Agilent U2761A Data Sheet

Agilent
U2761A USB Modular Function/Arbitrary Waveform Generator
Data Sheet
A
Overview
20 MHz Sine and Square waveforms
Sine, Square, Ramp, Triangle, Pulse and DC waveforms
14-bit, 50 MSa/s, 64 k-points Arbitrary waveforms
AM, FM, PM, ASK, FSK, and PSK modulation types
40 mVpp to 5 Vpp amplitude range (into 50 ohm load)
Pulse generation
Easy-to-use bundled software
Arbitrary waveform editor
Command logger function
Hi-Speed 2.0, USBTMC 488.2 standards
The Agilent U2761A is a 20 MHz USB modular function generator with Arbitrary waveform and pulse generation capability. It can operate as a standalone or modular unit when used with the U2781A USB modular instrument chassis.
Various features of the U2761A
Latest DDS technology adoption for more stable and accurate • output signal Easy-to-use arbitrary waveform editor for easy customization of • waveform generation Built-in modulation capability eliminates the need for a separate • modulation source Pulse generation up to 5 MHz with variable period, pulse width, and • amplitude that are ideal for wide variety of applications
Wide range of Application Development Environment (ADE) • compatibility Low start-up cost with standalone capability • Flexibility in expanding your application when using
it as modular unit with the U2761A
Command logger function offered in the• bundled software allows easy command conversion into VEE programs
tandalone capability our application when using
he U2761 n offered in the
easy command
rams
Direct digital waveform
The U2761A adopts the latest direct digital synthesis (DDS) technology that digitally creates arbitrary waveforms and frequencies from a single and fi xed frequency source. DDS offers the precision of digitally controlled logic—reducing the complexity of the generator while increasing the stability. Thus, allowing you to have
a stable, accurate output signal for clean, low distortion sine waves and square waves with fast rise and fall time up to 20 MHz and linear ramp waves up to 200 kHz.
Arbitrary waveform editor
With every purchase of the U2761A, it is bundled with an easy-to-use application software, the Agilent Measurement Manager. This application allows customization of waveforms generation.
Pulse generation
The U2761A can generate pulses from 500 μHz to 5 MHz. With variable period, pulse width, and amplitude parameters, the U2761A is ideally suited to a wide variety of applications
requiring fl exible pulse width signals.
Internal modulation
Internal AM, FM, PM, ASK, FSK, and PSK modulation makes it easy to modulate waveforms without the need for a separate modulation source. Linear and logarithmic sweeps are also built in, with sweep rates selectable from 1 ms to 500 s.
2
Quick and easy to begin with
The USB 2.0 interface provides easy connectivity and setup that allows automatic detection of the U2761A. With quick and easy USB connectivity, the U2761A is ideal for academic and testing environment. The USBTMC
488.2 standard makes the U2761A compatible with any system that comes with USB ports.
Flexible standalone or modular capability
The U2761A is uniquely designed with fl exibility to function standalone or as a modular unit. The standalone PC-based unit allows you to have low start-up cost.
ADE compatibility
The U2761A is compatible with a wide range of ADEs. This minimizes development time because developers can program directly using the SCPI commands.
Listed below are the popular development environments and tools that the U2761A is compatible with:
• Agilent VEE and Agilent T&M Toolkit
• Microsoft® Visual Studio .NET, C/C++ and Visual Basic 6
• LabView®
• MATLAB®
Easy-to-use AMM offers command logger function
Better yet, Agilent Measurement Manager application software provides a quick and easy means to confi gure and control the device. This enhances productivity because it allows users to start performing measurement promptly without needing to write any programming codes.
The Agilent Measurement Manager also comes with a command logger function that lets you capture commands that can be easily converted to VEE programs for VEE users.
Product Outlook and Dimensions
Front View
Rear View
41.00 mm
Standard Shipped Item
12 V, 2 A AC/DC Adaptor Power Cord USB Standard-A to Mini-B Interface Cable L-Mount Kit (used with modular instrument chassis) Agilent Automation-Ready CD (contains the Agilent IO Libraries Suite) Agilent USB Modular Products Quick Start Guide Agilent USB Modular Products Reference CD-ROM Agilent Measurement Manager Quick Reference Card
Certifi cate of Calibration
Top View
180.00 mm
15.00 mm
117.00mm
Optional Accessories
1.5 m BNC Coax Cable USB Secure Cable
3
System Requirements
PROCESSOR
1.6 GHz Pentium® IV or higher
OPERATING SYSTEM
Windows ® XP Professional or Home Edition (Service Pack 1 or later), or Windows 2000 Professional (Service Pack 4 or later)
BROWSER
Microsoft® Internet Explorer 5.01 or higher
AVAILABLE RAM
512 MB or higher recommended
HARD DISK SPACE
1 GB
VIDEO
Super VGA 800×600 (1024×768 recommended)
PREREQUISITES
Agilent IO Libraries 14.2 or higher (version 15.0• Agilent T&M Toolkit 2.1 Runtime version 2.1
Agilent T&M Toolkit Redistributable Package 2.1 patch• Microsoft .NET Framework version 1.1 and 2.0
