Agilent EN12916:2006 DATA SHEET

SAFETY DATA SHEET
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Product name
:
1.1 Product identifier
1.3 Details of the supplier of the safety data sheet
e-mail address of person responsible for this SDS
:
pdl-msds_author@agilent.com
1.2 Relevant identified uses of the substance or mixture and uses advised against
Part no.
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
5190-0485-1
EN12916:2006 IP391-07 Sys. Cal. Std. 2
5190-0485-2
1.4 Emergency telephone number
Emergency telephone number (with hours of operation)
:
CHEMTREC®: +(44)-870-8200418
Agilent Technologies Manufacturing GmbH & Co. KG Hewlett-Packard-Str. 8 76337 Waldbronn Germany 0800 603 1000
Part no. (chemical kit)
:
5190-0485
Reagents and Standards for Analytical Chemistry Laboratory Use
EN12916:2006 IP391-07 Sys. Cal. Std. 1
1 x 1 ml
EN12916:2006 IP391-07 Sys. Cal. Std. 2
1 x 1 ml
Material uses
:
SECTION 2: Hazards identification
Classification according to Regulation (EC) No. 1272/2008 [CLP/GHS]
2.1 Classification of the substance or mixture
Product definition
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Mixture
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Mixture
EN12916:2006 IP391-07 Sys. Cal. Std. 1
H225
FLAMMABLE LIQUIDS
Category 2
H315
SKIN CORROSION/IRRITATION
Category 2
H336
SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE (Narcotic effects)
Category 3
H304
ASPIRATION HAZARD
Category 1
H400
SHORT-TERM (ACUTE) AQUATIC HAZARD
Category 1
H410
LONG-TERM (CHRONIC) AQUATIC HAZARD
Category 1
EN12916:2006 IP391-07 Sys. Cal. Std. 2
H225
FLAMMABLE LIQUIDS
Category 2
H315
SKIN CORROSION/IRRITATION
Category 2
H336
SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE Category 3
Date of issue/Date of revision
:
1/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 2: Hazards identification
See Section 11 for more detailed information on health effects and symptoms.
See Section 16 for the full text of the H statements declared above.
2.2 Label elements
Hazard pictograms
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Signal word
:
Hazard statements
:
Prevention
:
Precautionary statements
Response
:
Storage
:
Disposal
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Danger
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Danger
EN12916:2006 IP391-07 Sys. Cal. Std. 1
H225 - Highly flammable liquid and vapour.
H304 - May be fatal if swallowed and enters airways.
H315 - Causes skin irritation.
H336 - May cause drowsiness or dizziness.
H410 - Very toxic to aquatic life with long lasting effects.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
H225 - Highly flammable liquid and vapour.
H304 - May be fatal if swallowed and enters airways.
H315 - Causes skin irritation.
H336 - May cause drowsiness or dizziness.
H410 - Very toxic to aquatic life with long lasting effects.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P273 - Avoid release to the environment.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P273 - Avoid release to the environment.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
P391 - Collect spillage.
P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
P391 - Collect spillage.
P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
P403 + P233 - Store in a well-ventilated place. Keep container tightly closed.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
P403 + P233 - Store in a well-ventilated place. Keep container tightly closed.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
(Narcotic effects)
H304
ASPIRATION HAZARD
Category 1
H400
SHORT-TERM (ACUTE) AQUATIC HAZARD
Category 1
H410
LONG-TERM (CHRONIC) AQUATIC HAZARD
Category 1
Date of issue/Date of revision
:
2/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 2: Hazards identification
:
Other hazards which do not result in classification
EN12916:2006 IP391-07 Sys. Cal. Std. 1
None known.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
None known.
Supplemental label elements
Tactile warning of danger
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Not applicable.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Not applicable.
:
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Not applicable.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Not applicable.
Special packaging requirements
Hazardous ingredients
:
2.3 Other hazards
Annex XVII - Restrictions on the manufacture, placing on the market and use of certain dangerous substances, mixtures and articles
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Not applicable.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Not applicable.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
- heptane
EN12916:2006 IP391-07 Sys. Cal. Std. 2
- heptane
Product meets the criteria for PBT or vPvB according to Regulation (EC) No. 1907/2006, Annex XIII
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
This mixture does not contain any substances that are assessed to be a PBT or a vPvB.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
This mixture does not contain any substances that are assessed to be a PBT or a vPvB.
SECTION 3: Composition/information on ingredients
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Mixture
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Mixture
:
3.1 Substances
Product/ingredient name
EN12916:2006 IP391-07 Sys. Cal. Std. 1
n-Heptane
EC: 205-563-8 CAS: 142-82-5 Index: 601-008-00-2
≥90
Flam. Liq. 2, H225 Skin Irrit. 2, H315 STOT SE 3, H336 Asp. Tox. 1, H304 Aquatic Acute 1, H400 (M=1) Aquatic Chronic 1, H410 (M=1)
[1] [2]
Cyclohexane
EC: 203-806-2 CAS: 110-82-7 Index: 601-017-00-1
≤3
Flam. Liq. 2, H225 Skin Irrit. 2, H315 STOT SE 3, H336 Asp. Tox. 1, H304 Aquatic Acute 1, H400 (M=1) Aquatic Chronic 1, H410 (M=1)
[1] [2]
naphthalene
EC: 202-049-5 CAS: 91-20-3 Index: 601-052-00-2
≤0.3
Acute Tox. 4, H302 Carc. 2, H351 Aquatic Acute 1, H400 (M=1) Aquatic Chronic 1, H410 (M=1)
[1] [2]
EN12916:2006 IP391-07 Sys. Cal.
