Aiphone DE-UR User Manual

83435300 0595©
TD Series

DOOR STATION ADAPTOR

Model: DE-UR

INSTALLATION & OPERATION MANUAL

® AIPHONE

SYSTEM OUTLINE & COMPONENTS

----------------------------------------------------

Package contents

Door station adaptor (DE-UR) Packet of screws Installation & Operation Manual
★ TD-H or TD-Z system is
powered by a PS-12A (PS­12C), which should be located in the middle point of cable run. Install a DE-UR(s) near the power supply.

■ Components available * Intercoms TD-H Series: TD-3H/B, TD-6H/B, TD-12H/B & TD-24H/B. (TD-H/A Series also)

TD-Z Series: TD-6Z/A & TD-12Z/A loop-wired. Audio door station only.
' Intercom
TD-6H/B
TD-12Z/A
• Audio door stations
IF-DA lE-JA lE-DC
lE-NC
Video door stations
MY-CA MY-DC MY-FA
MY-DS
Others : lE-FY (not available In USA)

NAMES AND FEATURES

Call tone selector
Terminal block
160mm 6-1/4"
Others : MY-DG, MY-EA It can be a combination of MY-CA (in MYW-CA enclosure) and IF-DA.
For TD-H to have 2 door stations, DE-UR employs a switch (preset to A) to change slow intermittent tone to
faster intermittent tone.

■ Features

* Surface-mount with 83.5mm, 3-5/16" guide.
* Call tone modulating circuits, 2-1/2-sec. timed. * Powered by using system's PS-12/V12C power supply. * Includes door release control terminals.

3 PRECAUTIONS ON INSTALLATION & WIRING

/t\ CAUTION

★ Do not connect any terminal on any unit to AC power lines. ★ Unplug all power supplies while making wiring connections on any audio and video equipment.
★ DE-UR is an adaptor for indoor installation only. Follow precautions as stated in the Manuals packed with
TD-H and MY-CU monitor.
★ Locate DE-UR unit(s) closely to power supply PS-12A (PS-12C) of TD-H orTD-Z system, so as to be fed DC12V
from it.
★ Wiring to EL-9S door release must run in a separate jacketed cable and apart from intercom wiring.

■ Before installing DE-UR, the contents of this Manual must be thoroughly read and understood.

t WIRING

■ Terminal block layout

■ DE-UR & power supply location

It is suggested to mount a DE-UR unit(s) in a recessed area, together with power supply PS-12A (PS-12C) and
video adaptor, etc. Select a location that allows limited access only by qualified personnel, and is dust-free
environment possible.
---------------------------------------------------------------------------------------------------
+
-"M
o
1 ^
O
O
Audio door station
EL, EL : Dry closure contact for door release
: 12V DC power
1,2: Door station connection
C : Selective communication from TD-H/TD-Z masters D : Call-in tone to TD-H masters (or TD-Z)
PanTiit video door station 2 PanTiit doors pius 1 camera
-2-

Wiring

1. One audio lE/IF Series
2. Two audio lE/IF Series
IF-DA
DE-UR
4 wires to to TD-H(TD-Z) (max. 12)
3. One PanTilt MY Series (plus one audio)
IF-DA IF-DA 1 2
DE-UR DE-UR
4. Two PanTilt MY Series
no. no. D
5 wires to to TD-H(TD-Z) (max. 12)
-3-
MOUNTING
DE-UR chassis, after separated, mounts with
83.5mm, 3-5/16” guide.
1. Opening the cover, loosen the bottom screw.
2. Lift front case off the prongs of chassis, and disconnect DE-UR.
3. Mount the chassis to wall or board at 2 points.
4. Make wire terminations for each door station, TD-H station, and PS-12A(12C) power supply.
5. Reconnect and mount DE-UR front case to chassis.
I
SPECIFICATIONS
* Power source: * Current consumption: * Call tone:

Wiring: To audio lE/IF door 2 conductors (parallel)

★ DE-UR must be fed 12V DC from PS-12A (PS-12C) or via near DE-UR. See page 2.
DC 12V, supplied by a power supply PS-12A (PS-12C) of TD-H (TD-Z) system.
120mA max. Intermittent tremolo, 2-1/2-timed
To TD-H/B stations 4 conductors (D, C and +, -)
DE-UR DE-UR
Vto TD-H

Wiring distance:

From DE-UR to door station
Diameter
Distance AWG 22AWG 20AWG Distance 500' 750' 1,200'
0.65mm 150m 230m
0.8mm 1.0mm 360m
18AWG
From DE-UR to PS-12A/12C
Diameter
Distance 10m 15m 20m AWG 22AWG Distance
0.65mm 0.8mm 1.0mm
20AWG
30'
50'
DE-UR EL, EL terminals capacity: DC 30V, 1A or AC 30V, 1 A. Dimensions: (H x W x D) 160 x 150 x 45 (mm). 6-1/4"H x 6"W x 1-3/4"D Weight: 320g (0.71 lbs.) approx.
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the product. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls.
-i*
WARRANTY
18AWG
65'
•i*
•f*
Aiphone Co., Ltd., Nagoya, Japan Aiphone Corporation, Bellevue, WA, USA
DE-UR-I(E) 0595E