Aiphone IS-DVF Installation Manual

IS SERIES
Commercial & Security Video Intercom system
834168 C P0811JZ
INSTALLATION MANUAL
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference.
Also read the SETTING MANUAL and OPERATION MANUAL on the bundled CD-ROM.
When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non- functional.
IMPORTANT
Do not install the system until you have completely understood the system and this manual.
Please note that the illustrations in this manual may differ from the actual ones.
CONTENTS
PRECAUTIONS ................................ 3
WARNING .......................................3
CAUTION ........................................3
GENERAL PRECAUTIONS ............3
Notes on using this system ..........4
Notices ............................................ 4
SYSTEM CONFIGURATIONS .......... 4
Entire system ................................4
System confi guration examples
Standard (IP) system ............................ 5
CONNECTIONS .............................. 6
System connection diagram .........6
Cables ............................................. 8
UNIT DETAILS ................................ 9
Control unit common information
Accessories .......................................... 9
Mounting ............................................... 9
Central control unit (IS-CCU
Part names ......................................... 10
Specifi cations ..................................... 10
Connections ........................................11
Add-on control unit (IS-SCU
Part names ......................................... 12
Specifi cations ..................................... 12
Connections ....................................... 13
Room sub control unit (IS-RCU
Part names ......................................... 14
Specifi cations ..................................... 14
Connections ...................................... 15
IP control unit (IS-IPC
Part names ......................................... 16
) ................. 16
.... 5
....9
) ...... 10
) ...... 12
.... 14
)
Specifi cations ..................................... 16
Connections ....................................... 17
Color monitor master station
(IS-MV) ..........................................18
Accessories ........................................ 18
Mounting ............................................. 18
Connections ....................................... 19
Vandal-resistant video door station (IS-DV, IS-DVF), Vandal-resistant audio door
station (IS-SS) ..............................20
Accessories ........................................ 20
Mounting locations (IS-DV and IS-DVF)
Mounting positions and image view
area of video door station
(IS-DV and IS-DVF) ........................... 20
Mounting ............................................. 21
Connections (IS-DV and IS-DVF) ....... 22
Connections (IS-SS) ........................... 23
...
20
Room sub station (IS-RS) ...........24
Accessories ........................................ 24
Mounting ............................................. 24
Connections ....................................... 25
Power supply unit
(IS-PU-UL and IS-PU-S) ...............26
Accessories ........................................ 26
Mounting ............................................. 26
AC cord requirements ......................... 26
TECHNICAL DATA AND
PRECAUTIONS .............................. 27
WARRANTY .................... Back cover
After unpacking, check the included parts for each product referring to the corresponding pages.
ABOUT THIS MANUAL
The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your system.
Manual confi gurations
The following manuals are provided for a local system. Read all the manuals for installing, setting up, and using a local system, or provide the manuals to the persons working with the system. * The INSTALLATION MANUAL includes the contents for a standard (IP) system.
INSTALLATION MANUAL (This manual)
Used for installing and connecting control units, stations and power supply unit. (For an installer or serviceman)
SETTING MANUAL (An electronic manual on the CD-ROM included with the central control unit)
Used for making the system settings and system maintenance. (For an installer or serviceman)
OPERATION MANUAL (An electronic manual on the CD-ROM included with the central control unit)
This manual describes how to use this system for calling, communicating, paging, monitoring, etc. (For users of the system)
2
PRECAUTIONS
General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water
General Precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could result.
2. Keep the unit away from water or any other liquid. Fire or electric shock could result.
3. High voltage is present internally. Do not open the case. Electric shock could result.
4. The unit is not of explosion-proof. Do not install or use near gases or fl ammable materials. Fire or explosion could result.
5. Do not connect any non-specifi ed power source to the +, - terminals. Also, do not install two power supplies in parallel to a single input. Fire or damage to the unit could result. Be sure to connect a single power supply unit to a control unit.
6. Do not connect any terminal on the unit to an AC power line. Fire or electric shock could result.
7. Do not use power supply with a voltage other than specifi ed. Fire or electric shock could result.
8. Keep AC cord from being marred or crushed. If the AC cord is fractured, fi re or electric shock could result.
9.
Do not plug or unplug with wet hands. Electric shock could result.
10. Insert AC plug completely and securely into AC outlet. Otherwise, fi re or electric shock could result.
11.
Do not put any metal or fl ammable material into the unit through the openings. Fire, electric shock, or unit trouble could result.
12. The unit must be installed and wired by a qualifi ed technician.
13.
