The information contained in this document is subject to change without notice.
Hewlett-Packard makes no warranty of any kind with regard to this material, including
but not limited to, the implied warranties of merchantability and fitness for a particular
purpose. Hewlett-Packardshallnot be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of this
material.
Hewlett-Packard Company certifies that this product met its published specifications at
the time of shipment from the factory. Hewlett-Packard further certifies that its
calibration measurements are traceable to the United States National Institute of
Standards and Technology, to the extent allowed by the Institute's calibration facility, and
to the calibration facilities of other International Standards Organization members.
Regulatory and Warranty Information
The regulatory and warranty information is in the User's Guide.
Assistance
Product maintenance agreements and other customer assistance agreements are available
for Hewlett-Packard products. For any assistance, contact your nearest Hewlett-Packard
sales or service office. See Table 2-1 on page 2-26 for the nearest office.
Safety Notes
The following safety notes are used throughout this manual. Familiarize yourself with
each of the notes and its meaning before operating this instrument.
WARNINGWarning denotes a hazard. It calls attention to a procedure which, if
not correctly performed or adhered to, could result in injury or loss
of life. Do not proceed beyond a warning note until the indicated
conditions are fully understood and met.
CAUTIONCaution denotes a hazard. It calls attention to a procedure that, if not
correctly performed or adhered to, would result in damage to or destruction of
the instrument. Do not proceed beyond a caution sign until the indicated
conditions are fully understood and met.
iii
General Safety Considerations
SOFTKEY
WARNINGFor continued protection against fire hazard replace line fuse only
with same type and rating (3A/250V). The use of other fuses or
material is prohibited.
WARNINGThis is a Safety Class I product (provided with a protective earthing
ground incorporated in the power cord). The mains plug shall only
be inserted in a socket outlet provided with a protective earth
contact. Any interruption of the protective conductor, inside or
outside the instrument, is likely to make the instrument dangerous.
Intentional interruption is prohibited.
CAUTIONVentilation Requirements: When installing the instrument in a cabinet,
the convection into and out of the instrument must not be restricted. The
ambient temperature (outside the cabinet) must be less than the maximum
operating temperature of the instrument by 4 °C for every 100 watts
dissipated in the cabinet. If the total power dissipated in the cabinet is
greater than 800 watts, then forced convection must be used.
How to Use This Guide
This guide uses the following conventions:
Front-Panel Key
Screen TextThis represents text displayed on the instrument’s screen.
iv
This represents a key physically located on the
instrument.
This represents a “softkey,” a key whose label is
determined by the instrument’s firmware.
Documentation Map
The Installation and Quick Start Guide provides procedures for
installing, configuring, and verifying the operation of the analyzer. It
also will help you familiarize yourself with the basic operation of the
analyzer.
The User’s Guide shows how to make measurements, explains
commonly-used features, and tells you how to get the most
performance from your analyzer.
The Reference Guide provides reference information, such as
specifications, menu maps, and key definitions.
The Programmer’s Guide provides general HP-IB programming
information, a command reference, and example programs. The
Programmer’s Guide contains a CD-ROM with example programs.
The CD-ROM provides the Installation and Quick Start Guide, the
User’s Guide, the Reference Guide, and the Programmer’s Guide in
PDF format for viewing or printing from a PC.
The Service Guide provides information on calibrating,
troubleshooting,and servicing your analyzer. The Service Guide is not
part of a standard shipment and is available only as Option 0BW, or
by ordering HP part number 08720-90397. A CD-ROM with the
Service Guide in PDF format is included for viewing or printing from
a PC.
country
5062-39788Rack Flange Kit (Option 1CM only)
5062-40728Rack Flange Kit with Handles (Option 1CP only)
5062-39908Front Handle Kit (standard)
6EEPROM Backup Disk
7AC power cable
Description
1-4Chapter1
Installing Your Analyzer
STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels
STEP 2. Familiarize Yourself with the Analyzer Front and
Rear Panels
Analyzer Front Panel
CAUTIONDo not mistake the line switch for the disk eject button. See the figure below. If the
line switch is mistakenly pushed, the instrument will be turned off, losing all settings
and data that have not been saved.
1 LINE (power on/off) switch8 RESPONSE function block
2 Display9 ACTIVE CHANNEL keys
3 Disk drive10 ENTRY block
4 Disk eject button11 INSTRUMENT STATE function block
5 Softkeys
6 key
Return
7 STIMULUS function block14 ES models only:
Chapter 11-5
12 key
Preset
13 ES models only: R CHANNEL connectors
ET models only:
PORT 1
and
PORT 2
REFLECTION
and
TRANSMISSION
Installing Your Analyzer
STEP 2. Familiarize Yourself with the Analyzer Front and Rear Panels
(mini-DIN)14 TEST SEQUENCE
5 Power cord receptacle,
with fuse15 LIMIT TEST
6 Line voltage selector switch16 MEASURE RESTART
7 Fan17 TEST SET I/O INTERCONNECT
8 10 MHZ PRECISION
REFERENCE OUTPUT
a
18 BIAS INPUTS AND FUSES
9 10 MHZ REFERENCE
ADJUST
a
19 Serial number plate
10 EXTERNAL REFERENCE
INPUT connector20 RF IN/OUT
b
21 EXTERNAL MONITOR: VGA
a. Option 1D5 only.
b. Option 085 only.
1-6Chapter1
Installing Your Analyzer
STEP 3. Meet Electrical and Environmental Requirements
STEP 3. Meet Electrical and Environmental Requirements
1. Set the line-voltage selector to the
position that corresponds to the AC power
source.
3. Ensure the operating environment meets
the following requirements:
2. Ensure the available AC power source
meets the following requirements:
• 90–132 VAC
• 47–66 Hz / 400 Hz (single phase)
OR
• 198–265 VAC
• 47–66 Hz (single phase)
The analyzer power consumption is 350 VA
maximum.
4. Verify that the power cable is not
damaged, and that the power-source outlet
provides a protective earth contact.
• 0 to 55 °C
• < 95% relative humidity at 40 °C
(non-condensing)
• < 15,000 feet (≈ 4,500 meters) altitude
Some analyzer performance parameters are
specified for 25 °C ±5 °C. Refer to the
Reference Guide for information on the
environmental compatibility of warranted
performance.
