Aiphone GF-1DKS User Manual

Tenant Station with Extra Switch Contact
- INSTRUCTIONS -
The GF-1DKS and GF-1MDKS are tenant stations for the GF system with the Concierge and/or Panic Call feature. The top button is made functional with a switch contact installed. The dry contact is Normally Open and can be used for individual door release activation, elevator call-up, or any function that can be activated with a contact closure.
WIRING DIAGRAM:
(GF-1DKS)
To Bus Line
(See GF Instructions)
WIRING DIAGRAM:
(GF-1MDKS)
To Bus Line
(See GF Instructions)
GF-1DKS
R1 R2
GF-1MDKS
B1 B2 R1 R2
Yel Yel
Yel Yel
N/O Dry Contact
Locate 2 YELLOW wires inside unit. Connect external system to be triggered to these wires. All other connections are per standard GF installation instructions.
N/O Dry Contact
SPECIFICATIONS:
Contact Rating:0.5A at 24V DC Communication:Handset from tenant to entrance panel Hands free from entrance to tenant Calling:Electronic ring tone from entrance panel Differentiated ring tone from individual doorbell Wiring:2-conductor common bus wire for Audio (GF-1DKS) Plus a separate 2-cond. common bus wire for Video (GF-1MDKS) Plus additional independent 2-cond. wire from each unit’s extra switch to external system Wiring Distance:GF-BC to farthest GF-1DKS or GF-1MDKS: 980' with 20AWG Total cumulative wire distance must not exceed 1.5 miles (8,200') with 20AWG Wire: Aiphone 872002 for Audio; 871802 for Video Dimensions:GF-1DKS: 7-7/8” H x 3-1/2” W x 2-1/2” D GF-1MDKS: 8-1/4” H x 8-1/2” W x 2-3/4” D
GF-1DKS
Additional switch is activated with top button.
GF-1MDKS
Additional switch is activated with top button.
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071