Aiphone DE-UR User Manual

83435300 0595©
TD Series

DOOR STATION ADAPTOR

Model: DE-UR

INSTALLATION & OPERATION MANUAL

® AIPHONE

SYSTEM OUTLINE & COMPONENTS

----------------------------------------------------

Package contents

Door station adaptor (DE-UR) Packet of screws Installation & Operation Manual
★ TD-H or TD-Z system is
powered by a PS-12A (PS­12C), which should be located in the middle point of cable run. Install a DE-UR(s) near the power supply.

■ Components available * Intercoms TD-H Series: TD-3H/B, TD-6H/B, TD-12H/B & TD-24H/B. (TD-H/A Series also)

TD-Z Series: TD-6Z/A & TD-12Z/A loop-wired. Audio door station only.
' Intercom
TD-6H/B
TD-12Z/A
• Audio door stations
IF-DA lE-JA lE-DC
lE-NC
Video door stations
MY-CA MY-DC MY-FA
MY-DS
Others : lE-FY (not available In USA)

NAMES AND FEATURES

Call tone selector
Terminal block
160mm 6-1/4"
Others : MY-DG, MY-EA It can be a combination of MY-CA (in MYW-CA enclosure) and IF-DA.
For TD-H to have 2 door stations, DE-UR employs a switch (preset to A) to change slow intermittent tone to
faster intermittent tone.

■ Features

* Surface-mount with 83.5mm, 3-5/16" guide.
* Call tone modulating circuits, 2-1/2-sec. timed. * Powered by using system's PS-12/V12C power supply. * Includes door release control terminals.

3 PRECAUTIONS ON INSTALLATION & WIRING

/t\ CAUTION

★ Do not connect any terminal on any unit to AC power lines. ★ Unplug all power supplies while making wiring connections on any audio and video equipment.
★ DE-UR is an adaptor for indoor installation only. Follow precautions as stated in the Manuals packed with
TD-H and MY-CU monitor.
★ Locate DE-UR unit(s) closely to power supply PS-12A (PS-12C) of TD-H orTD-Z system, so as to be fed DC12V
from it.
★ Wiring to EL-9S door release must run in a separate jacketed cable and apart from intercom wiring.

■ Before installing DE-UR, the contents of this Manual must be thoroughly read and understood.

t WIRING

■ Terminal block layout

■ DE-UR & power supply location

It is suggested to mount a DE-UR unit(s) in a recessed area, together with power supply PS-12A (PS-12C) and
video adaptor, etc. Select a location that allows limited access only by qualified personnel, and is dust-free
environment possible.
---------------------------------------------------------------------------------------------------
+
-"M
o
1 ^
O
O
Audio door station
EL, EL : Dry closure contact for door release
: 12V DC power
1,2: Door station connection
C : Selective communication from TD-H/TD-Z masters D : Call-in tone to TD-H masters (or TD-Z)
PanTiit video door station 2 PanTiit doors pius 1 camera
-2-
Loading...
+ 2 hidden pages