WARNING: Any interruption of the
protective (grounding) conductor or
disconnection of the protective earth
terminal, can result in personal injury,
or may damage the analyzer.
Chapter 11-7
Installing Your Analyzer
STEP 3. Meet Electrical and Environmental Requirements
5. Ensure there are at least six inches of clearance between the sides and back of either the
stand-alone analyzer or the system cabinet.
CAUTION: The environmental temperature must be 4 °C less than the maximum
operating temperature of the analyzer for every 100 watts dissipated in the cabinet. If the
total power dissipated in the cabinet is >800 watts, then you must provide forced
convection.
6. Set up a static-safe workstation. Electrostatic discharge (ESD) can damage or destroy
electronic components.
• static-control table mat and earth
ground wire: HP part number 9300-0797
• wrist-strap cord: HP part number
9300-0980
• wrist-strap: HP part number 9300-1367
• heel-straps: HP part number 9300-1308
• floor mat: not available through
Hewlett-Packard
1-8Chapter1
STEP 4. Configure the Analyzer
STEP 4. Configure the Analyzer
This step shows you how to set up your particular analyzer configuration.
• standard configuration
• Option 1D5 configuration − high stability frequency reference
• printer or plotter configuration
• rack-mount configuration
Installing Your Analyzer
Chapter 11-9
Installing Your Analyzer
STEP 4. Configure the Analyzer
To Configure the Standard Analyzer
Connect test port cables and optional adapters if you are using other connector types.
To Configure an Analyzer with a High Stability Frequency
Reference (Option 1D5)
Connect the jumper cable on the analyzer rear panel as shown.
1-10Chapter1
STEP 4. Configure the Analyzer
PARALLEL
COPY
GPIO
COPY
GPIO
To Configure the Analyzer with Printers or Plotters
1. Connect your printer or plotter to the corresponding interface.
Installing Your Analyzer
2. If you are using the parallel interface, pressand toggleuntil your
choice of or appears.
Local
If you choose, the parallel port is
dedicated for normal copy device use
(printers or plotters).
If you choose, the parallel port is
dedicated for general purpose I/O. The
analyzer controls the data input or output
through the sequencing capability of the
analyzer.
Chapter 11-11
Installing Your Analyzer
SET ADDRESSES
PRINTER PORT
PLOTTER PORT
SET ADDRESSES
PLOTTER PORT
DISK
HPIB
PARALLEL
SERIAL
PLOTTER PORT
PRINTER PORT
HPIB
PARALLEL [COPY]
PARALLEL
STEP 4. Configure the Analyzer
3. Press and then choose either or
, depending on your hardcopy device. Or, if you are plotting your files
to disk, press.
4. Press the key that corresponds to your printer or plotter interface:,
(parallel port), or (serial port). NOTE: The plotter menu is
shown as an example. It will only appear if you select. Similar
interface choices will appear if you select.
• If you select, the HP-IB address
selection is active. Enter the HP-IB
address of your printer or plotter,
followed by.
• If you have already selected the
parallel-port configuration, you must
also selectinthis menu in
order to generate a hardcopy.
x1
choice for the
1-12Chapter1
Installing Your Analyzer
PLOTTER BAUD RATE
PRINTER BAUD RATE
PLOTTER PORT
XMIT CNTRL
Xon/Xoff
DTR/DSR
PRINTER PORT
Xon/Xoff
DTR/DSR
STEP 4. Configure the Analyzer
5. If you will be using the serial port, adjust the analyzer's baud rate until it is equal to the
baud rate set on the peripheral by pressing or
and theandfront panel keys. NOTE: The plotter
menu is shown as an example. It will only appear if you select.
You can set the analyzer to the following
baud rates:
• 1200
• 2400
• 4800
• 9600
• 19200
6. Also, if you will be using the serial port, you must toggle the transmission control
(handshaking protocol) until your choice of or
appears (equal to the transmission control set on the peripheral). The printer menu is
shown as an example. It will only appear if you select.
NOTE: Transmission control for plotters is set programmatically.
• sets transmission
on/transmission off (software
handshake).
• sets data terminal
ready/data set ready (hardware
handshake).
Chapter 11-13
Installing Your Analyzer
PLTR TYPE
PLOTTER
HPGL PRT
PLOTTER
HPGL PRT
PRNTR TYPE
THINKJET
DESKJET
LASERJET
PAINTJET
DJ 540
EPSON-P2
STEP 4. Configure the Analyzer
7. If you will be creating a plot of the data, toggle until your choice of
or appears.
• Choose for a pen plotter.
• Choose for a PCL5
compatible printer.
a
8. If you will be using a printer, toggle until your printer choicea appears.
• Choose your printer type from these HP
printers:
❏
❏
(except for HP DeskJet 540 and
Deskjet 850C)
❏
❏
❏ (for use with
HP DeskJet 540 and
Deskjet 850C—converts 100 dpi
raster information to 300 dpi raster
format)
• Choose for
Epson-compatible printers (ESC/P2
printer control language).
a. For a current printer compatibility guide, consult the web page at
http://www.hp.com/go/pcg.
1-14Chapter1
Installing Your Analyzer
SET CLOCK
ROUND SECONDS
STEP 4. Configure the Analyzer
9. Press to begin
setting and activating the time stamp
feature so the analyzer places the time and
date on your hardcopies and disk
directories.
11. Press when the
time is exactly as you have set it.
System
10. Press each of the following softkeys to
set the date and time, followed by.
x1
Chapter 11-15
Installing Your Analyzer
STEP 4. Configure the Analyzer
To Configure the Analyzer for Bench Top or Rack Mount Use
There are three kits available for the analyzer:
• instrument front handles kit (standard: HP part number 5062-3990)
• cabinet flange kit without front handles (Option 1CM: HP part number 5062-3978)
• cabinet flange kit with front handles (Option 1CP: HP part number 5062-4072)
1-16Chapter1
To Attach Front Handles to the Analyzer (Standard)
Installing Your Analyzer
STEP 4. Configure the Analyzer
1. Ensure that the front handle kit is complete.
NOTE: If any items are damaged or missing
from the kit, contact the nearest HP sales or
service office to order a replacement kit. Items
within the kit (handles, flanges, screws, etc.)
are not individually available.
• (2) front handles
• (6) screws
• (2) trim strips
2. Remove the side trim strips.
3. Attach the handles to the sides of the front
panel, using three screws for each handle.
4. Place the new trim strip over the screws on
the handles.
WARNING: If an instrument handle is
damaged, you should replace it
immediately. Damaged handles can break
while you are moving or lifting the
instrument and cause personal injury or
damage to the instrument.
Chapter 11-17
Installing Your Analyzer
STEP 4. Configure the Analyzer
To Attach Cabinet Flanges without Front Handles to the Analyzer
(Option 1CM)
1. Ensure that the cabinet flange kit is
complete.
• (2) cabinet mount flanges
• (6) screws
3. Attach the cabinet flanges to the sides of
the front panel using three screws for each
flange.
2. Remove side trim strips.
4. Remove the feet and the tilt stands before
cabinet mounting the instrument.
1-18Chapter1
STEP 4. Configure the Analyzer
To Attach Cabinet Flanges with Front Handles to the Analyzer
(Option 1CP)
Installing Your Analyzer
1. Ensure that the cabinet flange kit with
handles is complete.
• (2) cabinet mount flanges
• (2) front handles
• (6) screws
3. Attach the cabinet mount flanges and the
handles to the sides of the front panel, using
three screws per side. (Attach the flanges to
the outside of the handles.)
2. Remove the side trim strips.
4. Remove the feet and the tilt stands before
cabinet mounting the instrument.
WARNING: If an instrument handle is
damaged, you should replace it
immediately. Damaged handles can
break while you are moving or lifting
the instrument and cause personal
injury or damage to the instrument.
Chapter 11-19
Installing Your Analyzer
STEP 5. Verify the Analyzer Operation
STEP 5. Verify the Analyzer Operation
The following procedures show you how to check your analyzer for correct operation:
• viewing installed options
• initiating self-test
• running operator's check
• testing transmission mode
• testing reflection mode
NOTEIf the analyzer should fail any of the following tests, call the nearest HP sales
or service office to determine the type of warranty you have. If repair is
necessary, send the analyzer (and the EEPROM backup disk) to the nearest
HP service center with a description of any failed test and any error message.
Ship the analyzer using the original packaging materials. Returning the
analyzer in anything other than the original packaging may result in
non-warranted damage. A table listing of Hewlett-Packard sales and service
offices is provided in Table 2-1 on page 2-26.
NOTEThe illustrations depicting the analyzer display were made using an ES
model. Other analyzer displays may appear different, depending on model
and options.
1-20Chapter1
To View the Installed Options
SERVICE MENU
FIRMWARE REVISION
Installing Your Analyzer
STEP 5. Verify the Analyzer Operation
1. Cycle the AC power using the LINE switch, or press
.
2. Locate the serial number and configuration options. Compare them to the shipment
documents.
System
Chapter 11-21
Installing Your Analyzer
STEP 5. Verify the Analyzer Operation
To Initiate the Analyzer Self-Test
1. Cycle the AC power using the LINE switch.
2. Watch for the following indications that the analyzer is operating correctly:
1-22Chapter1
To Run the Operator's Check
SERVICE MENU
TESTS
EXTERNAL TESTS
EXECUTE TEST
CONTINUE
EXECUTE TEST
CONTINUE
EXECUTE TEST
CONTINUE
Installing Your Analyzer
STEP 5. Verify the Analyzer Operation
1. Connect the equipment as shown.
3. ET models only: Press
. Follow the prompts
shown on the analyzer display and then
press.
2. Press
Follow the prompts shown on the analyzer
display and then press.
3. ES models only: Press
shown on the analyzer display and then press
PresetSystem
.
. Follow the prompts
.
Chapter 11-23
Installing Your Analyzer
Trans: FWD S21(B/R)
TRANSMISSN
Trans: REV S12 (A/R)
STEP 5. Verify the Analyzer Operation
To Test the Transmission Mode
1. Connect the equipment as shown and
press.NOTE: The test port return
cable should have low-loss characteristics to
avoid a degradation in frequency response
at higher frequencies.
3. Look at the measurement trace displayed
on the analyzer. It should be similar to the
trace below.
PresetChan 2Meas
2. To check the forward transmission mode
for channel 2, press
or
.
4. ES models only: To check the reverse
transmission mode for channel 2, press
Meas
measurement trace should be similar to the
trace below.
. The
1-24Chapter1
To Test the Reflection Mode
Refl: REV S22 (B/R)
Installing Your Analyzer
STEP 5. Verify the Analyzer Operation
1. Connect the equipment as shown and
press.
3. ES models only: To check the reverse
reflection mode for channel 1, press
trace should be similar to the trace shown
below.
Preset
Meas
. The measurement
2. Look at the measurement trace displayed
on the analyzer. It should be similar to the
trace below.
4. If you are ready to start making
measurements, continue with the next
chapter, “Quick Start: Learning How to
Make Measurements.”
Chapter 11-25
Installing Your Analyzer
FILE UTILITIES
FORMAT DISK
FORMAT:LIF
FORMAT:DOS
FORMAT INT DISK
YES
SERVICE MENU
SERVICE MODES
MORE
STORE EEPR
SELECT DISK
INTERNAL DISK
RETURN
SAVE STATE
STEP 6. Back Up the EEPROM Disk
STEP 6. Back Up the EEPROM Disk
Description
Correction constants are stored in EEPROM on the A7 controller assembly. The advantage
of having an EEPROM backup disk is the ability to store all the correction-constant data to
a new or repaired A7 assembly without having to rerun the correction-constant
procedures. The analyzer is shipped from the factory with an EEPROM backup disk which
is unique to each instrument. It is prudent to make a copy of the EEPROM backup disk so
that it can be used in case of failure or damage to the original backup disk.
Equipment
3.5-inch disk.......................................................................................HP 92192A (box of 10)
CAUTIONDo not mistake the line switch for the disk eject button. If the line switch is
mistakenly pushed, the instrument will be turned off, losing all settings and
data that have not been saved.
EEPROM Backup Disk Procedure
1. Press.
2. Insert a 3.5-inch disk into the analyzer disk drive.
3. If the disk is not formatted, press.
• To format a LIF disk, select (The supplied EEPROM backup disk is
• To format a DOS disk, select.
Press and answer at the query.
4. Press. Toggle
to ON. Then press
NOTEA default file “FILE00” is created. The file name appears in the upper
Preset
Save/Recall
LIF. The analyzer does not support LIF-HFS format.)
System
Save/Recall
to store the correction-constants data onto floppy disk.
left-hand corner of the display. The file type “ISTATE(E)” describes the file as
an instrument-state with EEPROM backup.
1-26Chapter1
Installing Your Analyzer
FILE UTILITIES
RENAME FILE
ERASE TITLE
SELECT LETTER
DONE
STEP 6. Back Up the EEPROM Disk
5. Press. Use the front panel knob
and the softkey to rename the file “FILE00” to “N12345” where
12345 represents the last 5 digits of the instrument's serial number. (The first character
in the file name must be a letter.) When finished, press.
6. Label the disk with the serial number of the instrument, the date, and the words
“EEPROM Backup Disk.”
NOTEWhenever the analyzer is returned to Hewlett-Packard for servicing and/or
calibration, the EEPROM backup disk should be returned with the analyzer.
This will significantly reduce the instrument repair time.
7. The EEPROM backup disk procedure is now complete.
Chapter 11-27
Installing Your Analyzer
STEP 6. Back Up the EEPROM Disk
1-28Chapter1
2Quick Start: Learning How to Make
Measurements
2-1
Quick Start: Learning How to Make Measurements
Introduction
Introduction
The information and procedures in this chapter teach you how to make measurements and
what to do if you encounter a problem with your analyzer. The following sections are
included:
• Front Panel
• Measurement Procedure
• Learning to Make Transmission Measurements
• Learning to Make Reflection Measurements
• If You Encounter a Problem
NOTEThe illustrations depicting the analyzer display were made using an ES
model. Other analyzer displays may appear different, depending on model
and options.
2-2Chapter2
Quick Start: Learning How to Make Measurements
Analyzer Front Panel
Analyzer Front Panel
CAUTIONDo not mistake the line switch for the disk eject button. See the figure below.
If the line switch is mistakenly pushed, the instrument will be turned off,
losing all settings and data that have not been saved.
Figure 2-1 The Analyzer Front Panel
1. LINE switch. This switch controls AC power to the analyzer. 1 is on, 0 is off.
2. Display. This shows the measurement data traces, measurement annotation, and
softkey labels.
3. Disk drive. This 3.5-inch drive allows you to store and recall instrument states and
measurement results for later analysis.
4. Disk eject button. This button ejects the disk from the disk drive.
5. Softkeys. These keys provide access to menus that are shown on the display.
6.key. This key returns the previous softkey menu shown on the display.
Return
7. STIMULUS function block. The keys in this block allow you to control the analyzer
source's frequency, power, and other stimulus functions.
8. RESPONSE function block. The keys in this block allow you to control the
measurement and display functions of the active display channel.
9. ACTIVE CHANNEL keys. The analyzer has four independent display channels.
These keys allow you to select the active channel. Then any function you enter applies
Chapter 22-3
Quick Start: Learning How to Make Measurements
Analyzer Front Panel
to this active channel. Notice that the light next to the current active channel’s key is
illuminated.
10. The ENTRY block. This block includes the knob, the stepkeys, and the
number pad. These allow you to enter numerical data and control the markers.
You can use the numeric keypad to select digits, decimal points, and a minus sign for
numerical entries. You must also select a units terminator to complete value inputs.
11. INSTRUMENT STATE function block. These keys allow you to control
channel-independent system functions such as the following:
• copying, save/recall, and HP-IB controller mode
• limit testing
• tuned receiver mode
• frequency offset mode (Option 089)
• test sequence function
• time domain transform (Option 010)
HP-IB STATUS indicators are also included in this block.
12.key. This key returns the instrument to either a known factory preset state, or
Preset
a user preset state that can be defined. Refer to the “Preset State and Memory
Allocation” chapter in the Reference Guide for a complete listing of the instrument
preset condition.
13. R CHANNEL connectors. (ES models only) These connectors allow you to apply an
input signal to the analyzer's R channel, for frequency offset mode.
14. ES models only: PORT 1 and PORT 2. These ports output a signal from the source
and receive input signals from a device under test. PORT 1 allows you to measure S
12
and S11. PORT 2 allows you to measure S21 and S22.
ET models only: REFLECTION and TRANSMISSION. The REFLECTION port
allows you to make reflection measurements, outputting a signal from the source and
receiving input signals from a device under test. The TRANSMISSION port allows you
to make transmission measurements, receiving input signals from a device under test.
2-4Chapter2
Quick Start: Learning How to Make Measurements
Measurement Procedure
Measurement Procedure
This is a general measurement procedure that is used throughout the guide to illustrate
the use of the analyzer.
Step 1. Choose measurement parameters with your test device
connected
• Press the key to return the analyzer to a known state.
• Connect your device under test (DUT) to the analyzer.
CAUTIONDamage may result to the DUT if it is sensitive to the analyzer's default
• Choose the settings that are appropriate for the intended measurement.
❏ measurement type (S
❏ frequencies
❏ number of points
❏ power
❏ measurement trace format
• Make adjustments to the parameters while you are viewing the device response.
Preset
output power level. To avoid damaging a sensitive DUT, be sure to set the
analyzer's output power to an appropriate level before connecting the DUT to
the analyzer.
or reflection, for example)
11
Step 2. Make a measurement calibration
Press the key to begin to perform a measurement calibration using a known set of
standards (a calibration kit). Error-correction establishes a magnitude and phase
reference for the test setup and reduces systematic measurement errors.
Cal
Step 3. Measure the device
• Reconnect the device under test.
• Use the markers to identify various device response values if desired.
Step 4. Output measurement results
• Store the measurement file to a disk.
• Generate a hardcopy with a printer or plotter.
Chapter 22-5
Quick Start: Learning How to Make Measurements
Trans: FWD S21 (B/R)
TRANSMISSN
AUTO SCALE
AVERAGING FACTOR
AVERAGING
Learning to Make Transmission Measurements
Learning to Make Transmission Measurements
This example procedure shows you how to measure the transmission response of a
10.24 GHz bandpass filter. The measurement parameters listed are unique to this
particular test device.
For further measurement examples, refer to the “Making Measurements” chapter in the
User's Guide.
Step 1. Choose the measurement parameters with your test device
connected
1. Press the key to return the analyzer to a known state.
Preset
2. Connect your test device to the analyzer as shown in Figure 2-2. Use adapters where
appropriate.
CAUTIONDamage may result to the device under test if it is sensitive to the analyzer's
default output power level. To avoid damaging a sensitive DUT, be sure to set
the analyzer's output power to an appropriate level before connecting the
DUT to the analyzer.
Figure 2-2Device Connections for a Transmission Measurement
3. Choose the following measurement settings:
Meas
Center10.24G/n
Span5G/n
Scale Ref
Avg
2-6Chapter2
or
32x1
. Toggle to ON.
Quick Start: Learning How to Make Measurements
CALIBRATE MENU
RESPONSE
THRU
SELECT DISK
INTERNAL MEMORY
INTERNAL DISK
EXTERNAL DISK
Learning to Make Transmission Measurements
4. Look at the device response to determine if these are the parameters that you want for
your device measurement. For example, if the trace is noisy you may want to increase
the test port output power (which increases the analyzer input power), reduce the IF
bandwidth, or add averaging. Or, to better see an area of interest, you may want to
change the test frequencies.
Step 2. Perform a measurement calibration
1. Disconnect your test device from the analyzer.
2. Connect a “thru” between the measurement cables, as shown in Figure 2-3. Include all
the adapters that you will use in your device measurement.
If noise reduction techniques are needed for the measurement, the instrument's
settings (reduced IF BW, and /or averaging) should be selected prior to any
error-correction.
Figure 2-3 Connections for a “Thru” Calibration Standard
3. Press the following keys to make a transmission response calibration:
Cal
4. To save the error-correction (measurement calibration), press:
Save/Recall
5. Next, choose from the following options:
• Choose if you want to save the calibration results and
• Choose if you want to save the calibration results and
• Choose if you want to save the calibration results and
Chapter 22-7
instrument state to the analyzer's memory.
instrument state to the disk that is in the analyzer's internal disk drive.
instrument state to the disk that is in an (optional) external disk drive that is
configured to the analyzer.
Quick Start: Learning How to Make Measurements
RETURN
SAVE STATE
AUTO SCALE
Learning to Make Transmission Measurements
6. Pressto save the error-correction (measurement calibration).
NOTEExample procedures for all types of error-correction (measurement
calibrations) are located in the “Calibrating For Increased Measurement
Accuracy” chapter in the User's Guide. For information on the analyzer
operation during error-correction (measurement calibration), refer to the
“Operating Concepts” chapter in the User's Guide.
Step 3. Measure the device
Measuring Insertion Loss
1. Reconnect your test device as in Figure 2-2.
2. Reposition the measurement trace for the best view. This can be done by pressing
Scale Ref
position, or the scale/division.
and, if necessary, adjusting the reference level, reference
3. Press and turn the front panel knob to place the marker at a frequency of
Marker
interest. Read the device's insertion loss to 0.001 dB resolution as shown in Figure 2-4.
The analyzer shows the frequency of the marker location in the active entry area
(upper-left corner of display). The analyzer also shows the amplitude and frequency of
the marker location in the upper-right corner of the display.
Figure 2-4 Example Measurement of Insertion Loss
Step 4. Output measurement results
This example procedure shows how to output (store) measurement results to a disk.
2-8Chapter2
Quick Start: Learning How to Make Measurements
SELECT DISK
INTERNAL DISK
RETURN
DEFINE DISK-SAVE
DATA ARRAY
RAW ARRAY
FORMAT ARY
GRAPHICS
DATA ONLY
DATA ONLY
DATA ONLY
SAVE USING BINARY
SAVE USING ASCII
RETURN
SAVE STATE
Learning to Make Transmission Measurements
For more information on creating a hardcopy of the measurement results, refer to
the "Printing, Plotting, and Saving Measurement Results" chapter in the User's Guide.
CAUTIONDo not mistake the line switch for the disk eject button. If the line switch is
mistakenly pushed, the instrument will be turned off, losing all settings and
data that have not been saved.
1. Insert a DOS- or LIF-formatted disk into the analyzer disk drive. The analyzer does not
support LIF-HFS (hierarchy file system).
2. Press. Choose to save the
Save/Recall
measurement results to the analyzer's internal disk drive.
3. Press.
• Toggle to ON if you want to store the error-corrected data on disk
with the instrument state.
• Toggleto ON if you want to store the raw data (ratioed and averaged,
but no error-correction) on disk with the instrument state.
• Toggle to ON if you want to store the formatted data on disk with
the instrument state.
• Toggle to ON if you want to store user graphics on disk with the
instrument state.
• Toggle to ON if you want to only store the measurement data of the
device under test. The analyzer will not store the instrument state and
error-correction (measurement calibration). Therefore, the saved data cannot be
retrieved into the analyzer.
NOTEToggling to ON will override all of the other save options.
Because this type of data is only intended for computer manipulation, the file
contents of a save cannot be recalled and displayed on the
analyzer.
• Choose if you want to store data in a binary format.
• Choose if you want to store data in an ASCII format, to later
4. Press and the analyzer saves the file with a default title.
Chapter 22-9
read on a computer.
Quick Start: Learning How to Make Measurements
SEARCH: MAX
MKR ZERO
MKR ZERO∆ REF=
WIDTHS
Learning to Make Transmission Measurements
Measuring Other Transmission Characteristics
Using the analyzer marker functions, you can derive several important filter parameters
from the measurement trace that is shown on the analyzer display.
Measuring 3 dB Bandwidth.
The analyzer can calculate your test device bandwidth between two equal power levels. In
this example procedure, the analyzer calculates the −3 dB bandwidth relative to the center
frequency of the filter.
1. Press and turn the front panel knob to move the marker to the center
Marker
frequency position of the filter passband. An alternative method is to press
Marker Search
which should put you very close to the center of the
passband.
You can also position the marker by entering a frequency location: for example, press
10.24G/n
2. Press to zero the delta marker magnitude and frequency (this
Marker
.
sets the delta marker reference). The −3 dB points will be relative to this marker.