Existing wiring such as chime wiring, etc. may contain high voltage AC electricity. Damage to the unit or electric shock could result. Wiring and installation should be done by a qualifi ed technician.
CAUTION
Negligence could result in injury to people or damage to property.
1.
Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.
2. When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
3. Before turning on power, make sure wires are correctly connected, not crossed or not shorted. If not, fi re or electric shock could result.
4.
Do not install the unit in locations subject to frequent vibration or impact. It may fall or tip over, resulting in damage to the unit or personal injury.
5. For power supply, use Aiphone power supply model or model specifi ed for use with system. If non-specifi ed product is used, re or malfunction could result.
6. On products with ground terminals, connect to an earth ground. Fire or malfunction could result.
7. For DC powered systems, use Aiphone power supply model specifi ed with system. If non-specifi ed product is used, fi re or malfunction could result.
8. Do not put high pressure on the monitor. If fractured, injury could result.
9. If LCD is punctured, do not allow contact with the liquid crystal inside. Infl ammation could result. If necessary, gargle your mouth and clean your eyes or skin with clear water for at least 15 minutes, and consult your doctor.
10. Do not put anything on the unit or cover the unit with cloth, etc. Fire or unit trouble could result.
11. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
Places under direct sunlight or places near heating * equipment that varies in temperature.
Places subject to dust, oil, chemicals, hydrogen sulfi de (hot * spring).
Places subject to moisture and humidity extremes, such as * bathrooms, cellars, greenhouses, etc.
Places where the temperature is quite low, such as inside a * refrigerated area or in front of an air conditioner.
Places subject to steam or smoke (near heating or cooking * surfaces).
Where noise generating devices such as dimmer switches or * inverter electrical appliances are closeby.
12. Be sure to perform a call test or check the volume with the handset on the hook. If you operate the hook switch with the handset on your ear, a sudden call etc. may arrive causing damage to your ear.
GENERAL PRECAUTIONS
1. Keep the unit more than 1 m (3.3') away from radio or TV.
2. Keep the intercom wires more than 30cm (12'') away from AC 100-240V wiring. AC induced noise and/or unit malfunction could result.
3. Install the unit in an area that will be accessible for future inspections, repairs, and maintenance.
4. As to other manufacturer’s devices (such as sensor, detectors, door releases) used with this system, comply with the Specifi cations and Warranty conditions that the manufacturers or venders present.
5. If the unit is down or does not operate properly, turn off the power switches and unplug the power supply.
6. If it is used close to a cellular phone, the unit may malfunction.
7. The unit can be damaged if dropped. Handle with care.
8. The unit turns inoperative during power failure.
9. In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
10. All the units, except for door station, is designed for indoor use only. Do not use outdoor.
11. This product, being a control unit of door release, should not be used as a crime prevention device.
12. It must be noted in advance that the LCD panel, though manufactured with very high precision techniques, inevitably will have a very small portion of its picture elements always lit or not lit at all. This is not considered a unit malfunction.
13. Door station is weather-resistant, but do not spray with high­pressure water. Unit trouble could result.
14. For wiring, specify CAT5e/6 straight cable.
15. Due to the environmental sound around the unit, it may hinder smooth communication, but this is not a malfunction.
16. When outside temperature lowers sharply after rainfall, etc., the inside of camera may fog up slightly, causing a blurry picture, but this is not a malfunction. Normal operation will be restored when moisture evaporates.
17. Do not locate the units in a location with restricted access. It impedes maintenance inspection or repairs. Also, unit trouble could result.
3
Notes on using this system
The ID/Password to access the web server for setting the system
is the customer's responsibility. Make sure you set a password that cannot be easily guessed by a third party. We recommend that you change the ID/Password on a regular basis.
Notices
We will under no conditions be liable for damage that occurs due
to failures in network equipment; failures due to internet providers and cell phone companies; failures such as disconnected lines and other losses in communication, which render it impossible to provide this service or in any way delay this service due to causes outside of our responsibility; or if an error or missing data occurs during transmission.
We will under no conditions be liable for damage that occurs due
to the inability to communicate due to malfunctions, problems, or operational errors in this product.
We will under no conditions be liable for damage caused if a
customer's password or transmitted information are leaked through bugging or unlawful computer access over Internet communication.
We will under no conditions be liable for any damages or losses
resulting from this product's contents or specifi cations.
This manual was created by Aiphone Co., Ltd., all rights reserved.
Copying a part of or this entire manual without prior permission from Aiphone Co., Ltd. is strictly forbidden.
