Thank you for selecting Aiphone for your communication needs. Please read this manual carefully before installation, and keep this in a safe place for future reference.
Please note that images and illustrations depicted in this manual may differ from the actual product.
PRECAUTIONS
Prohibited
Do not dismantle unit
WARNING
(Negligence could result in death or serious injury.)
1. Do not dismantle or alter the unit. Fire or electric shock could result.
2. Do not put any metal and fl ammable material into the unit through the openings. Fire, electric shock, or unit trouble could result.
3. Keep the unit away from water or any other liquid. Fire or electric shock could result.
4. During an electrical storm, do not touch the unit. Electric shock could result.
5. If there is any smoke, unusual odor, or abnormal sound, or if you drop or damage the unit, turn off the system power breaker immediately. Fire or electric shock could result.
6. Do not use power supply with a voltage other than specifi ed. Fire or electric shock could result
7. Do not use the unit in/under following locations/conditions. If not observed, it may result in noises or malfunctions.
• Where use of the unit is prohibited, such as in a hospital
• Near an electric medical equipment (e.g. operating rooms, ICU, or
CCU)
• Near automatic control equipment such as auto doors or fi re-alarm
boxes
• In the area within 15cm from a cardiac pacemaker
CAUTION
(Negligence could result in injury to people or damage to property.)
1. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could result.
2. Do not apply high pressure on the screen. If fractured, injury could result.
3. If the LCD is punctured, do not touch the liquid crystal inside. Infl ammation could result. If contact should occur, fl ush or rinse area with water thoroughly and consult your doctor.
4. Be sure to perform a call test with the handset on the hook. If you operate the hook switch with the handset on your ear, a sudden call etc. may arrive causing damage to your ear.
5. Do not place your ear near the speaker during use. An unexpected loud sound could cause hearing damage.
6. When cleaning the wall with a high-pressure water sprayer, be careful not to spray on the entrance station. If not observed, it may result in fi re or electric shock.
Keep unit away from water
Be sure to follow the instruction
Notice
• We will under no conditions be liable for any damages or losses resulting from this product's contents or specifi cations.
• We will under no conditions be liable for damage occurring due to the inability to communicate due to malfunctions, problems, or operational errors in this product.
• The unit is inoperative during power failure.
• This system is not intended for life support or crime prevention. It is just a supplementary means of conveying information. Aiphone will under no conditions be liable for loss of life or property which occurs while the system is being operated.
• In areas where broadcasting station antennas are close by, this system may be affected by radio frequency interference.
• Please note the LCD panel, though manufactured with very high precision techniques, inevitably will have a very small portion of its image elements always lit or not lit at all. This is not considered a unit malfunction.
• The unit may get slightly warm, but this is not a malfunction.
• During communication, if you speak before the other person has fi nished talking, your voice may not come through clearly. Conversation will proceed smoothly if you speak when the other person has fi nished talking.
• The entrance station is intended to be mounted on a wall only. It cannot be used on a desktop.
• Available functions and services are limited according to the specifi cations of the installed system.
• If you speak in a fi xed tone, the noise-cut function may judge it to be a noise and cut the transmission, but this is not a malfunction.
• Using a mobile phone or professional-use radio equipment such as walkie­talkie close to the system may cause a malfunction.
• Warm-color lighting shining on the camera may change the tint of the image on the screen.
• The outline of video images displayed may differ from that of the actual person(s) or background, but this is not a malfunction.
• When the unit’s screen is illuminated with strong light, the image looks white or silhouetted. But this is not a unit trouble.
• When outside temperature lowers sharply after rainfall, etc., the inside of the camera may fog up slightly, causing a blurry images, but this is not a malfunction. Normal operation will be restored when moisture evaporates.
• When using a fl uorescent light that shines around the camera, the screen colors may variously change (color rolling), but it is not a malfunction.
• If the entrance station freezes during winter time, the picture may become diffi cult to see or the buttons of the entrance station may not operate.
General Precautions
1. Keep the unit more than 1 m (3.3') away from radio or TV set.
2. Keep more than 20 cm (7-7/8") away from other radio equipment, for example fl oor heating controller, wireless router or cordless telephone, etc. It may cause unwanted noise and video distortion.
