Agilent HPLC Quick reference

HPLC Injection Systems: Agilent 1100 Series Autosamplers and Agilent 220 Micro Plate Sampler
Quick reference
For detailed information refer to brochure 5968-9103E
January 2001
Application area
Features
Sample capacity
Agilent 1100 Series manual injector
Order: G1328A
The ideal solution for laboratories expanding to HPLC. This injector for low throughput sampling is designed for general HPLC users.
The Agilent 1100 Series manual injector with a long-life Rheodyne® 7-port sample injection valve is easy to use and maintain.
Rheodyne® is a US registered trademark of Rheodyne L.P.
Agilent 1100 Series standard autosampler and thermostatted version
Order: G1313A and G1327A
Designed for the reliability, safety, and ease of use needed in pharmaceutical routine tasks and quality control, as well as for environmental and food analyses.
• Reliable injections from
0.1µl to 100 µl
• Easy adaption for injection volumes up to 1500 µl for appli­cations ranging from micro­bore to semipreparative chromatography
• Low internal volume of 300 µl for the minimum contribution to a system’s total internal volume
• Overlapped injections for increased productivity
• 100 × 2-ml vials/standard tray,
• 40 × 2-ml vials/standard tray,
• 15 × 6-ml vials/half tray
• Microvials (100 or 300 µl) with sleeves
Agilent 1100 Series thermostatted micro autosampler
Order: G1387A
Designed to perform capillary LC, allows injection of sample volumes from nl to µl ranges.
• A micro Rheodyne® valve and the optimized design of the needle seat, loop and seat capillaries minimize dispersion
• A high-resolution metering device offers resolution ten times better than a standard autosampler
• Bypass operation enables low delay volume
• 100 × 2-ml vials/standard tray,
• Microvials (100 or 300 µl) with sleeves
Agilent 1100 Series well-plate autosampler and thermostatted version
Order: G1367A and G1368A
Adds maximum flexibility and fast injection cycles to your Agilent LC system. Whenever high sample throughput and speed of analysis are points to consider, this is the autosampler to choose.
• Increased sample injection speed for high sample throughput
• Overlapped injections for increased productivity
• Minimal delay volumes for rapid gradients and fast equili­bration when bypassing the autosampler after sample injection.
• Flexible and convenient sample handling with different types of sample containers. 384-well plates allows you to process up to 768 samples unattended.
• 2 well plates (96 and 384) plus 10 additional 2-ml vials
• 100 × 2-ml vials/standard tray
• 40 × 2-ml vials/half tray
• Microvials with sleeves
Agilent 1100 Series micro well-plate autosampler and thermostatted version
Order: G1377A and G1378A
Designed to perform capillary LC, allows injection of sample volumes from nl to µl ranges.
• Increased sample injection speed for high sample throughput
• Flexible and convenient sample handling with different types of sample containers. 384-well plates allows you to process up to 768 samples unattended.
Additionally the sampler offers all features of G1387A.
• 2 well plates (96 and 384) plus 10 additional 2-ml vials
• 100 × 2-ml vials/standard
tray
Agilent 220 micro plate sampler
Order: G2250A
Highest sample capacity, which increases sample throughput and shortens response time. This is especially useful for drug discovery, combinatorial chemistry, medicinal chemistry and natural products analysis.
• The flexibility of sampling and fraction collection from the same device. This gives you a versatile tool to support screening, analysis and research.
• Fast cycle times, including a flow injection analysis (FIA) mode where a well can be analyzed every 30 seconds.
• Unattended high throughput with the ability to store and inject over 4,600 samples (using 384-well plates).
• 12 standard well plates including: 96-well plates, 96-deep-well plates, 384-well plates, PCR, tubes, 2-ml vials, test tubes, and sealed and unsealed vials
Thermostatting capacity
www.agilent.com/chem
Peltier temperature control from 4 to 40 °C for up to 100 2-ml vials containing thermally-labile samples
Peltier temperature control from 4 to 40 °C for up to 100 2-ml vials containing thermally-labile samples
Peltier temperature control from 4 to 40 °C for well plates and 2-ml vials containing thermally-labile samples
Peltier temperature control from 4 to 40 °C for well plates and 2-ml vials containing thermally-labile samples
Copyright © 2001 Agilent Technologies Printed in Germany, January 1, 2001 Publication Number 5988-1804EN
Loading...