1 Available in Agilent Automation-Ready CD. 2 Bundled with Agilent Measurement Manager application software installer.
1
recommended)
2
2
2
Product Characteristics and General Specifi cation
REMOTE INTERFACE
Hi-Speed USB 2.0• USBTMC 488.2 Class Device
POWER CONSUMPTION
+12 VDC, 2 A
Isolated ELV power source
OPERATING ENVIRONMENT
Operating temperature from 0 °C to 50 °C• Operating humidity at 20% to 85% RH (non-condensing)• Altitude up to 2,000 meters • Pollution degree 2• For indoor use only
STORAGE COMPLIANCE
Storage temperature from –20 °C to 70 °C• Storage humidity at 5% to 90% RH (non-condensing)
SAFETY COMPLIANCE
Certifi ed with:
IEC 61010-1:2001/ EN61010-1:2001 (2nd Edition)• Canada : CAN/CSA-C22.2 No. 61010-1-04• USA: ANSI/UL 61010-1:2004
EMC COMPLIANCE
IEC 61326-2002/ EN 61326:1997+A1:1998+A2:2001+A3:2003• Canada : ICES-001:2004• Australia/New Zealand: AS/NZS CISPR11:2004
SHOCK & VIBRATION
Tested to IEC/EN 60068-2
IO CONNECTOR
BNC Connector
DIMENSION (WxDxH)
117.00 mm x 180.00 mm x 41.00 mm (with bumpers)
105.00 mm x 175.00 mm x 25.00 mm (without bumpers )
WEIGHT
528 g (with bumpers)• 476 g (without bumpers)
WARRANTY
One year
4
Product Specifi cations and Measurement Characteristics
WAVEFORMS
Standard Sine, Square, Ramp, Triangle, Pulse, DC
Built-in arbitrary Exponential Rise, Exponential Fall, Negative Ramp
WAVEFORM CHARACTERISTICS
SINE
Frequency range 1 μHz to 20 MHz (1 μHz resolution)
Amplitude fl atness 1 (relative to 1 kHz)
Harmonic distortion
Total harmonic distortion
Spurious (Non-harmonic) output
Phase noise (10 kHz offset) –115 dBc/Hz
SQUARE
Frequency range 1 μHz to 20 MHz
Rise/Fall time <18 ns, 10 to 90% terminated load (50 Ω)
Overshoot <2%
Variable duty cycle 20% to 80% (up to 10 MHz)
Asymmetry (@ 50% duty) 1% of period + 5 ns
Jitter (RMS) >50 kHz = 1 ns + 100 ppm of period
RAMP, TRIANGLE
Frequency range 1 μHz to 200 kHz (1 μHz resolution)
Linearity <0.2% of peak output
Programmable Symmetry 0% to 100%
PULSE
Frequency range 500 μHz to 5 MHz (1 μHz resolution)
Pulse width (period ≤ 10 s) 40 ns minimum, 10 ns resolution
Overshoot <3%
Jitter (RMS) 300 ps + 0.1 ppm of period
ARBITRARY
Frequency range 1 μHz to 200 kHz (1 μHz resolution)
Waveform memory depth 64 kSa
Amplitude resolution 14 bits/sample (including sign)
Sampling rate 50 MSa/s
Minimum rise/fall time 35 ns
Linearity <0.2 % of peak output
Settling Time <250 ns to 0.5% of fi nal value
Jitter (RMS) 10 ns + 30 ppm
2
2
<100 kHz 0.2 dB
100 kHz to 1 MHz 0.35 dB
1 MHz to 20 MHz 0.7 dB
Frequency range <1 Vpp ≥1 Vpp
DC to 20 kHz –70 dBc –60 dBc
20 kHz to 100 kHz –65 dBc –60 dBc
100 kHz to 1 MHz –50 dBc –45 dBc
1 MHz to 20 MHz –40 dBc –35 dBc
DC to 20 kHz 0.10%
3
DC to 1 MHz –65 dBc
1 MHz to 20 MHz –65 dBc + 6 dB/octave
(Typical)
(1 μHz resolution)
40% to 60% (up to 20 MHz)
50 kHz = 10 ns + 100 ppm of period
(Typical)
5
COMMON CHARACTERISTICS
AMPLITUDE
Range 40 mVpp to 5 Vpp (Into 50 Ω load)
80 mVpp to 10 Vpp (Into open circuit)
1
Accuracy (across 50 Ω load at 1 kHz)
Units Vpp, Vrms. dBm
Resolution 4 digits
DC OFFSET
Range (peak AC + DC) ± 2.5 V (Into 50 Ω load)
1
Accuracy (across 50 Ω load)
Amplitude Limit Amplitude + Offset limit to witthin ±2.5 V range across 50 Ω
MAIN OUTPUT
Impedance 50 Ω load (Typical)
Isolation At least 42 Vpk to earth
Protection Short-circuit protected, overload automatically disables main
INTERNAL FREQUENCY REFERENCE
Accuracy
4
EXTERNAL FREQUENCY REFERENCE
Input Lock range Amplitude level Impedance Lock time
Output Frequency Amplitude Level Impedance
Phase Offset Range Resolution Accuracy