3. Talk within 30 cm (12'') from this unit. If you are too far away, it may be diffi cult to hear audio.
4. When installing and using this unit, protect subject's privacy, portrait rights, etc. on your own responsibility.
5. As to other manufacturer's devices (such as sensor, detectors, door releases) used with this system, comply with the Specifi cations and Warranty conditions that the manufacturers or venders present.
6. Avoid using this unit in places under direct sunlight. If it is unavoidable, block out light during use.
7. When putting a hearing aid into T-mode and approaching the unit, the intercom system may be affected by radio frequency interference etc., depending on the installation environment.
8. Please receive and retain all confi guration data from the supplier. If you lose the confi guration data, there are cases where maintenance and after-sales service calls may incur additional setup fees.
10. The area to be monitored by the sensor should be free of obstacles such as ornamental plants.
- 2 -
Table of Contents
PRECAUTIONS ...........................................................2
READ THIS BEFORE USING THE STATIONS
1 SYSTEM CONFIGURATION ........................................ 4
2 NOTES ABOUT USING THIS MANUAL .................... 5
ENTRANCE STATION
1 PART NAMES AND FUNCTIONS ............................... 6
1-1 Entrance station (modular type) ................................. 6
1-2 Entrance station (all-in-one type) ............................... 7
1-3 Indicators .................................................................... 8
2 OPERATIONS ................................................................. 9
2-1 Calling a resident/tenant or guard station .................. 9
Calling with the call switch module....................... 9
Calling with the name scrolling module ................ 9
Calling with the 10 key module ........................... 10
Calling with the all-in-one type entrance station
(GT-DMB-LVN/GT-DMB-N) .............................. 12
2-2 Door release ............................................................. 16
2-3 Other ........................................................................ 16
7 OTHER OPERATIONS ................................................ 45
7-1 Checking for missed calls and calling back .............45
7-2 Receiving an emergency call ................................... 46
8 SETTING........................................................................ 48
8-1 Adjusting display brightness and volumes ............... 48
8-2 Switching to reception mode ................................... 50
8-3 Switching to program mode ..................................... 51
9 UPDATING RESIDENT INFORMATION .................. 52
FOR PROPER USE OF THIS STATION
1 TECHNICAL PRECAUTIONS .................................... 53
2 SPECIFICATIONS ........................................................ 54
3 SOFTWARE LICENSE ................................................56
4 REGULATIONS ............................................................ 57
5 WARRANTY ..................................................................58
GUARD STATION
1 PART NAMES AND FUNCTIONS ............................. 17
1-1 Operation panel ........................................................17
1-2 Indicators .................................................................. 18
1-3 LCD (display) .......................................................... 19
1-4 Button operations ..................................................... 20
2 RECEIVING A CALL ................................................... 22
2-1 Receiving a call ........................................................ 22
3 CALLING (from a tenant building) ......................... 23
3-1 How to search for a unit to call
(from a tenant building) ........................................... 23
3-2 Calling a unit (residential/tenant station)
or guard station ........................................................ 24
3-3 Calling an entrance station ....................................... 29
4 CALLING (from a main building) ............................ 31
4-1 How to select a unit to call
(from a main building) ............................................. 31
4-2 Calling a room (residential/tenant station)
or guard station ........................................................ 32
4-3 Calling an entrance station ....................................... 37
5 OPERATIONS DURING COMMUNICATION .......... 39
5-1 Transferring a call .................................................... 39
5-2 Door release ............................................................. 39
5-3 Operating an optional device ................................... 40
5-4 Viewing and adjusting video at an entrance
station ....................................................................... 41
6 MONITORING ............................................................... 43
- 3 -
READ THIS BEFORE USING THE STATIONS
1
SYSTEM CONFIGURATION
The GT system consists of up to 8 main buildings and 24 tenant buildings.
Main building: A control section that functions as a main entrance, guard station, security center, administration offi ce, etc. A main building includes no residential/tenant stations. You can call up all of the residential/tenant stations and guard stations from an entrance station or guard station in the same system (site). * A station that is not programmed cannot be called. * Modular type entrance stations cannot be installed in a main building. Only all-in-one type can be used.