Identifiers
%
Type
Regulation (EC) No. 1272/2008
[CLP]
Date of issue/Date of revision
:
3/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 3: Composition/information on ingredients
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
[1] Substance classified with a health or environmental hazard [2] Substance with a workplace exposure limit [3] Substance meets the criteria for PBT according to Regulation (EC) No. 1907/2006, Annex XIII [4] Substance meets the criteria for vPvB according to Regulation (EC) No. 1907/2006, Annex XIII [5] Substance of equivalent concern [6] Additional disclosure due to company policy
Type
Std. 2
n-Heptane
EC: 205-563-8 CAS: 142-82-5 Index: 601-008-00-2
≥90
Flam. Liq. 2, H225 Skin Irrit. 2, H315 STOT SE 3, H336 Asp. Tox. 1, H304 Aquatic Acute 1, H400 (M=1) Aquatic Chronic 1, H410 (M=1)
[1] [2]
See Section 16 for the full text of the H statements declared above.
SECTION 4: First aid measures
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
4.1 Description of first aid measures
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to­mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to­mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Inhalation
Eye contact
:
:
Date of issue/Date of revision
:
4/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 4: First aid measures
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Aspiration hazard if swallowed. Can enter lungs and cause damage. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Aspiration hazard if swallowed. Can enter lungs and cause damage. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Skin contact
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Ingestion
:
:
Protection of first-aiders
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
No action shall be taken involving any personal risk or without suitable training. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
No action shall be taken involving any personal risk or without suitable training. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.
4.2 Most important symptoms and effects, both acute and delayed
Potential acute health effects
Inhalation
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
No known significant effects or critical hazards.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
No known significant effects or critical hazards.
:
Eye contact
Date of issue/Date of revision
:
5/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 4: First aid measures
Notes to physician
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
:
Specific treatments
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Can cause central nervous system (CNS) depression. May be fatal if swallowed and enters airways.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Can cause central nervous system (CNS) depression. May be fatal if swallowed and enters airways.
:
Ingestion
Skin contact
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Causes skin irritation.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Causes skin irritation.
Over-exposure signs/symptoms
Skin contact
Ingestion
Inhalation
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Adverse symptoms may include the following:
nausea or vomiting
headache
drowsiness/fatigue
dizziness/vertigo
unconsciousness
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Adverse symptoms may include the following:
nausea or vomiting
headache
drowsiness/fatigue
dizziness/vertigo
unconsciousness
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Adverse symptoms may include the following:
nausea or vomiting
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Adverse symptoms may include the following:
nausea or vomiting
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Adverse symptoms may include the following:
irritation
redness
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Adverse symptoms may include the following:
irritation
redness
:
:
:
Eye contact
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Adverse symptoms may include the following:
pain or irritation
watering
redness
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Adverse symptoms may include the following:
pain or irritation
watering
redness
4.3 Indication of any immediate medical attention and special treatment needed
EN12916:2006 IP391-07 Sys. Cal. Std. 1
No specific treatment.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
No specific treatment.
:
Date of issue/Date of revision
:
6/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 5: Firefighting measures
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Hazardous combustion products
Hazards from the substance or mixture
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Highly flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapour/gas is heavier than air and will spread along the ground. Vapours may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. This material is very toxic to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Highly flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapour/gas is heavier than air and will spread along the ground. Vapours may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. This material is very toxic to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Use dry chemical,
CO₂,
water spray (fog) or foam.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Use dry chemical,
CO₂,
water spray (fog) or foam.
5.1 Extinguishing media
:
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Do not use water jet.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Do not use water jet.
Suitable extinguishing media
:
Unsuitable extinguishing media
:
5.2 Special hazards arising from the substance or mixture
5.3 Advice for firefighters
Special precautions for fire-fighters
:
Date of issue/Date of revision
:
7/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
EN12916:2006 IP391-07 Sys. Cal. Std. 1,2, Part Number 5190-0485
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2015/830 - United Kingdom (UK)
SECTION 5: Firefighting measures
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Special protective equipment for fire­fighters
:
SECTION 6: Accidental release measures
6.2 Environmental precautions
EN12916:2006 IP391-07 Sys. Cal. Std. 1
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities. Collect spillage.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities. Collect spillage.
6.3 Methods and material for containment and cleaning up
6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency personnel
:
For emergency responders
:
EN12916:2006 IP391-07 Sys. Cal. Std. 1
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
EN12916:2006 IP391-07 Sys. Cal. Std. 2
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
EN12916:2006 IP391-07 Sys. Cal. Std. 1
If specialised clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non­emergency personnel".
EN12916:2006 IP391-07 Sys. Cal. Std. 2
If specialised clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non­emergency personnel".
:
Date of issue/Date of revision
:
8/24
28/01/2021
Date of previous issue
:
21/05/2018
Version
:
3
Loading...