Agilent 6681A Data Sheet

Reliable dc power for manufacturing test and long-term burn-in
This series of 5000 watt dc power supplies has the exceptional, proven reliability that test system engineers look for. It also has the features needed for easy test system integration.
Programming of the dc output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified by using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes.
The 6680A Series has extremely low ripple and noise for a 5000 watt dc power supply. This helps the built-in measurement system make extremely accurate current and voltage measurements.
Selectable compensation is provided for problem-free powering of inductive loads.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0˚to 55˚C unless otherwise specified)
6680A 6681A 6682A 6683A 6684A 6680A-
J04
Special Order Option
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
48
Proven reliabilty Increase test throughput
with fast up and down programming
Fast reaction to analog programming signals
6680A-6684A
Single-Output: 5000 W GPIB
Number of outputs 111111 GPIB Yes Yes Yes Yes Yes Yes Output ratings
Voltage 0 to 5 V 0 to 8 V 0 to 21 V 0 to 32 V 0 to 40 V 0 to 3.3 V Current (40
˚
C then derate linearly 0 to 875 A 0 to 580 A 0 to 240 A 0 to 160 A 0 to 128 A 0 to 1000 A
1%/˚C from 40˚C to 55˚C)
Programming accuracy
at 25˚C ±5˚C Voltage 0.04% + 5 mV 8 mV 21 mV 32 mV 40 mV 5 mV Current 0.1% + 450 mA 300 mA 125 mA 85 mA 65 mA 450 mV
Ripple and noise constant voltage mode
from 20 Hz to 20 MHz
rms 1.5 mV 1.5 mV 1.0 mV 1.0 mV 1.0 mV 3.4 mV
Peak to peak 10 mV 10 mV 10 mV 10 mV 10 mV 15 mV Readback accuracy at 25˚C ±5˚C (percent of reading plus fixed) Voltage 0.05% + 7.5 mV 12 mV 32 mV 48 mV 60 mV 7.5 mV Current 0.1% + 600 mA 400 mA 165 mA 110 mA 90 mA 600 mA
Load and line regulation
Voltage 0.002% + 0.19 mV 0.3 mV 0.65 mV 1.1 mV 1.5 mV 0.19 mV Current 0.005% + 65 mA 40 mA 17 mA 12 mA 9 mA 77 mA Transient response time Less than 900 µs for the output voltage to recover within 150 mV following
a change in load from 100% to 50%, or 50% to 100% of the output current rating of the supply
Supplemental Characteristics (Non-warranted characteristics determined by design that are
useful in applying this product)
Ripple and noise constant current mode
from 20 Hz to 20 MHz
rms 290 mA 190 mA 40 mA 28 mA 23 mA
Average programming resolution
Voltage 1.35 mV 2.15 mV 5.7 mV 8.6 mV 10.8 mV 12 mV Current 235 mA 155 mA 64 mA 43 mA 34 mA 260 mA OVP 30 mV 45 mV 120 mV 180 mV 225 mV 25 mV
Output voltage programming response time 9 ms 12 ms 45 ms 60 ms 60 ms 9 ms
(excludes command-processing time)
Full-load progrmming rise or fall time (10 to 90% or 90 to 10%, resistive load)
Output common-mode noise current rms 1.5 mA 1.5 mA 3 mA 3 mA 3 mA 2.0 mA
(to signal-ground peak-to-peak 10 mA 10 mA 20 mA 20 mA 20 mA 12.5 mA binding post)
Note 1: Option 6680A-JO4 is not available outside the USA because certification process is not complete.
49
Supplemental Characteristics for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±60 Vdc maximum from chassis ground
Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load.
Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for power supplies connected directly to the GPIB
Modulation: (analog programming of output voltage and current):
Input Signal: 0 to –5 V for voltage,
0 to +5 V for current
Input Impedance: 30 k/or greater
ac Input (47 to 63 Hz): 180 to 235 Vac
(line-to-line, 3 phase), 27.7 A rms maximum worst case, 21.4 A rms nominal; 360 to 440 Vac, 14.3 A rms maximum worst case, 10.7 A rms nomi­nal (maximum line current includes 5% unbalanced phase voltage condition.) Output voltage derated 5% at 50 Hz and below 200 Vac.
Input Power: 7350 VA and 6000 W maximum; 160 W at no load
GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI command set.
Size: 425.5 mm W x 221.5 mm H x
674.7 mm D (16.75 in x 8.75 in x 25.56 in) See page 104 for more details
Weight: Net, 51.3 kg (113 lbs); shipping, 63.6 kg (140 lbs)
Warranty Period: Three years
Ordering Information
Opt 208 180 to 235 Vac, 3 phase,
47 to 63 Hz Opt 400 360 to 440 Vac, 3 phase,
47 to 63 Hz Opt 602 Two Bus Bar Spacers for
paralleling power supplies (p/n 5060-3514)
* Opt 908 Rack-mount Kit
(p/n 5062-3977 and p/n 5063-9212)
* Opt 909 Rack-mount Kit with Handles
(p/n 5063-9221 and p/n 5063-9219). Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual Opt 0B0 No Documentation Package
* Support rails required
Accessories p/n 5060-3513 Three 30-A Replacement
Fuses for 180 to 235 Vac line p/n 5060-3512 Three 16-A Replacement
Fuses for 360 to 440 Vac line E3663AC Support rails for Agilent
rack cabinets
p/n 5080-2148 Serial link cable 2m (6.6 ft.)
Single-Output: 5000 W GPIB (Continued)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization