the
4
mounting surface.
*
Use board anchors or concrete
plugs as needed.
Vandal-resistant
front panel
Anchor x 4
(included)
Option wires
The unit
Screw (for wall-mounting) × 4
(included)
Water escape holes
Do not block the holes.
CAT5e/6 cable
NOTE
Make room for threading a screw.
Screw mounting
hole x 4
Ø 6 mm
(Ø 1/4")
Mounting height
GL=1,500 mm (5')
3
35 mm
(1-3/8")
Unit
center
25 mm (1")
Open the terminal cover, and
Unit center
90 mm (3-9/16")
81 mm (3-1/4'')
connect the CAT5e/6 cable and
option wires to the unit.
194 mm (7-11/16'')
25 mm (1")
Tighten
Attach the front panel to the unit by
5
hanging the upper 2 parts on the unit.
*
Tighten the screw with the lower part of
the front panel pressed to the wall.
IS-DVF (fl ush-mount), IS-SS (fl ush-mount)
e.g.) IS-DVF
Flush mount back box (included)
Vandal-resistant front panel with the unit attached
Insert the transparent name plate.
2
(IS-DV and IS-DVF)
Peel off the protective seals on the plate (both sides).
1
Fill in the name on the transparent name plate.
2
Be sure to leave 25 mm (1") of white space on the
right end to account for insertion.
Insert the fi lled-in transparent name plate at the
3
specifi ed insertion opening (indicated with
diagram).
To insertion opening
120 mm
(4-3/4'')
235 mm
(9-5/16'')
in
ABCDEFG
2 mm (1/8")
Install the back box in the wall, and
1
then connect the CAT5e/6 cable
and option wires to the unit with the
terminal cover open.
To
insertion
opening
25 mm
(1")
Special screwdriver
(included)
Fasten the front panel to the
3
back box with the special screws.
Loosen
Tighten
Special screw x 4
(included)
Mounting height (box center)
GL=1,500 mm (5')
45 mm
(1-13/16'')
Transparent name plate
Insert the transparent name plate. (IS-DVF only)
2
*
See above for details.
21
Connections (IS-DV and IS-DVF)
■
Electric door strike
*
Connect to the electric door strike
*1
φ0.65-1.2mm
(22-16 AWG)
10m (33')
φ0.65-1.2mm
(22-16 AWG)
10m (33')
AC transformer
φ0.65-1.2mm
(22-16 AWG)
10m (33')
according to its specifi cations.
CAT5e/6
D
(non-shielded)
300m (980')
D4
D1
(Select one port.)
Central control unit
(IS-CCU)
or
NC
NO
COM
PT
Option
wires
CAT5e/6 cable
CAT5e/6
(non-shielded)
300m (980')
Inlet
Terminal cover
D1
D8
(Select one port.)
*
The terminals are inside the terminal
Add-on control unit
(IS-SCU)
cover. After connecting, route the
wires through the wiring paths, then
close the cover.
*
Be sure to route the CAT5e/6 cable
and option wires through inlet.
*
When closing the terminal cover,
close it until it clicks.
Do not use the unoccupied terminals and ports for other purposes.
•
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•
For connecting other manufacture’s products, refer to the instruction manuals for those products.
•
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
23
Room sub station (IS-RS)
Accessories
■
Mounting bracket × 1
・
Screw (for wall-mounting) × 2
・
Tie-wrap × 1
・
Mounting
■
<Back wiring>
Screw (for gang box) × 2
・
China RoHS paper × 1
・
Mount the unit
3
on the mounting
bracket.
The unit
Option wires
Connect the CAT5e/6 cable
2
CAT5e/6 cable
Mounting bracket (attached to the unit with shipment)
Screw (for gang box) × 2 (included)
1-gang box
Fasten the mounting
1
bracket to the wall.
and option wires to the unit.
<Surface wiring>
When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on the upper part of
the unit to allow passage of the wiring into the unit.
Cable inlet
24
The unit
83.5 mm
(3-5/16'')
Mounting bracket
(attached to the unit with shipment)
Screw (for wall-mounting) × 2 (included)
Connections
■
Contact output
(Electric door strike,
strobe light, etc.)
The power supply unit cannot be mounted on a wall directly.
•
By using the IS-RACK (sold separately), the power supply unit can be set in the 19-inch rack or mounted on a wall.
•
Up to 3 power supply units can be *
mounted on the rack.
AC cord requirements
■
Type: Must comply with requirements set out by the Safety Approval/Certifi cation Organization in each country of use.
•
Employ a plug in style and ratings matched with AC outlet to be used.
•
Model
name
IS-PU-UL
Plug confi gurationUsage
North American125V, 10A
DC output terminals
AC cord
(approx.1.8m (6'))
AC cord inlet
Plug in the AC cord securely.
2
Rack for the power supply unit (IS-RACK)
The IS-RACK is available. Consult an authorized *
Aiphone dealer for details.
Nominal voltage &
current rating
26
IS-PU-S
Universal European250V, 6A
TECHNICAL DATA AND PRECAUTIONS
Technical data
Operating temperature:
•
Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC),
Master station (IS-MV), Room sub station (IS-RS),
Power supply unit (IS-PU-UL, IS-PU-S)
Door station (IS-DV, IS-DVF, IS-SS)-10 - 60°C (+14°F - +140°F)
Dimensions:
•
Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC)425 (W) x 88 (H) x 280 (D) mm
Color monitor master station (IS-MV)250 (W) x 189 (H) x 59 (D) mm
Vandal-resistant video door station (IS-DV)105 (W) x 215 (H) x 32 (D) mm
Vandal-resistant video door
station (IS-DVF)
Vandal-resistant audio door
station (IS-SS)
Room sub station (IS-RS)116.5 (W) x 199 (H) x 64 (D) mm
Power supply unit (IS-PU-UL, IS-PU-S)130 (W) x 265 (H) x 83 (D) mm
IS-DVF150 (W) x 265 (H) x 38 (D) mm
Flush mount back box120 (W) x 235 (H) x 45 (D) mm
IS-SS150 (W) x 265 (H) x 32 (D) mm
Flush mount back box120 (W) x 235 (H) x 45 (D) mm
0 - 40°C (+32°F - +104°F)
16-3/4" (W) x 3-1/2" (H) x 11-1/16" (D)
9-7/8" (W) x 7-1/2" (H) x 2-3/8" (D)
4-3/16" (W) x 8-1/2" (H) x 1-5/16" (D)
5-15/16" (W) x 10-7/16" (H) x 1-1/2" (D)
4-3/4" (W) x 9-5/16" (H) x 1-13/16" (D)
5-15/16" (W) x 10-7/16" (H) x 1-5/16" (D)
4-3/4" (W) x 9-5/16" (H) x 1-13/16" (D)
4-5/8" (W) x 7-7/8" (H) x 2-9/16" (D)
5-1/8" (W) x 10-7/16" (H) x 3-5/16" (D)
Weight:
•
Control unit (IS-CCU, IS-SCU, IS-RCU)Approx. 4.0 kg (8.82 lbs.)
IP control unit (IS-IPC)Approx. 3.6 kg (7.94 lbs.)
Color monitor master station (IS-MV)Approx. 820 g (1.81 lbs.)
Vandal-resistant video door station (IS-DV)Approx. 520 g (1.15 lbs.)
Vandal-resistant video door
station (IS-DVF)
Vandal-resistant audio door
station (IS-SS)
Room sub station (IS-RS)Approx. 530 g (1.17 lbs.)
Power supply unit (IS-PU-UL, IS-PU-S)Approx. 1.5 kg (3.31 lbs.)
IS-DVFApprox. 810 g (1.79 lbs.)
Flush mount back boxApprox. 600 g (1.32 lbs.)
IS-SSApprox. 820 g (1.81 lbs.)
Flush mount back boxApprox. 600 g (1.32 lbs.)
Technical precautions
Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use an abrasive cleanser or cloth.
•
27
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the fi nal decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty
shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs
must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving
on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its
products during use, or for any consequent inconvenience or losses that may result.
The object area of
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
•
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Increase the separation
•
between the equipment and receiver.
Consult the dealer or an experienced radio/TV technician for help.
•
is the EU.
http://www.aiphone.net/
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE S.A.S., LISSES-EVRY, FRANCE
Printed in Japan