The softkey label changes to to show you that the delta
∆
reference point is the small ∆ symbol.
3. Press to enter the marker search mode.
Marker Search
4. Toggle to ON.
The analyzer calculates the −3 dB bandwidth, the center frequency and the Q (quality
factor) of the test device and lists the results in the upper-right corner of the display.
Markers 3 and 4 indicate the location of the −3 dB points, as shown in Figure 2-5.
Figure 2-5Example Measurement of 3 dB Bandwidth
2-10Chapter2
Quick Start: Learning How to Make Measurements
WIDTH VALUE
all OFF
MARKER 1
MKR ZERO
SEARCH: MIN
IF BW
AVERAGING
Learning to Make Transmission Measurements
5. Press and enter.
−6x1
The analyzer now calculates the bandwidth between −6 dB power levels.
6. Press when you are finished with this measurement.
Marker
Measuring Out-of-Band Rejection.
1. Press. The marker appears where you placed it during the bandwidth
measurement.
2. Press.
Marker Search
The marker automatically searches for the minimum point on the trace. The frequency
and amplitude of this point, relative to the delta symbol in the center of the filter
passband, appear in the upper-right corner of the display. This value is the difference
between the maximum power in the passband and the power in the rejection band, that
is, one of the peaks in the rejection band.
Figure 2-6Example Measurement of Out-of-Band Rejection
NOTEYou can use the marker search mode to search the trace for the maximum
point or for any target value. The target value can be an absolute level (for
example, −3 dBm) or a level relative to the location of the small delta symbol
(for example: −3 dB from the center of the passband).
3. If your measurement needs some noise reduction, you can reduce the IF bandwidth or
add averaging.
• To reduce the IF bandwidth, press.
• To add averaging, press. Toggle to ON.
Chapter 22-11
Avg
Avg
Quick Start: Learning How to Make Measurements
RECALL STATE
MODE MENU
REF=1
MARKER 2
MARKER MODE MENU
STATS
Learning to Make Transmission Measurements
Measuring Passband Flatness or Ripple.
Passbandflatness (or ripple) is the variation in insertion loss over a specified portion of the
passband.
Continue with the following steps to measure passband flatness or ripple.
1. Press(if necessary, scroll to the desired file using
panel keys). Press to recall the error-corrected transmission
Save/Recall
theandfront
measurement that has no markers engaged.
2. Press and turn the front panel knob to move marker 1 to the left edge of the
Marker
passband.
3. Press to change the marker 1 position to the delta
∆
∆
reference point.
4. Pressand turn the front panel knob to move marker 2 to the right edge of
the passband.
5. Press. Toggle to ON.
Marker Fctn
The analyzer calculates the mean, standard deviation, and peak-to-peak variation
between the ∆ reference marker and the active marker, and lists the results in the
upper-right corner of the display. The passband ripple is automatically shown as the
peak-to-peak variation between the markers.
Figure 2-7Example Measurement of Passband Flatness or Ripple
2-12Chapter2
Quick Start: Learning How to Make Measurements
Learning to Make Reflection Measurements
Learning to Make Reflection Measurements
This example procedure shows you how to measure the reflection response of a 125 MHz
bandpass filter. The measurement parameter values listed are unique to this particular
test device.
For further measurement examples, refer to the "Making Measurements" chapter in the
User's Guide.
NOTEReflection measurements monitor only one port of a test device. When a test
device has more than one port, you must ensure that the unused port(s) are
terminated in their characteristic impedance (for example, 50Ω or 75Ω). If
you do not terminate unused ports, reflections from these ports will cause
measurement errors. Figure 2-8 on page 2-14 illustrates two ways to
terminate an unused device port with the proper characteristic impedance.
The signal reflected from the device under test is measured as a ratio of the reflected
energy versus the incident energy. It can be expressed as reflection coefficient, return loss,
or standing-wave-ratio (SWR). These measurements are mathematically defined as
follows:
reflection coefficient (Γ)= reflected voltage / incident voltage
= S11 or S22 (magnitude and phase)
magnitude of reflection
coefficient (ρ)
return loss (dB)= −20 log (ρ), where (ρ) = |Γ|
standing-wave-ratio (SWR)
=|Γ|
= V
maximum
/ V
minimum
= (1 + ρ) / (1 −ρ)
Chapter 22-13
Quick Start: Learning How to Make Measurements
Refl: FWD S11 (A/R)
REFLECTION
AUTO SCALE
AVERAGING FACTOR
AVERAGING
Learning to Make Reflection Measurements
Step 1. Choose measurement parameters with your test device
connected
1. Press the key to return the analyzer to a known state.
Preset
2. Connect your test device as shown in Figure 2-8. If using a load, make sure it has the
correct characteristic impedance.
CAUTIONDamage may result to the device under test if it is sensitive to the analyzer's
default output power level. To avoid damaging a sensitive DUT, be sure to set
the analyzer's output power to an appropriate level before connecting the
DUT to the analyzer.
Figure 2-8 Connections for Reflection Measurements
3. Choose the following measurement parameters:
Meas
Center10.24G/n
Span1G/n
Scale Ref
Avg
or
32x1
. Toggle to ON.
4. Look at the device response to determine if these are the measurement parameters that
you want. For example, if the trace is noisy you may want to increase the input power,
reduce the IF bandwidth, or add averaging. Or, to better see an area of interest, you
may want to change the test frequencies.
2-14Chapter2
Quick Start: Learning How to Make Measurements
CAL KIT
SELECT CAL KIT
N 50
7mm
RETURN
CALIBRATE MENU
S11 1-PORT
REFLECTION 1-PORT
SHORT (M)
DONE 1-PORT CAL
DONE 1-PORT CAL
SAVE STATE
Learning to Make Reflection Measurements
Step 2. Make a measurement calibration
Follow these instructions to perform an S11 or reflection 1-port error correction:
1. Select a calibration kit that is appropriate to your device under test. Press
Cal
. Choose the calibration kit that is appropriate to your
test device by pressing the appropriate softkey. For example, if your test device uses
type-N 50Ω connectors, press. If your test device uses 7-mm connectors, press
Ω
, and so on.
2. Press twice, or
.
3. Follow the prompts shown on the analyzer display to connect and measure an open,
short, and load on PORT 1 or the REFLECTION port.
Any choice of male/female in the calibration process should always be made for the sex
that represents the test port. For example, if the test port had a male, type-N connector,
you would connect the female, type-N calibration device. But when you follow the
prompts on the analyzer to measure a short calibration standard, you would select
, or the sex that represents the test port.
CAUTIONTo ensure an accurate error correction, you must connect the calibration
standards to the adapters or cables that you will include in the actual device
measurement.
NOTEIf a mistake is made, standards can be measured more than once before
pressing. Only the last measurement data is used.
Figure 2-9Connections for an S11 or Reflection 1-Port Error-Correction
4. Press after measuring the three standards.
5. Press.
Save/Recall
6. Press to complete the process.
Chapter 22-15
Quick Start: Learning How to Make Measurements
AUTO SCALE
Learning to Make Reflection Measurements
Step 3. Measure the device
Measuring Return Loss.
1. Connect your device to PORT 1 or the REFLECTION port.
2. Press to reposition the trace.
3. Press to read the return loss from the analyzer display as shown in
Scale Ref
Marker
Figure 2-10.
The device response indicates that the filter and the analyzer impedances are better
matched within the frequency range of the filter passband than outside the passband.
That is, the reflected signal is smaller within the filter passband than outside the
passband.
In terms of return loss, the value within the passband is larger than outside the
passband. A large value for return loss corresponds to a small reflected signal just as a
large value for insertion loss corresponds to a small transmitted signal.
Figure 2-10 Example Measurement of Return Loss
2-16Chapter2
Quick Start: Learning How to Make Measurements
MORE
TITLE
ERASE TITLE
DONE
SYSTEM CONTROLLER
PRINT MONOCHROME
Learning to Make Reflection Measurements
Step 4. Output measurement results
This step in the procedure shows you how to output the measurement results to a printer.
For in-depth information on creating a hardcopy of the measurement results, refer to the
"Printing, Plotting, and Saving Measurement Results" chapter in the User's Guide.
1. Connect a printer to the analyzer as described in “To Configure the Analyzer with
Printers or Plotters” on page 1-11.
2. Press and then create a title for the
Display
measurement, as shown in Figure 2-11:
• Use an optional keyboard to type the title, or
• Use the front panel knob and the softkey menu to select each letter of the title.
3. Presswhen you finish creating the measurement title. The title appears on the
upper-left corner of the analyzer display.
4. Press to set up the analyzer as the controller. If you
Local
are using an HP-IB printer, ensure that there is not another controller on the bus. (Note
that this step is not required when using parallel or serial printers.)
5. Press to create a black and white hardcopy.
Copy
NOTEIf you encounter a problem when printing a hardcopy, refer to “To Configure
the Analyzer with Printers or Plotters” on page 1-11.
Figure 2-11 Example Measurement Title
Chapter 22-17
Quick Start: Learning How to Make Measurements
RECALL STATE
LIN MAG
AUTO SCALE
Learning to Make Reflection Measurements
Measuring Other Reflection Characteristics
You can derive several important filter parameters from the measurement shown on the
analyzer display. The following set of procedures is a continuation of the previous
reflection measurement procedure.
Measuring Reflection Coefficient
1. Press to recall the calibrated reflection measurement
Save/Recall
that you saved earlier in this procedure.
2. Press so the analyzer shows the same
Format
Scale Ref
data in terms of reflection coefficient, as shown in Figure 2-12.
The units "mU" displayed on the analyzer are "milli-units," where "units" or "U" is used
to indicate that the parameter is unitless (as opposed to dB in log magnitude format).
For example,
200 mUnits = 0.2.
Figure 2-12 Example Reflection Coefficient Measurement Trace
2-18Chapter2
Measuring Standing Wave Ratio (SWR)
SWR
AUTO SCALE
Quick Start: Learning How to Make Measurements
Learning to Make Reflection Measurements
Press so the analyzer shows the same data in
Format
Scale Ref
terms of standing-wave-ratio (SWR), as shown in Figure 2-13.
Now the analyzer shows the measurement data in the unitless measure of SWR where
SWR = 1 (perfect match) at the bottom of the display.
Figure 2-13 Example Standing-Wave-Ratio Measurement Trace
Chapter 22-19
Quick Start: Learning How to Make Measurements
POLAR
AUTO SCALE
MARKER MODE MENU
POLAR MKR MENU
LIN MKR
LOG MKR
Re/Im MKR
Learning to Make Reflection Measurements
Measuring S11 and S22 or Reflection in a Polar Format.
1. Press.
2. Press to reposition the trace, as shown in Figure 2-14.
The analyzer shows the results of an S
Format
Scale Ref
or reflection measurement with each point on
11
the polar trace corresponding to a particular value of both magnitude and phase. The
center of the circle represents a coefficient (Γ) of 0, (that is, a perfect match or no
reflected signal). The notation 2U FS or 2 units full scale indicates that the
outermost circumference of the scale shown in Figure 2-14 represents ρ = 2.00, or 200%
reflection. The phase angle is read directly from this display. The 3 o'clock position
corresponds to zero phase angle, (that is, the reflected signal is at the same phase as the
incident signal). Phase differences of 90°, 180°, and −90° correspond to the 12 o'clock, 9
o'clock, and 6 o'clock positions on the polar display, respectively.
3. Press.
Marker Fctn
4. Turn the front panel knob to position the marker at any desired point on the trace, then
read the frequency, linear magnitude and phase in the upper right-hand corner of the
display.
• Choose if you want the analyzer to show the linear magnitude and the
phase of the marker.
• Chooseif you want the analyzer to show the logarithmic magnitude and
the phase of the active marker. This is useful as a fast method of obtaining a reading
of the log-magnitude value without changing to log-magnitude format.
• Chooseif you want the analyzer to show the values of the marker as a
real and imaginary pair.
NOTEYou can also enter the frequency of interest, from either the numeric keypad
or the optional attached keyboard, and read the magnitude and phase at that
point.
Figure 2-14 Example S
or Reflection Measurement Trace in Polar Format
11
2-20Chapter2
Quick Start: Learning How to Make Measurements
SMITH CHART
AUTO SCALE
MARKER MODE MENU
SMITH MKR MENU
LIN MKR
LOG MKR
Re/Im MKR
Learning to Make Reflection Measurements
Measuring S11 and S22 or Reflection in a Smith Chart Format.
