Agilent U1604A Data Sheet

Agilent U1600A Series Handheld Digital Oscilloscopes
Features
•Three-in-one solution : Dual channel oscilloscope, True RMS DMM and Real-Time Data Logger
•Large 4.5” color LCD display
•Up to 200 MSa/s sampling rate
•125,000 points/channel of waveform memory depth (maximum record length)
•6000 count DMM resolution with 22 automatic measurement functions
•11 built-in measurement functions including voltmeter, ohmmeter and auxiliary meter
•Zoom and Dual Waveform Math functions (additional FFT function with four windowing techniques available in U1604A)
•Full remote control and data transfer via PC Link application software
•USB 1.1 full speed interface connectivity
•Multi-language Quick Help support
Introduction
The U1600A series handheld digital oscilloscope has a 4.5-inch LCD color display that is capable of clearly distinguishing waveforms between two channels. This U1600A series offers a high performance troubleshooting and quality assurance tool for technical professionals in the installation, maintenance, service and automotive industries. The U1600A series consists of two models: U1602A — 20 MHz oscilloscope and U1604A — 40 MHz oscilloscope. Each model has real time sampling rate of up to 200 MSa/s. Users can use the Dual Waveform Math (DWM) and Fast Fourier Transform (FFT) functions (in U1604A) to perform quick waveform analysis in both time and frequency domains. The built-in 6000 resolution count true RMS digital multimeter (DMM) comes with auto-range feature that gives users the flexibility to perform quick and accurate meter measurement functions inclusive o f voltage, resistance and auxiliary
measurements. In addition to this, the U1600A series also comes standard with data logging functionality that allows users to consolidate a sequence of data points for data recording purposes.
A scope, true RMS DMM and real­time data logger in one instrument
The U1600A series is a robust, high performance and reliable handheld waveform and meter measurement tool for today’s challenging industrial environment. This instrument not only provides full featured oscilloscope functions, but a 6000 count true RMS DMM with real-time data logger. The DMM consists of 11 measurement functions including voltmeter (for DC voltage, AC voltage, true RMS AC + DC voltage measurements), ohmmeter (for 2­wire resistance, capacitance, diode and continuity test) and auxiliary meter (for temperature, ampere, humidity and pressure measurements).
Delivering the most functionality and performance in their class of handheld oscilloscope
Data Sheet
2
Clearly distinguish your waveform
The U1600A series models comes with a color display to allow you to quickly and clearly identify your signal between two channels. The large size LCD display – 4.5” with 320 x 240 resolution extends the simplicity and makes it easier for you to see more information.
Capture signal deviations, glitches and dropouts effectively
The U1600A series offers the best product specification for users. This instrument provides real-time sampling rate of up to 200 MSa/s – 8 times the sampling rate of competitive handheld digital oscilloscope in its class. Use U1600A series to capture both instantaneous and repetitive signal anomalies effectively.
High precision zoom-in capability in deep memory
Up to 250 times the memory depth of competitive handheld digital oscilloscope in this class. With 125 kilobytes of memory depth per channel, now you can capture long time spans and non-repeating signals while maintaining a maximum sampling rate of 200 MSa/s. Deep memory allows you to quickly zoom in the segment of interest and uncover even the most subtle details of the signal at a given time base setting.
Isolate and analyze the signal you want to see
The U1600A series comes with flexible triggering capabilities that allows you to isolate and capture the condition you want to characterize. The advanced triggering includes edge, pulse width, pattern and video signal triggering that are essential for quick isolation of critical events.
Figure 1 High-definition of color resolution in large 4.5” LCD display allows you to quickly distinguish and identify your signals and observe signal activity.
Figure 2 With deep memory of 125 kilobytes per channel, use the zoom-in function to magnify signal to the segment of your interest and scrutinize subtle details of your signal.
Before zoom
After zoom
3
FFT (U1604A only) and Dual Waveform Math functions for waveform analysis
Besides the standard Dual Waveform Math (DWM) function in U1600A series, the U1604A model is equipped with an FFT (Fast Fourier Transform) function. This function allows you to view the waveform in frequency domain using four windowing techniques (Rectangular, Hanning, Hamming, Blackman­Harris). Use the DWM function to perform math functions for signal addition and subtraction from multiple channels.
Easy, straightforward connectivity
The U1600A series expands the oscilloscope’s capability with the PC Link application software that caters for data gathering, storage and documentation needs from instrument via USB 1.1 full speed. You can control the intstrument remotely f rom PC, retrieve your waveform and print it using a connected printer. This PC Link application software is bundled with the purchase of any U1600A series. As an option, you can connect a USB flash drive via the USB host port to store your waveform and configuration setup from the instrument.