Tenant building: A section of collective housing. A tenant building includes residential/tenant stations, entrance stations and guard stations. You can call up all of the residential/tenant stations and guard stations from an entrance station in the same tenant building. However, you cannot call stations in another tenant building.
Example
: A system (site) consisting of 1 main and 3 tenant buildings
Residential/tenant stations
Entrance station (modular type)
GT-2C-L/GT-2C (GT-2H-L/GT-2H)
1
2
A
3
C
D
B
F
E
4
G
5
I
J
H
6
L
M
K
O
N
P
7
8
S
T
W
Q
R
9
V
U
Z
X
Y
0
Guard station
GT-MKB-N
GT-1C7-L/ GT-1C7
Entrance station (all-in-one type)
GT-DMB-LVN/ GT-DMB-N
GT-1M3-L/ GT-1M3
Tenant building
GT-1A
GT-1D
Tenant building
Entrance station (all-in-one type only)
GT-DMB-LVN/ GT-DMB-N
Tenant building
Main building
(administration offi ce)
Guard station
GT-MKB-N
- 4 -
READ THIS BEFORE USING THE STATIONS
Coverage of calling, communication and monitoring
The following table shows the coverage of calling, communication, and monitoring from a tenant building and a main building.
NOTE: Performance depends on the settings. If you cannot call even when is indicated, its setting is not confi gured.
Incoming call
Same tenant building Other tenant buildings Same main
building
Other main buildings
Tenant building
Main building
Outgoing call
✓ : Possible — : Impossible
Entrance st. Calling/
Guard st. Calling/
Entrance st. Calling/
Guard st. Calling/
communication
communication Monitoring
communication
communication Monitoring
Entrance st.
Guard st.
-
✓✓ ✓
-
✓✓ ✓ ✓✓ ✓ ✓✓✓✓
✓✓
---------
✓✓
--
About the term "building" and "section":
The term "section" is used on the setting screens of entrance stations and guard stations instead of "building". "Section" and "building" have the same meaning in this manual.
Residential/ tenant st.
e.g. e.g.
Entrance st.
Guard st.
Residential/ tenant st.
Entrance st.
Guard st.
Entrance st.
-- - ----
-- -
-
Setting screen of guard station
CALLING METHOD
NAME / # SEARCH SECT LIST+UNIT # UNIT NUMBER SECT # + UNIT #
✓✓
--
Standby screen of guard station
✓✓✓✓
-
BUILDING #
01
UNIT #
1
-
Guard st.
-
-
2
NOTES ABOUT USING THIS MANUAL
This manual describes how to use the entrance stations and guard stations. The use of them differs depending on the building/section (main or tenant) where they belong. This manual uses the following icons to separate descriptions for the main and tenant buildings.
Icon Meaning
Main building/section
Tenant building/section
- 5 -
ENTRANCE STATION
1
1-1
PART NAMES AND FUNCTIONS
Entrance station (modular type)
Illuminator LED
Audio module
GT-DB-VN
(VIGIK and NFC capable)
GT-DB-V
(VIGIK capable)
GT-DB
Microphone
IN USE LED (orange)
Call indicator (orange)
Talk indicator (orange)
Door release indicator (green)
NFC reader
Camera
Speaker
Camera module
GT-VB
Name scrolling module
GT-NSB
2
3
1
D
A
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
W
8
9
7
P
Q
Z
S
T
V
X
U
Y
R
0
Display
Back search button (or move the cursor to the left)
Forward search button (or move the cursor to the right)
Call button (or set and move forward)
Cancel button (or back)
10 key module
GT-10K
10-key (0 to 9,
, #)
[Combination examples]
Audio only, Direct select type (8 stations)
GT-DB(-V, -VN) + GT-DBP
GF-BP
Audio only, 10 key type
GT-DB (-V, -VN) + GT-DBP
GT-NSB +
GT-10K + GF-10KP
1
A
4
G
J
I
H
7
P
S
T
Q
R
2
B
5
K
8
U
0
C
L
V
3
D
F
E
6
M
O
N
9
W
Z
X
Y
GT-NSP-L
GT-VB + GT-VP
GT-DB (-V,-VN) + GT-DBP
GT-SW + GF-4P
Audio/video, 10 key type
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
8
9
7
W
P
Z
S
T
Q
V
X
U
Y
R
0
Call switch module
GT-SW
Call button
Directory card
Audio/video, Direct select type (8 stations)
GT-VB + GT-VP
GT-DB(-V, -VN) + GT-DBP
GT-NSB + GT-NSP-L
GT-10K + GF-10KP
GT-VB + GT-VP
GT-DB (-V, -VN) + GT-DBP
GT-SW + GF-4P
Audio/video, Direct select type
GT-NSB + GT-NSP-L
GT-SW + GF-4P
- 6 -
ENTRANCE STATION
1-2
Entrance station (all-in-one type)
All-in-one entrance station
GT-DMB-N
(NFC capable)
Talk indicator (orange)
Call indicator (orange)
Door release indicator (green)
Camera
Speaker
10-key (0 to 9, , #)
Microphone
Illuminator LED
Display
IN USE LED (orange)
NFC reader
Back search button (or move cursor to the left)
Forward search button (or move cursor to the right)
Cancel button (or back)
Call button (or set and move forward)
Sensor (If the sensor detects an object, the display will be illuminated.)
All-in-one entrance station
GT-DMB-LVN
(VIGIK and NFC capable, Hearing aid compatible)
Each part and indicator are the same as GT-DMB-N except as shown below (VIGIK).
VIGIK (available in France)
- 7 -
ENTRANCE STATION
1-3
Indicators
122
Indication patterns
Indicator
Status
3
4
Entrance station (modular type) Entrance station (all-in-one type)
34
5
1
5 Display
1 IN USE LED
(orange)
2 Call
indicator
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
L
O
K
H
N
8
9
7
W
P
Z
S
T
V
Q
X
U
Y
R
0
3 Talk
indicator
4 Door
release indicator
Standby Off Off Off Off
System in use
Lit
Call Off
Communication Off Off
Releasing a door Off Off
Off Off Off
Lit
Off Off
Lit
(*1)
Off
(*2)
Monitoring Off Off Off Off
Communication is on hold
Lit
(*1): Lit when door release is activated during call. (*2): Lit when door release is activated during communication. (*3): The display differs depending on the settings.
Off Off Off
Off
Lit
(*1)
(*2)
W E L C O M E
I N U S E
C A L L I N G S M I T H
I N C O M M U N I C A T I O N
D O O R O P E N
W E L C O M E
O N H O L D
(*3)
(*3)
- 8 -
ENTRANCE STATION
2
OPERATIONS
: Main building/section : Tenant building/section
2-1
Calling a resident/tenant or guard station
Calling with the call switch module
1 Press the call button for the unit to be called.
Calling with the name scrolling module
Searching for a unit by scrolling the list
1 In standby mode, press and to display the
target unit # and resident name.
The call indicator will light up and you will hear a call tone.
* Audio guidance will be heard depending on
the settings.
When the call is answered
Communication starts and the talk indicator lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
101 SMITH
* Depending on the settings, only the resident name may be
displayed.
* The list is displayed in order of either unit # or resident name.
2 Press .
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
The call indicator will light up and you will hear a call tone.
* Audio guidance will be heard depending on
the settings.
When the call is answered
Communication starts and the talk indicator lights up.
* Audio guidance will be heard depending on the settings.
- 9 -
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
ENTRANCE STATION
Calling with the 10 key module
Searching for a unit by entering the unit #
1 In standby mode, enter the numbers using [0] to
[9] on the 10-key to display the target unit # and resident name.
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
8
9
7
W
P
Z
S
T
Q
V
X
U
Y
R
0
101 SMITH
2 When the target unit # and resident name is
displayed, press .
The call indicator will light up and you will hear a call tone.
* Audio guidance will be heard depending on
the settings.
* If there is no relevant unit #, "NO ENTRY" is displayed.
NO ENTRY
* When the residential/tenant station that has been called is in
use, the IN USE LED lights up to indicate that the residential/ tenant station cannot be called. (In an expanded system, there may be a case that a residential/ tenant station cannot be called even if the IN USE LED is off.)