±1% of setting ±5 mV (
±10 mV @ Hi-Z)
± 5 V (Into open circuit)
±2% of offset setting ±1% of amplitude ±5 mV (±10 mV @Hi-Z)
load or ±5 V across open circuit
output
± 8 ppm in 1 year
10 MHz ±170 Hz 500 mVpp to 5 Vpp 50 Ω
AC coupled
<2 s
10 MHz 632 mVpp (Typical) Return loss 10 dB (Typical) at 10 MHz
+360 ° to –360 °
0.01 ° 20 ns
TRIGGER CHARACTERISTICS
TRIGGER INPUT
Input Level TTL compatible
Slope Rising and Falling, Selectable
Pulse width >100 ns
Input impedence >10 k
Latency <500 ns
Jitter (RMS) 6 ns (3.5 ns for Pulse)
TRIGGER OUTPUT
Output Level TTL compatible into ≥1 kΩ
Pulse width >400 ns
Output impedance 50
Fanout 4 TTL
Rise time ≤20 ns
6
Ω, DC coupled
Ω (Typical)
MODULATION
Modulation scheme Internal, AM, FM, PM, FSK, PSK, ASK
AM
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation Sine, Square, Ramp, Arbitrary (2 mHz to 20 kHz)
Depth 0.0% to 100.0%
FM
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation Sine, Square, Ramp, Arbitrary (2 mHz to 20 kHz)
Deviation 1 Hz to 500 kHz
PM
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation Sine, Square, Ramp, Arbitrary (2 mHz to 20 kHz)
Deviation 0.0 ° to 360.0 °
FSK
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation 50% duty cycle square (2 mHz to 100 kHz)
PSK
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation 50% duty cycle square (2 mHz to 100 kHz)
Deviation 0.0 ° to 360.0 °
ASK
Carrier waveforms Sine, Square, Ramp, Arbitrary
Source Internal
Internal modulation 50% duty cycle square (2 mHz to 100 kHz)
SWEEP CHARACTERISTICS
Waveforms Sine, Square, Ramp, Arbitrary
Type Linear or Logarithmic
Direction Up or Down
Sweep time 1 ms to 500 s
Trigger Single, External, or Internal
1 Add 1/10th of output amplitude and offset specifi cation per °C for operation outside the range of 18 °C to 28 °C. 2 DC offset set to 0 V. 3 Spurious output at low amplitude is –70 dBm, typical. 4 Add 1 ppm/°C (average) for operation outside the range of 18 °C to 28 °C.
7
Agilent Email Updates
t
www.agilent.com/fi nd/emailupdates
Get the latest information on the products and applica­tions you select.
Agilent Direc
www.agilent.com/fi nd/agilentdirect
Quickly choose and use your test equipment solutions with confi dence.
Agilent
Open
www.agilent.com/fi nd/open
Agilent Open simplifi es the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system­ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development.
Remove all doubt
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confi dence in your measurements.
Agilent offers a wide range of additional expert test and measurement services for your equip­ment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management.
For more information on repair and calibration services, go to
www.agilent.com/find/removealldoubt
www.agilent.com
For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:
www.agilent.com/find/contactus
Phone or Fax
United States:
(tel) 800 829 4444 (fax) 800 829 4433
Canada:
(tel) 877 894 4414 (fax) 800 746 4866
China:
(tel) 800 810 0189 (fax) 800 820 2816
Europe:
(tel) 31 20 547 2111
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (080) 769 0800 (fax) (080) 769 0900
Latin America:
(tel) (305) 269 7500
Taiwan:
(tel) 0800 047 866 (fax) 0800 286 331
Other Asia Pacifi c Countries:
(tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com
Revised: 11/08/06
Product specifi cations and descriptions in this document subject to change without notice.
© Agilent Technologies, Inc. 2008 Printed in USA, May 22, 2008 5989-7975EN
Loading...