Built-in multi-lingual Quick Help menu provides instant assistance
Need assistance while operating the instrument? The built-in multi-lingual Quick Help menu helps to minimize downtime in the event that you need help to set up scope and DMM functions. The supported languages include English, German, Italian, Spanish, Portuguese, French, Korean, Traditional Chinese, Simplified Chinese and Japanese.
Figure 3 The U1600A series comes equipped with DWM features, allowing you to perform spectrum analysis and evaluate signal addition and subtraction from multiple channels.
Figure 4 The U1600A series comes with a PC Link application software that caters for data gathering, storage and documentation needs via USB full speed remote control from PC.
4
Oscilloscope Mode
The U1600A series handheld digital oscilloscopes offers the following standard and advanced features to make your analysis and troubleshooting tasks easier and faster.
Deep memory
The U1600A series comes standard w ith 125 kilobytes of memory depth, nearly 250 times the memory depth of competitive handheld digital oscilloscope in this class.
Autoscale
Autoscale enables the instrument to quickly display any active signals, and automatically adjust the vertical and horizontal settings with trigger control for the best signal display.
Dual Waveform Math (DWM) and Fast Fourier Transform (FFT)
The U1600A series offers analysis functions including addition and subtraction for DWM, as well as FFT with four windowing techniques (Rectangular, Hanning, Hamming and Blackman­Harris). FFT functions is only available for the U1604A model.
Cursor measurement
Use cursor function to manually or automatically place readout of the waveform’s voltage at any desired vertical or horizontal point.
22 automatic measurements
Up to 22 automatic available measurements. You can make and display four different measurements simultaneously.
Advanced triggering
Advanced triggering includes edge, pulse width, pattern and video to help you isolate the signal you want to see.
Easy connectivity
The PC Link application software is bundled with the purchase of any U1600A series handheld digital oscilloscope. This software provides flexibility for data gathering, storage and documentation needs via USB connectivity. USB flash drive is also available to you as an option to save and retrieve configuration setups or waveforms to and from the USB flash drive.
Save and recall waveform and setup memories
Up to 10 waveforms and configuration setups can be stored and recalled at anytime for future use and reference.
Logger mode
The U1600A series allows you to customize your data logging for any DMM measurement. This sophiscated function allows you to record and consolidate a sequence of data points for data plotting purposes.
Digital Multimeter (DMM) Mode
Auto-range
All meter measurements come in auto-range mode – instrument will auto-select the most appropriate range for measurement.
Voltmeter
Voltmeter measurement includes DC voltage, AC voltage and AC+DC voltage with auto ­measurement of minimum, maximum and average value.
Ohmmeter
Ohmmeter measurement consists of resistance, capacitance , diode test and continuity test. The auto­measurement of minimum, maximum and average value applies only to resistance and continuity test.
Auxiliary meter
Auxiliary meter in volves temperature, ampere, humidity and pressure measurements. Similary, the auto ­measurement of minimum, maximum and average value is also available in this mode.
The U1600A Series Features
5
Vertical System : Scope Channels
Bandwidth (–3 dB) U1602A : DC to 20 MHz
U1604A : DC to 40 MHz
DC vertical gain accuracy 5 mV/div: ± 4% full scale
10 mV/div to 100 V/div: ± 3% full scale
Scope Channel Triggering
Trigger sensitivity DC to 50 MHz: 0.5 divisions
U1602A: 5 MHz to 20 MHz — 1 division U1604A: 5 MHz to 40 MHz — 1 division
[1] All specifications are warranted. Specifications are valid after a 30 minutes warm-up period and within ± 10 oC from firmware
calibration temperature.
[2] All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30 minutes warm-up
period and within ± 10
o
C from firmware calibration temperature.