Searching for a unit by entering resident name
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
8
9
7
W
P
Z
S
T
Q
V
X
U
Y
R
0
10-key
1 In standby mode, press on the 10-key.
2 When "ENTER A LETTER" is displayed, enter a
letter using the 10-key to display the target unit # and resident name.
The number and resident name for the unit whose initial corresponds to the entered letter will be displayed.
(e.g.) Enter "S".
101 SMITH
* Pressing or searches for the next unit # and resident
name.
* Depending on the settings, only the resident name may be
displayed.
* When the unit # is set to not be displayed, a letter can be
entered without pressing
* If there is no relevant resident name, "NO ENTRY" is
displayed.
NO ENTRY: S
NOTES:
Pressing or for approximately 2 seconds will display
resident names in succession.
If both unit # 111 and 1111 exist, the resident name for unit
111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time.
Stations can be set to display in order by unit #. (The order
starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001.
.
When the call is answered
Communication starts and the talk indicator lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
- 10 -
ENTRANCE STATION
3 When the target unit # or resident name is
displayed, press
The call indicator will light up and you will hear a call tone.
* Audio guidance will be heard depending on the
settings.
When the call is answered
Communication starts and the talk indicator lights up.
* Audio guidance will be heard depending on the settings.
.
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
8
9
7
W
P
Z
S
T
Q
V
X
U
Y
R
0
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
- 11 -
ENTRANCE STATION
Calling with the all-in-one type entrance station
GT-DMB-LVN/GT-DMB-N
The following diagram shows the screen transitions starting from the standby screen. One of the standby screens shown below is preset to this station. Find the standby screen of this station from
to E below and confi rm the transition from it, and refer to the designated page for the
A
calling operation.
NOTE:
If "NO ENTRY" is displayed on the screen, press .
Standby screen
Display OFF (black)
10-key/
Greeting message Picture
WELCOME
10-key/
* Depending on the setting,
the screen turns on automatically when you get closer to this station.
/ Turned on automatically
QUICK LIST
A
INFORMATION
101 SMITH 102 AIPHONE 103 DENTIST 201 LAINE
NUMBER
ALPHA
10-key/
Call operation screen
B
NAME / # SEARCH
HOW TO CALL
1. SELECT UNIT
2. CALL
NUMBER
UNIT LIST
101
SMITH
CALL CANCEL
ALPHA
10-key
UNIT NUMBER
C
HOW TO CALL
1. ENTER UNIT #
2. CALL
10-key 10-key
ENTER UNIT #
UNIT #
ALPHA
CALL CANCEL
SECT LIST +
D
UNIT#
HOW TO CALL
1. BUILDING LIST
2. SELECT
3. ENTER UNIT #
4. CALL
BUILDING LIST
01
CENTRAL TOWER
SELECT CANCEL
To the next page
( C is available in a tenant building/section only.)
or
B
C
SECT# + UNIT#
E
HOW TO CALL
1. ENTER
BLDG. #
2. SELECT
3. ENTER UNIT #
4. CALL
ENTER BUILDING #
BUILDING #
ALPHA
ENTER CANCEL
To the next page
B
To the next page
C
- 12 -
To the next page
D
To the next page
E
ENTRANCE STATION
A
Confi rming the target unit in the quick list
Unit # and resident names frequently called are preset to be displayed in the quick list.
* Up to 4 units can be displayed.
INFORMATION
Unit #
Resident name
101 SMITH 102 AIPHONE 103 DENTIST 201 LAINE
NUMBER
ALPHA
1 In standby mode, press and to display the
target unit, or 10-key to change the standby screen.
or
The "UNIT LIST" screen B or "ENTER UNIT #" screen C is displayed.
C
Entering unit #
NOTE: Entering unit # can only be performed on this screen.
Entering resident name is not possible.
HOW TO CALL
1. ENTER UNIT #
2. CALL
When the target unit number is numerals
only
1 In standby mode, enter numbers using [0] to [9]
on the 10-key to display the target unit #.
* The 10-key can be used even after pressing or .
ENTER UNIT #
UNIT #
ALPHA
CALL CANCEL
* Depending on the system, only the resident name may be
displayed.
* If you have entered a wrong number, press to return to
standby mode.
2 Follow the operating procedure of either
or C
B
depending on the displayed screen.
is available in a tenant building/section only.
C
*
B
Searching for a unit in the unit list
HOW TO CALL
1. SELECT UNIT
2. CALL
NUMBER
ALPHA
1 In standby mode, press and or 10-key to
display the target unit # and resident name.
UNIT LIST
101
SMITH
CALL CANCEL
or
The 10-key can be used to enter unit #, or by pressing , then the 10-key can be used to enter letters (resident name).
* Depending on the settings, only the resident name may be
displayed.
* The list is displayed in order of either unit # or resident name. * If you have entered a wrong number, press to return to
standby mode.
2 When the target unit is displayed, press .
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of
for details.
2-1
2 When the target unit # is displayed, press .
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of
for details.
2-1
When the target unit number is alphanumeric
1 In standby mode, press on the 10-key.
* The 10-key can be used even after pressing or .
ENTER UNIT #
UNIT #
NUMBER ALPHA
CALL CANCEL
2 Enter letters using the 10-key to display the
target unit #.
* Refer to the next page for how to enter letters.
3 When the target unit # is displayed, press .
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of
- 13 -
for details.
2-1
ENTRANCE STATION
How to enter letters
(e.g.) Entering "CATHY"
1. To enter "C", press
2. Press
once.
(*1)
three times.
3. To enter "A", press once.
4. To enter "T", press
5. To enter "H", press
6. To enter "Y", press
(*1): This step is needed for entering different letters with the same
key sequentially.
once.
twice. three times.
To enter a special character
, : Press once.
- : Press . : Press / : Press Space : Press Æ : Press Ø : Press Å : Press
* If you have entered a wrong letter, press to return to
standby mode.
twice.
three times.
four times.
fi ve times.
six times. seven times. eight times.
D
Searching for a building in the building list
and entering unit #
HOW TO CALL
1.
BUILDING LIST
2.SELECT
3.ENTER UNIT #
4.CALL
1 In standby mode, press and to display the
target building number and name.
BUILDING LIST
01
CENTRAL TOWER
SELECT CANCEL
2 When the target building is displayed, press .
3 Enter numbers or letters using the 10-key to
display the target unit #.
* For entering numbers or letters, follow steps 1 and 2 of
- "When the target unit number is numerals only"
C
"When the target unit number is alphanumeric".
or
ENTER UNIT #
01
CENTRAL TOWER UNIT # 101
CALL
ALPHA
4 When the target unit # is displayed, press .
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of
for details.
2-1
- 14 -
ENTRANCE STATION
E
Entering a building # and unit #
HOW TO CALL
1.
2.SELECT
3.ENTER UNIT #
4.CALL
ENTER BLDG#
When the target unit is successfully called
The call indicator will light up and you will hear a call tone.
* Audio guidance will be heard depending on the settings.
1 In standby mode, enter numbers or letters using
the 10-key to display the target building.
* For entering numbers or letters, follow steps 1 and 2 of
-
"When the target unit number is numerals only"
C
or
"When the target unit number is alphanumeric".
ENTER BUILDING #
BUILDING #
01
ALPHA
ENTER CANCEL
2 When the target building number is displayed,
press .
3 Enter numbers or letters using the 10-key to
display the target unit #.
* For entering numbers or letters, follow steps 1 and 2 of
-
"When the target unit number is numerals only"
C
"When the target unit number is alphanumeric".
or
ENTER UNIT #
BUILDING # 01 UNIT # 101
CALL
ALPHA
When the call is answered
Communication starts and the talk indicator lights up.
* Audio guidance will be heard depending on the settings.
When the door is released
The door release indicator lights up.
* Audio guidance will be heard depending on the settings.
NOTES:
If "DENIED" is displayed or returns to standby mode,
the entered unit #/resident name is not registered.
Enter the target unit # exactly. Otherwise, "DENIED" is
displayed or returns to standby mode.
If both unit # 111 and 1111 exist, the resident name for
unit 111 will be displayed when 1, 1, 1 is entered, and the resident name for unit 1111 will be displayed if 1 is entered one more time.
Stations can be set to be displayed in order by unit #.
(The order starts with the lowest digit from 0 to 9 and then the order goes by letter.) In cases where unit # such as A101, A201, A901, A1001, and B101 exist, the order starts with the lowest digit and goes in the order A101, A201, A901, B101, A1001.
4 When the target unit # is displayed, press .
The target unit is called.
* Refer to "When the target unit is successfully called"
at the end of
for details.
2-1
- 15 -
ENTRANCE STATION
2-2
Door release
Door release by using the access code
* The access code is preset by the system installer or
administrator.
1 In standby mode, enter [#] and then the access
code (4 to 6 digits) using [0] to [9] on the 10-key.
[Modular type]
2
3
1
A
D
F
C
B
E
5
4
6
M
G
J
I
L
O
K
H
N
8
9
7
W
P
Z
S
T
Q
V
X
U
Y
R
0
(e.g.) When the access code is "4567", enter "#", "4", "5", "6", "7".
The door is released.
[All-in-one-type]
Door release by an NFC-compliant IC card, etc.
A card incorporated with an NFC tag can be used to release a door. To use, the ID of the NFC tag must be registered as a door release code.
1 Pass an NFC-compliant IC card over the NFC
reader.
[Modular type]
NFC reader
* Put the card within 10 mm of the NFC reader. Otherwise, the
code may not be read correctly.
[All-in-one-type]
The door release indicator lights up.
Audio guidance will be heard depending
on the settings.
* If there is no relevant number, "DENIED" is displayed. * Door release is enabled even while the IN USE LED is lit.
2-3
* Calling from an entrance station is disabled while the IN USE LED is lit.
Wait until the IN USE LED turns off.
Other
The door is released.
The door release indicator lights up.
Audio guidance will be heard depending
on the settings.
* Door release is enabled even while the IN USE LED is lit.
NOTE: Do not overlap IC cards when passing them over the
NFC reader. The code may not be read correctly.
NOTE: For a multi building system with lift control, if you unlock from a
room and terminate call at the same time, the entrance station may not unlock properly.
- 16 -
GUARD STATION
1
PART NAMES AND FUNCTIONS
1-1
Operation panel
Multi-function buttons
LIGHT
VIDEO CALL
LIST
SETTING
10-key (0 to 9, , #)
Handset
Color LCD monitor (Display)
Speaker
ZOOM
WIDE
ADJUST
Status LED (orange)
Indicates the current status of this station by lighting up or fl ashing on/off in orange (while initializing the system, being called, communicating, etc.).
NFC reader
Reset button
Option button
MONITOR button
TALK button
ADJUST button
ZOOM/WIDE button
(up)
(right)(left)
(down)
Door release (
Microphone
OFF button
) button
- 17 -
GUARD STATION
1-2
Indicators
Indication patterns
Status
Indicator
Standby Off
Standby (Call tone volume: off)
Standby (Reception mode: on)
This station is in use by another station (this station is inoperable)
Being called by an entrance station Fast flashing
Being called by a door station Normal flashing
Being called by a door bell Fast flashing
Monitoring an entrance station
6 Status LED (orange)
Long interval flashing
Slow flashing
Off
Lit
(0.5 sec.)
(0.5 sec.)
(0.5 sec.)
(1 sec.)
(0.5 sec.)
6
ZOOM
ADJUST
WIDE
(5.5 sec.)
(2.5 sec.)
(0.5 sec.)
(1 sec.)
(1 sec.)
Communicating with an entrance station
Calling another guard station or residential/tenant station (including in reception mode)
Lit
Fast flashing
(0.5 sec.)
Sounding an emergency alarm Fast flashing
(0.5 sec.)
(0.5 sec.)
A new list of missed calls from residential/tenant stations has arrived
Slow flashing
Error indication Off
(An error message is displayed.)
Communication is on hold Off
- 18 -
(0.5 sec.)
(0.5 sec.)
(2.5 sec.)
Loading...
+ 40 hidden pages