Please note that images depicted in this manual may differ from the
actual images. Please note that this manual may be revised or changed without
prior notice. Please note that product specifi cations may be changed for the sake
of improvement without prior notice. Please be aware that it is the customer's responsibility to ensure that
their computer is secure. We will under no conditions be liable for security failures.
This system is not intended for life support or crime prevention. It is
just a supplementary means of conveying information. Aiphone will under no conditions be liable for loss of life or property which occurs while the system is being operated.
SYSTEM CONFIGURATIONS
The IS system is a commercial and security video intercom system especially designed for applications in facilities such as offi ce buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system, urgent call system, public announcement system, and access control system.
The IS system can be constructed on an IP network so multiple sites of IS system can be connected and controlled as a global system. You can design the system to any scale depending on your needs.
Entire system
An entire system can have up to 32 sites connected on an IP network. In this system, calling, communication, etc. are possible among sites.
Site 1
Site 2
Site 32
Site 3
Site 4
4
System confi guration examples
Standard (IP) system
The following is an example of standard (IP) system for controlling security and communication for facilities.
A site must be confi gured with an IP-based system.
A standard (IP) system can consist of local systems and IP units.
A local system (Hard wired network system) without connecting to an IP network can also be an independent system.
When using a local system as an independent system, it needs at least one central control unit (IS-CCU). To connect a local system
to a standard (IP) system, one IP control unit (IS-IPC) is needed. An IP unit (PC master station, IP door station or IP master station) can be connected directly to a LAN.
In a site, up to 32 IP units (including up to 8 IP control units) can be connected.
Telephone
Site 1
: Control offi ce, etc.
IP
PSTN / private line (North America only)
Internet / WAN
Standard (IP) system
IS-RCU
IS-RCU
Site 3
Site 2
PBX telephone
LAN (IP network)
IP IP IP
IS-IPC
IS-CCU
IS-RCU
IS-RCU
Building 1 Building 2
IS-SCU IS-SCU
IS-IPC
IS-CCU
IS-RCU
IS-IPC
IS-RCU
Building 3
Site 32
Building 4
IP
IPIP
Local system
This is also a local system, however no communication can be made on this system without connecting with an IP network.
IP
IP unit
5
CONNECTIONS
System connection diagram
The following is an example of standard (IP) system connection diagram.
Refer to page 9 to 26 for details about each unit connection.*
To Internet/WAN
Broadband router
Local system
PA speaker
PA speaker
Timer
CD player
PA amplifi er
PA amplifi er
IP
IS-CCU
(Max. 30)
IS-RS
PBX / Telephone
IS-IPC
IS-RCU
Switch (Hub)
*1
IS-PU-UL
or
IS-PU-S
and /or
(Max. 4)
IS-SS
(Max. 1)
IS-PU-UL
IS-PU-S
IS-PU-UL
or
IS-PU-S
or
IS-MV
(Max. 8)
IS-MV
IS-DV/IS-DVF
/IS-SS
(Max. 4)
IS-SCU
(Max. 4)
and /or
(Max. 2)
IS-PU-UL
or
IS-PU-S
(Max.8)
IS-DV/IS-DVF
/IS-SS
IS-RS
PT
AC transformer
PA amplifi er
IS-RS
and /or
Monitor
Recorder
PA speaker
EL-12S Electric door strike
8Ω speaker
Call button
Strobe light
*1: An IP control unit (IS-IPC) is needed to connect a local system to a standard (IP) system.
6
Monitor
Recorder
AC
PT
transformer
EL-12S Electric door strike
Telephone network
LAN (IP network)
: IS system product
: IP unit
IP
Switch (Hub)
IS-SS
and /or
Strobe light
(Max. 1)
IP
PC master station (IS-SOFT)
Switch (Hub)Switch (Hub) Switch (Hub)
IS-IPMV
IP
PS-2420/D/UL/S*
PoE
Recorder
2
or
IS-IPDV /IS-IPDVF
IP
PS-2420/D/UL/S*
AC
PT
transformer
EL-12S Electric door strike
or
PoE
Local system
2
PA speaker
IP
PA amplifi er
8Ω speaker
PBX / Telephone
IS-IPC*
(Max. 30)
IS-RS
1
IS-RCU
Call button
*2: Do not use PS-2420S in Europe.
Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system"
Category Model name Type
Local system Standard (IP) system
IS-CCU Central control unit 1 8
Control unit
IS-SCU Add-on control unit 2 16 IS-RCU Room sub control unit 4 32
Master station IS-MV Color monitor master station 20 160
Local
Sub station
IS-DV
IS-SS IS-RS
Vandal-resistant video door station Vandal-resistant video door station
*3
*3
Vandal-resistant audio door station (fl ush-mount) Room sub station 120 960
(surface-mount)
(fl ush-mount)
Control unit IS-IPC IP control unit -
Master station
IP
Sub station
3
: You can use vandal-resistant audio door stations (IS-SS) instead of room sub stations (IS-RS) and vice versa.
*
4
: Up to 8 IP control units (IS-IPC) can be connected with an IP network per site. If you do so, the maximum number of other IP units that can be
*
IS-IPMV Color monitor IP master station ­IS-SOFT (PC master station) PC master station ­IS-IPDV IS-IPDVF
IP vandal-resistant video door station (surface-mount) IP vandal-resistant video door station (fl ush-mount)
connected to the IP network is 24 per site. One local system can be connected with an IP control unit (IS-IPC). Up to 31 PC master stations (IS-SOFT) can be connected with an IP network per site. If you do so, at least one IP control unit (IS-IPC), color monitor IP master station (IS-IPMV) or IP vandal-resistant video door station (IS-IPDV or IS-IPDVF) should be also connected.
Max. number
20 160IS-DVF
-
-
IS-PU-UL
or
IS-PU-S
IS-PU-UL
or
IS-PU-S
32
*4
*4
7
Cables
Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection.
Notes on cables
Unless otherwise noted, never use individual
conductors, twisted pair cable or coaxial cable.
Notes on CAT5e/6 cables
Do not bend the cables to an extent where the radius is
less than 25 mm (1”). Communication failure could result.
Odd number cables, such as
three conductor wire, cannot be used.
Arrange the color code of the RJ45 connections in accordance
with EIA/TIA-568A or 568B.
Pair2
CAT5e/6 cable
25mm (1") or more
CAT5e/6 cable
Less than 25mm (1")
Do not remove the CAT5e/6 cable jacket more than
necessary.
Be sure to check the condition of cable connections with a
LAN checker before connecting with a LAN cable.
An RJ45 connector with a cover cannot be connected to the
port for CAT5e/6 on master stations, door stations, or room sub stations. Use a cable without a cover for the units except for the control units.
Do not pull or put excess strain on CAT5e/6 cables.
Use a straight-through cable for connecting units. Use a
crossover cable when connecting with a PC directly.
Pair1
Pair3
12345678 12345678
T568A
How to connect or disconnect stranded wires.
Twist the strands together, then insert the • wire into one of the quick coupling terminals. To ensure that the wire won't bend, press the release button while inserting into terminal.
Pair4
Pair2
Pair3
Pair1
T568B
Pair4
Release button
8
8mm
(3/8")
e.g.) IS-MV (back)
e.g.) IS-CCU
Release button
*
Strip off the cable jacket by following the indication on each unit.
e.g.) IS-CCU
UNIT DETAILS
Control unit common information
*
The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS­RCU) and IP control unit (IS-IPC).
Accessories
*1
Mounting bracket × 2
Screw (for wall-mounting) × 4
Screw (for rack-mounting) × 4
Screw (for fi xing mounting bracket) × 6
Mounting
<When mounting into the 19-inch rack>
Attach the mounting brackets
1
to the unit.
Screw hole x 3
Installation manual (a booklet)
CD-ROM (Installation manual, Setting manual and Operation manual)
China RoHS paper × 1
× 1
*2
× 1
*1: IS-CCU only *2: IS-CCU and IS-IPC only
19-inch rack (2U)
Mounting bracket x 2 (included)
Screw (for fi xing mounting bracket) x 6 (included)
NOTE:
Do not use screws other than the included ones.
<When mounting on a wall>
Attach the mounting brackets to
1
the unit.
NOTE:
Do not use screws other than the included ones.
Screw (for fi xing mounting
bracket) x 6 (included)
Screw (for wall-mounting)
x 4 (included)
Mount the unit on the wall with
2
the screws for wall-mounting.
Screw (for rack-mounting) x 4 (included)
Set the unit in the
2
44.5 mm (1-3/4")
NOTE:
If the control unit is installed in a closed rack or multiunit rack assembly, the temperature around the unit may become high when operating. Install the control unit in an environment whose temperature will not rise beyond the maximum permissible ambient temperature of the control unit.
65 mm (2-9/16")
NOTE:
When mounting on a wall, mount the terminal side down.
19-inch rack and fi x it with screws.
450 mm (17-3/4")
65 mm (2-9/16")
9
Loading...
+ 19 hidden pages