SCOPE SPECIFICATIONS
[1]
SCOPE CHARACTERISTICS
[2]
Acquisition : Scope Channels
Maximum sampe rate U1602A : 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 125 ns/div)
U1604A : 200 MSa/s interleaved, 100 MSa/s each channel (50 s/div to 250 ns/div)
Equivalent sample rate U1604A : 2.5 GSa/s (125 ns/div to 10 ns/div)
Vertical resolution 8 bits
Maximum memory depth 125 kilobytes/channel
Peak detection 5 ns
Average Selectable in average number of 2, 4, 8, 16, 32, 64, 128, 256
Vertical System : Scope Channels
Analog channels Channel 1 and Channel 2 simultaneous acquisition
Bandwidth (–3 dB) U1602A : DC to 20 MHz
U1604A : DC to 40 MHz
AC coupled < 10 Hz without probe
Rise time U1602A : < 17 ns
U1604A : < 8 ns
Single shot bandwidth U1602A : 20 MHz
U1604A : 40 MHz
Vertical sensitivity 5 mV/div to 100 V/div (1:1 scope probe)
50 mV/div to 1 kV/div (10:1 scope probe) 500 mV/div to 10 kV/div (100:1 scope probe)
Maximum input CAT III 300 Vrms
Offset/Dynamic range ± 5 div
Input impedance
1 M
W || < 20 pF
Coupling AC, DC, GND
Probes U1560-60001 : 500 MHz 1:1 passive probe
U1561-60001 : 500 MHz 10:1 passive probe
Probe attenuation factors 1x, 10x, 100x
Coupling 3 Vp-p, ~ 1 kHz
Maximum probe input 1x CAT III 300 VAC
10x, 100x CAT III 600 VAC
Noise peak-to-peak 3% of full scale or 5 mV, whichever is greater
DC vertical offset accuracy ±0.1 div ±2 mV ±0.5% offset value
Single cursor accuracy 4% full scale
Dual cursor accuracy 4% full scale
6
Horizontal System
Range U1602A : 50 ns to 50 s/div
U1604A : 10 ns to 50 s/div
Resolution U1602A : 2 ns
U1604A : 400 ps
Reference position Left, center, right
Delay range (pre-trigger) 15 divisions
Delay range (post-trigger) 1000 divisions
Analog Dt accuracy
± 3%
Modes Main, XY, Roll
RMS Jitter 2% of horizontal scale or 5 ns whichever is higher
Trigger System
Source Channel 1 and Channel 2
Modes Auto, normal, single
Selections Edge, pulse width, pattern, video
Edge Trigger on a rising or falling edge of any source.
Pattern Trigger at the beginning of a pattern of high, low levels and rising or falling edge established
conditions of AND, OR, NOR and NAND between the channels.
Pulse width 200 ns to 10 s. Trigger when a positive or negative pulse width of any source larger than, less
than, equal to or not equal to duration.
Video Video trigger sensitivity : 0.7 division trigger level.
Available to both Channel 1 and Channel 2. Analog progressive and interlaced video standards including NTSC, PAL and SECAM. Positive or negative sync pulse polarity. Modes — all fields, even fields, odd fields or any line within a field.
Range ± 4 divisions from center screen
Level accuracy ± 0.4 divisions
Trigger sensitivity DC to 5 MHz : 0.5 divisions
U1602A : 5 MHz to 20 MHz — 1 division U1604A : 5 MHz to 40 MHz — 1 division
Coupling DC, AC (< 1 Hz), HF reject (> 50 kHz), LF reject (<30 kHz), Noise reject
Measurement System
Autoscale Finds and displays all active scope channels, sets edge trigger mode on highest numbered
channel, sets vertical sensitivity on scope channel. Requires voltage > 20 mVp-p, 0.5% duty cycle and frequency > 100 Hz.
Automatic measurement Measurements continuously updated.
Voltage Peak-to-peak, maximum, minimum, amplitude, top, base, +overshoot, –overshoot, preshoot,
RMS, mean and one cycle mean.
Time Frequency, period, +width, –width and +duty cycle and –duty cycle on any channel.
Rise time, fall time, delay and phase shift.
Cursors
Manually place readout of horizontal (X
, DX) and vertical (Y, DY).
Waveform math CH1 + CH2, CH1 – CH2, CH2 – CH1
FFT
[1]
Window Rectangular, Hamming, Hanning, Blackman-Harris
Amplitude Display Selectable in amplitude display of 1 dB, 2 dB, 5 dB, 10 dB
[1] FFT function is only available for U1604A model.
