Agilent 6651A Data Sheet

This series of 500 W linear-regulated dc power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast up and down programming time.
Valuable assemblies can be destroyed by a minor component failure that causes a surge of current to flow into the DUT. Fast protection features, including fast crowbar, mode crossover protection, and the ability to connect the protection circuitry of multiple power supplies can increase production yield.
Programming of the dc output and the protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIPlug&Play drivers. The out­put voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes.
Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0˚to 55˚C unless otherwise specified)
6651A 6652A 6653A 6654A 6655A 6651A-
J01
Special Order Option
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
33
Increase test throughput with fast up and down programming time Protect valuable assemblies with fast protection features Proven reliability Low ripple and noise
6651A-6655A
Single-Output: 500 W GPIB
Number of outputs 111111 GPIB Yes Yes Yes Yes Yes Yes Output ratings
Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V 10 V Output current (40˚C) 0 to 50 A 0 to 25 A 0 to 15 A 0 to 9 A 0 to 4 A 50 A Maximum current (50˚C/55˚C)
45 A/42.5 A 22.5 A/21.3 A 13.5 A/12.8 A 8.1 A/7.7 A 3.6 A/3.4 A 45 A/42.5 A
Programming accuracy
at 25˚C ±5˚C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV 6 mV Current 0.15% + 60 mA 25 mA 13 mA 8 mA 4 mA 60 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 300 µV 300 µV 400 µV 500 µV 700 µV 300 µV peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV 3 mV Current rms 25 mA 10 mA 5 mA 3 mA 2 mA 2 5 mA Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed) System models only
Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV 7.5 mV +Current 0.15% + 67 mA 26 mA 15 mA 7 mA 3 mA 6 7 mA –Current 0.35% + 100 mA 44 mA 24 mA 15 mA 7 mA 100 mA
Load regulation
Voltage 1 mV 2 mV 3 mV 4 mV 5 mV 1 mV Current 2 mA 1 mA 0.5 mA 0.5 mA 0.5 mA 2 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV 0.5 mV Current 2 mA 1 mA 0.75 mA 0.5 mA 0.5 mA 2 mA Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2 mV 5 mV 10 mV 15 mV 30 mV 2.5 mV Current 15 mA 7 mA 4 mA 2.5 mA 1.25 mA 15 mA OVP 12 mV 30 mV 54 mV 93 mV 190 mV 16 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V 200 mV
34
Supplemental Characteristics for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±240 Vdc from chassis ground
Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load.
Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB
Output Programming Response Time:
The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms.
Down Programming: An active down programmer sinks approximately 20% of the rated output current
Modulation: (Analog programming of output voltage and current)
Input signal: 0 to –5 V Input impedance: 10 k Ohm nominal
ac Input: (ac input frequency 47 to 63 Hz)
Voltage 100 Vac 120 V ac 220 Vac 240 Vac Current 12 A 10 A 5.7 A 5.3 A
Input Power: 1,380 VA, 1,100 W at full load;
120 W at no load GPIB Interface Capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI-compatible com­mand set.
Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x 19.6 in) See page 101 for more details
Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb)
Warranty Period:One year
Single-Output: 500 W GPIB (Continued)
Specifications
(at 0˚to 55˚C unless otherwise specified)
6651A- 6651A- 6652A- 6653A- 6653A­J03 J09 J03 J04 J17
Special Order Special Order Special Order Special Order Special Order Option Option Option Option Option
Number of outputs 11111 GPIB Yes Yes Yes Yes Yes Output ratings
Output voltage 6 V 17V/20 V 27 V 40 V 30 V Output current (40˚C) 60 A 30 A/15 A 18.5 A 12.5 A 17.5 A Maximum current (50
˚
C/55˚C)
54 A/5 1A 27 A/25.5 A 16.65 A/15.72 A 11.25 A/10.6 A 15.75 A/14.87 A
13.5 A/12.75 A
Programming accuracy
at 25˚C ±5˚C
Voltage 0.06% + 5 mV 10 mV 13.5 mV 17.5 mV 15 mV Current 0.15% + 75 mA 36 mA 25 mA 13 mA 16 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 300 µV 300 µV 450 µV 1.6 mV 400 µV peak-peak 3 mV 4 mV 4.5 mV 5 mV 4 mV Current rms 30 mA 13 mA 10 mA 5 mA 6 mA Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed) System models only
Voltage 0.07% + 6 mV 15 mV 20.5 mV 30 mV 25 mV +Current 0.15% + 80 mA 40 mA 26 mA 15 mA 18 mA –Current 0.35% + 150 mA 55 mA 44 mA 24 mA 28 mA
Load regulation
Voltage 1 mV 2 mV 2 mV 3.5 mV 3 mV Current 6.5 mA 2 mA 1 mA 1 mA 0.5 mA
Line regulation