• Measuring Impedance
The amount of power reflected from a device is directly related to the impedance of the
device and the measuring system. Each value of the reflection coefficient (Γ) uniquely
defines a device impedance; Γ = 0 only occurs when the device and analyzer impedance are
exactly the same. The reflection coefficient for a short circuit is: Γ = 1 ∠ 180°. Every other
value for Γ also corresponds uniquely to a complex device impedance, according to the
equation:
Z
= [(1 + Γ) / (1 −Γ)]×Z
L
0
where ZL is your test device impedance and Z0 is the measuring system's characteristic
impedance (usually 50Ω or 75Ω).
1. Press.
2. Press and turn the front
Format
Marker Fctn
Scale Ref
panel knob to read the resistive and reactive components of the complex impedance at
any point along the trace, as shown in Figure 2-15. Here the complex impedance is
6.4729 – j7.5569 Ω . This is the default Smith chart marker.
The marker annotation also gives the series inductance or capacitance (132.87 pF in
this example). The complex impedance is capacitive in the bottom half of the Smith
chart display and is inductive in the top half of the display.
• Choose if you want the analyzer to show the linear magnitude and the
phase of the reflection coefficient at the marker.
• Chooseif you want the analyzer to show the logarithmic magnitude and
the phase of the reflection coefficient at the active marker. This is useful as a fast
method of obtaining a reading of the log magnitude value without changing to log
magnitude format.
• Choose if you want the analyzer to show the values of the reflection
coefficient at the marker as a real and imaginary pair.
• Choose(the default marker format) to show the real and imaginary parts
R+jX MKR
of the device impedance at the marker. Also shown is the equivalent series
inductance or capacitance (the series resistance and reactance, in ohms).
Chapter 22-21
Quick Start: Learning How to Make Measurements
Learning to Make Reflection Measurements
Figure 2-15 Example Impedance Measurement Trace
• Measuring Admittance
To change the display to an inverse Smith chart graticule and the marker information to
read admittance, press.
G+jB MKR
As shown in Figure 2-16, the marker reads admittance data in the form G+jB, where G is
conductance and B is susceptance, both measured in units of Siemens (equivalent to mhos:
the inverse of ohms). Also shown is the equivalent parallel capacitance or inductance.
Figure 2-16 Example Admittance Measurement Trace
2-22Chapter2
Quick Start: Learning How to Make Measurements
If You Encounter a Problem
If You Encounter a Problem
If you have difficulty when installing or using the analyzer, check the following list of
commonly encountered problems and troubleshooting procedures. If the problem that you
encounter is not in the following list, refer to additional troubleshooting sections in the
Service Guide.
Power-Up Problems
If the analyzer display does not light:
• Check that the power cord is fully seated in both the main power receptacle and the
analyzer power module.
• Check that the AC line voltage selector switch is in the appropriate position
(230 V/115 V) for your available power supply.
• Check that the analyzer AC line fuse is not open.
WARNINGFor continued protection against fire hazard, replace the fuse with
the same type and rating.
Refer to Figure 2-17 to remove the fuse from the power module. You can use a
continuity light or an ohmmeter to check the fuse. An ohmmeter should read very close
to zero ohms if the fuse is good. For 115V operation, use a 5A 125V TD fuse (HP part
number 2110-1059). For 230V operation, use a T 4A 250V fuse (HP part number
2110-0734).
• Contact the nearest Hewlett-Packard office for service, if necessary. A list of
Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-26.
Figure 2-17 Line Fuse Removal and Replacement
Chapter 22-23
Quick Start: Learning How to Make Measurements
SOURCE PWR
If You Encounter a Problem
If the display lights, but the ventilation fan does not start:
❏ Check that the fan is not obstructed. To check the fan, follow these steps:
1. Switch the LINE power to the off position.
2. Check that the fan blades are not jammed.
❏ Contact the nearest Hewlett-Packard office for service, if necessary. A list of
Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-26.
Data Entry Problems
If the data entry controls (keypad, knob, arrow keys) do not respond:
❏ Check that the ENTRY OFF function is not enabled.
The ENTRY OFF function is enabled after you press the key. To return to
Entry Off
normal entry mode, press any function key that has a numeric parameter associated
with it, for example,.
Start
❏ Check that none of the keys are stuck.
❏ Check that the selected function key accepts data.
For example, accepts data, but does not.
Scale RefSystem
❏ Check that the analyzer's "R" HP-IB STATUS light is not illuminated.
If the analyzer's "R" HP-IB STATUS light is illuminated, a test sequence may be
running, or a connected computer controller may be sending commands or instructions
to, or receiving data from, the analyzer. Press if you want to return to LOCAL
Local
control.
If the parameter you are trying to enter is not accepted by the analyzer:
❏ Ensure that you are not attempting to set the parameter greater than or less than its
limit. Refer to the User's Guide for parameter limits.
No RF Output
If there is no RF signal at the front-panel port:
❏ Check that the signal at the test port is switched on.
1. Press and toggle to ON.
Power
NOTEOn ES models, it is possible to set the source power to come from PORT 2
instead of PORT 1, so you must check the power at the correct port. With
factory preset, the power comes from PORT 1.
❏ If you are applying external modulation (AM) to the analyzer, check the external
modulating signal or external gate/trigger signals for problems.
2-24Chapter2
Quick Start: Learning How to Make Measurements
If You Encounter a Problem
CAUTIONIf the error message:
CAUTION: OVERLOAD ON INPUT X, POWER REDUCED
appears on the analyzer display, too much source power is being applied at
the input. In such a case, the input power will need to be reduced before the
source power will remain on.
❏ If phase-lock error messages appear on the analyzer display, check that the front panel
jumper is secure on the R CHANNEL connectors. If the jumper is secure and the error
messages still appear, contact your nearest Hewlett-Packard office for service. A list of
Hewlett-Packard sales and service offices is provided in Table 2-1 on page 2-26.
Chapter 22-25
Quick Start: Learning How to Make Measurements
If You Encounter a Problem
Table 2-1 Hewlett-Packard Sales and Service Offices
UNITED STATES
Instrument Support Center
Hewlett-Packard Company
(800) 403-0801