7
Function Range
Frequency, Test Current or
1 year Tcal ± 5oC
Burden Voltage
DC Voltage 600.0 mV 0.3 + 0.08
6.000 V
0.3 + 0.08
60.00 V
0.3 + 0.08
600.0 V 0.3 + 0.08
AC Voltage 600.0 mV – 600.0 V 50 Hz – 1 kHz 0.75 + 0.2
1 kHz – 30 kHz 3.0 + 0.2
AC + DC Voltage 6.0000 V – 600.0 V 50 Hz – 1 kHz 0.75 + 0.2
1 kHz – 30 kHz 3.0 + 0.2
Resistance
600.0 W
0.5 + 0.2
6.000 kW
0.5 + 0.2
60.00 kW
0.5 + 0.2
600.0 kW
0.5 + 0.2
6.000 MW
0.5 + 0.2
60.00 MW
1.0 + 0.2
Capacitance 60.00 nF 2.0 + 0.2
600.0 nF 2.0 + 0.2 6000 nF 2.0 + 0.2
60.00 µF
2.0 + 0.2
300.0 µF
2.0 + 0.2
Diode 1.000 V 0.5 mA 2.0 + 0.08
DIGITAL MULTIMETER SPECIFICATIONS
[1]
± (% of reading + % of range)
Measurement Characteristics
Full scale reading 6000 count
DC voltage, True RMS AC Voltage Maximum input voltage, 600 Vrms CAT II, 300 Vrms CAT III
DC coupled input coupling
Continuity
Beeper < 60
W in 600 W range
Source Digital multimeter measurements
Range 10 divisions
Record size 250 points
Time span Auto range 150 seconds to 20 days
Time reference Time from start
Record method Selectable minimum, maximum and average
DATA LOGGER
Display System
Display 4.5-inch diagonal color CSTN LCD
Resolution 320 x 240 pixels
Control Contrast control, infinite persistence on/off
Build-in help system Functional help displayed by pressing help button
Real time clock Time and date (user adjustable)
[1] For temperature between 0 oC to 18 oC and 28 oC to 50 oC , add 0.1x of reading + 0.02% of range for every degree Celsius
.
Storage
Save/Recall (non-volatile) Up to 10 setups and traces
8
Power Adapter
Line voltage range 50/60 Hz, 100 – 240 VAC Output voltage 12 VDC
Battery
Ni-MH rechargeable battery pack 7.2 V / 4500 mAH Operating time : 4 hours Charging time : 4.5 hours, measurement unit off Allow ambient temperature during charging : 10 oC to 40 oC
Operating Environment
Temperature Operating full accuracy 0oC to 50 oC
Non-operating –20 oC to 70 oC Humidity Operating full accuracy 80% RH at 40 oC Altitude Operating Up to 2000 m
Non-operating 15000 m (50000 ft)
ESD tolerance ± 4 kV
Safety Compliance
IEC 61010-1:2001/EN61010-1:2001 CSA C22.2 No. 61010-1:2004 UL 61010-1:2005 Pollution degree 2 This instrument is rated for indoor use only.
Dimension (HxWxD)
13.8 cm width x 24.1 cm x 6.6 cm depth
Weight
1.5 kg
I/O
USB 1.1 host and client. Firmware upgrade through USB.
Warranty
1 year + 2 years extended (optional)
GENERAL CHARACTERISTICS
Accessories included:
• Scope probe (1:1) CAT III 300 V
• Scope probe (10:1) CAT III 600 V
• Ground alligator clip
• DMM test lead
• Hook Clip
• Medium jaw alligator clip
• USB cable
• Power cord and AC adapter
• Ni-MH battery pack 4500 mA
• Quick Start Guide
• Product Reference CD-ROM containing User’s and Service Guide, Quick Start Guide and PC Link Application Software
• Certificate of Calibration (CoC)
• Test Report
Optional Accessories:
• Soft casing
• Scope probe (100:1) CAT III 600 V with ground
alligator clip
DIMENSIONS
Agilent Optional Accessories
Soft casing
Scope probe (100:1) CAT III 600 V with ground alligator clip
Agilent Technologies’ Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.”
Our Promise
Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
www.agilent.com
For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:
www.agilent.com/find/contactus
Phone or Fax
United States:
(tel) 800 829 4444 (fax) 800 829 4433
Canada:
(tel) 877 894 4414 (fax) 800 746 4866
China:
(tel) 800 810 0189 (fax) 800 820 2816
Europe:
(tel) 31 20 547 2111
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (080) 769 0800 (fax) (080) 769 0900
Latin America:
(tel) (305) 269 7500
Taiwan: (tel) 0800 047 866 (fax) 0800 286 331
Other Asia Pacific Countries:
(tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 09/26/05
Product specifications and descriptions in this document subject to change without notice.
© Agilent Technologies, Inc. 2006 Printed in Malaysia, August 31, 2006 5989-5576EN
www.agilent.com/find/emailupdates
Get the latest information on the products and applications you select.
Agilent Email Updates
Agilent Direct
www.agilent.com/find/agilentdirect
Quickly choose and use your test equipment solutions with confidence.
Loading...