Voltage 0.5 mV 0.5 mV 0.5 mV 1 mV 1 mV Current 2 mA 2 mA 2 mA 0.75 mA 0.75 mA Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2 mV 5 mV 6.75 mV 12mV 10 mV Current 18 mA 9 mA 7 mA 4 mA 5 mA OVP 12 mV 30 mV 30 mV 65 mV 54 mV OVP accuracy 160 mV 500 mV 400 mV 750 mV 700 mV
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization
35
Ordering Information
Opt 100
87 to 106 Vac, 47 to 63 Hz
Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz
*Opt 908 Rack-mount Kit
(p/n 5062-3977)
*Opt 909 Rack-mount Kit
w/ Handles (p/n 5063-9221) Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual Opt 0B0 No documentation package
*Support rails required
Accessories
p/n 1494-0059 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link
Cable 2 m (6.6 ft) E3663AC Support rails for
Agilent rack cabinets
Single-Output: 500 W GPIB (Continued)
Specifications
(at 0˚to 55˚C unless otherwise specified)
6654A- 6654A- 6654A- 6655A- 6655A­J04 J05 J12 J05 J10
Special Order Special Order Special Order Special Order Special Order Option Option Option Option Option
Number of outputs 11111 GPIB Yes Yes Yes Yes Yes Output ratings
Output voltage 70 V 50 V 80 V 150 V 156 V Output current (40˚C) 7.5 A 10 A 6 A 3.2 A 3 A Maximum current (50˚C/55˚C)
6.75 A/6.37 A 9 A/8.5 A 5.4 A/5.1 A 2.88 A/2.72 A 2.7 A/2.55 A
Programming accuracy
at 25˚C ±5˚C Voltage 0.06% + 30 mV 26 mV 35 mV 64 mV 71 mV Current 0.15% + 7 mA 9 mA 7 mA 3.5 mA 4 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 600 µV 500 µV 700 µV 800 µV 900 µV peak-peak 6 mV 5 mV 7 mV 8 mV 8 mV Current rms 5 mA 4 mA 3 mA 2 mA 3 mA Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed) System models only
Voltage 0.07% + 50 mV 40 mV 58 mV 100 mV 110 mV +Current 0.15% + 6 mA 8 mA 6 mA 2.5 mA 3 mA –Current 0.35% + 13 mA 17 mA 16 mA 6.5 mA 7.5 mA
Load regulation
Voltage 4 mV 4 mV 4 mV 6 mV 7 mV Current 0.5 mA 0.5 mA 0.5 mA 0.5 mA 1 mA
Line regulation
Voltage 1 mV 1 mV 4.5 mV 2 mV 2 mV Current 0.5 mA 0.5 mA 0.5 mA 0.5 mA 1 mA Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 17.5 mV 15 mV 20 mV 37.5 mV 39.5 mV Current 1.9 mA 2.75 mA 1.7 mA 8 mA 8 mA OVP 110 mV 93 mV 130 mV 240 mV 250 mV OVP accuracy 1.4 V 1.2 V 1.6 V 3 V 3.3 V
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization
To see a copy of the user’s guide, please visit our Web site at
www.agilent.com/find/manuals
By internet, phone, or fax, get assistance with all your test & measurement needs
Online assistance:
www.agilent.com/find/assist
Phone or Fax
United States:
(tel) 1 800 829 4444
Canada:
(tel) 1 877 894 4414 (fax) (905) 282-6495
China:
(tel) 800-810-0189 (fax) 1-0800-650-0121
Europe:
(tel) (31 20) 547 2323 (fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (82-2) 2004-5004 (fax) (82-2) 2004-5115
Latin America:
(tel) (305) 269 7500 (fax) (305) 269 7599
Taiwan:
(tel) 080-004-7866 (fax) (886-2) 2545-6723
Other Asia Pacific Countries:
(tel) (65) 375-8100 (fax) (65) 836-0252 Email: tm_asia@agilent.com
Product specifications and descriptions in this document subject to change without notice.
Your Requested Excerpt from the Agilent Power Products Catalog
The preceding page(s) are an excerpt from the 2002-2003 Power Products Catalog. We hope that these pages supply the information that you currently need. If you would like to have further information about the extensive selection of Agilent dc power supplies, ac sources, and dc electronic loads, please visit
www.agilent.com/find/powerto print a copy of the complete Power Products
catalog, or to request that a copy be sent to you. You will also find a lot of other useful information on this web site.
In the full Power Products Catalog, you will find that Agilent offers much more than basic power generation. If you need basic, clean, power for your lab bench, it’s there. But in each product category, we’ve also integrated the capabilities that you need for a complete power solution, including extensive measurement and analysis capabilities.
Please give us a call at your local Agilent Technologies sales office, or call a regional office listed below, for assistance in choosing or using Agilent power products.
Keep up to date with Agilent’s Test and Measurement Email Updates
As an Email Update subscriber, you will receive periodic customized email updates that match the areas of interest that you have specified. Your update will include products and services, applications and support information, events, and promotions. Sign up today at www.agilent.com/find/emailupdates. Check off dc power supplies, ac power sources or electronic loads on your registration form, and we will promptly let you know what’s new in power products! Our Privacy Statement at www.agilent.com/go/privacy describes our commitment to you regarding your privacy.
Agilent Technologies
Loading...