92
For a sine wave with a resistive
load at 0° to 40° C, within an output
frequency range of 45 Hz to 1000 Hz,
and in ac coupled mode after a
30 minute warm-up unless
otherwise noted.
ac Input Ratings notes:
1Measured at low line
2 Measured at high line
Ordering Information
Opt 019 2000 VA ac Power source/
analyzer (6813B only)
Opt 020 Dual power analyzer option
Opt 026 26 Volt, 0.1A auxiliary
reference output (6812B only)
Opt 0BN Service Manual,
extra Operating Guide, and
ProgrammingGuide
Opt 1CM Rack-mount Kit,
p/n 5062-3977 (quantity 2)
(support rails required)
Opt 1CP Rack-mount Kit with Handles,
p/n 5062-3983 (support rails required)
6811B, 6812B, 6813B only
Support rails, p/n 12679B, required when rack
mounting the 6811B, 6812B, and 6813B Opt 1CM
and Opt 1CP
Opt 100 (6811B and 6812B only)
87 to 106 Vac (100 Vac nominal),
47-63 Hz, Japan only
Opt 120 104-127 Vac
(120 Vac nominal), 47-63 Hz
Opt 200 (6813B only) 174-220 Vac
(200 Vac nominal), 47-63 Hz, Japan only
Opt 208 (6811B and 6812B only)
174 to 220 Vac (208 Vac nominal),
47-63 Hz
Opt 230 191 to 254 Vac
(230 Vac nominal), 24-63 Hz
Opt 831 12 AWG, 200 to 240 Vac,
unterminated (6812B, 6813B only)
Opt 832 4 mm2wire size, unterminated
(6813B only)
Opt 833 1.5 mm2wire size, 200 to
240 Vac, unterminated (6812B only)
Opt 834 10 AWG, 100 to 120 Vac,
unterminated (6812B only)
ac Power Source/Analyzers: 375-1750 VA
(Continued)
Specifications
(at 0˚to 55˚C unless
otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent ac Power Source/Analyzers an integrated ac power solution
6811B 6812B 6813B
Supplemental Characteristics (Non-warranted characteristics determined by design that are
(Continued)
useful in applying the product)
Average measurement resolution
rms voltage 10 mV 10 mV 10 mV
rms current 2 mA 2 mA 2 mA
Programmable output impedance
resistance 0-1 Ω 0-1 Ω 0-1 Ω
inductance 20 µh - 1 mh 20 µh - 1 mh 20 µh - 1 mh
Remote sense capability Up to 1 Vrms can be Up to 1 Vrms can be Up to 1 Vrms can be
dropped across each dropped across each dropped across each
load lead. load lead. load lead.
Isolation to ground 300 Vrms/425 Vdc 300 Vrms/425 Vdc 300 Vrms/425 Vdc
Net weight 28.2 kg (62 lb) 28.2 kg (62 lb) 32.7 kg (72 lb)
Shipping weight 31.8 kg (70 lb) 31.8 kg (70 lb) 36.4 kg (80 lb)
Dimensions See drawings on page 105
ac Input Ratings
Voltage range (Vac) 87 to 106 Vac 87 to 106 Vac 174 to 220 Vac
*default factory setting *104 to 127 Vac *104 to 127 Vac *191 to 254 Vac
174 to 220 Vac 174 to 220 Vac
191 to 254 Vac 191 to 254 Vac
Maximum input current (rms)
1
12 A (100 Vac) 28 A (100 Vac) 22 A (200/208 Vac)
10 A (120 Vac) 24 A (120 Vac)
7.5 A (200/208 Vac) 15 A (200/208 Vac) 20 A (230 Vac)
6.5 A (230 Vac) 13 A (230 Vac)
Input power (max)
2
1000 VA/700 W 2500 VA/1400 W 3800 VA/2600 W
Input frequency 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
Opt 841 Line Cord with NEMA L6-20P;
20 A 250 V Plug (6812B only)
Opt 842 Line Cord with IEC 309;
32 A 220 V plug (6813B only)
Opt 844 Line Cord with NEMA L6-30P;
30 A 250 V Locking Plug (6813B only)
Opt 845 Line Cord with IEC 309;
16 A 220 V Plug (6812B only)
Opt 846 Line Cord with NEMA L6-30P;
30 A 120 V Plug (6812B only)
Opt 847 Line Cord with CEE 7/7;
16 A 220 V Plug (6812B only)
Opt 848 Line Cord with BS 546;
15 A 240 V Plug (6812B only)
For ac Line Cord and Cord Options
information see pages 93-98.