34
Supplemental Characteristics
for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±240 Vdc from chassis
ground
Remote Sensing: Up to half the rated output
voltage can be dropped in each load lead.
The drop in the load leads subtracts from
the voltage available for the load.
Command Processing Time: Average time
required for the output voltage to begin to
change following receipt of digital data is
20 ms for the power supplies connected
directly to the GPIB
Output Programming Response Time:
The rise and fall time (10/90% and 90/10%)
of the output voltage is less than 15 ms.
The output voltage change settles within
1 LSB (0.025% x rated voltage) of final
value in less than 60 ms.
Down Programming: An active down
programmer sinks approximately 20%
of the rated output current
Modulation: (Analog programming of
output voltage and current)
Input signal: 0 to –5 V
Input impedance: 10 k Ohm nominal
ac Input: (ac input frequency 47 to 63 Hz)
Voltage 100 Vac 120 V ac 220 Vac 240 Vac
Current 12 A 10 A 5.7 A 5.3 A
Input Power: 1,380 VA, 1,100 W at full load;
120 W at no load
GPIB Interface Capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP0, DC1, DT1, E1, and C0.
IEEE-488.2 and SCPI-compatible command set.
Regulatory Compliance: Listed to UL 1244;
conforms to IEC 61010-1.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x 19.6 in)
See page 101 for more details
Weight: Net, 25 kg (54 lb); shipping,
28 kg (61 lb)
Warranty Period:One year
Single-Output: 500 W GPIB (Continued)
Specifications
(at 0˚to 55˚C unless
otherwise specified)
6651A- 6651A- 6652A- 6653A- 6653AJ03 J09 J03 J04 J17
Special Order Special Order Special Order Special Order Special Order
Option Option Option Option Option
Number of outputs 11111
GPIB Yes Yes Yes Yes Yes
Output ratings
Output voltage 6 V 17V/20 V 27 V 40 V 30 V
Output current (40˚C) 60 A 30 A/15 A 18.5 A 12.5 A 17.5 A
Maximum current (50
˚
C/55˚C)
54 A/5 1A 27 A/25.5 A 16.65 A/15.72 A 11.25 A/10.6 A 15.75 A/14.87 A
13.5 A/12.75 A
Programming accuracy
at 25˚C ±5˚C
Voltage 0.06% + 5 mV 10 mV 13.5 mV 17.5 mV 15 mV
Current 0.15% + 75 mA 36 mA 25 mA 13 mA 16 mA
Ripple and noise
from 20 Hz to 20 MHz
Voltage rms 300 µV 300 µV 450 µV 1.6 mV 400 µV
peak-peak 3 mV 4 mV 4.5 mV 5 mV 4 mV
Current rms 30 mA 13 mA 10 mA 5 mA 6 mA
Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed)
System models only
Voltage 0.07% + 6 mV 15 mV 20.5 mV 30 mV 25 mV
+Current 0.15% + 80 mA 40 mA 26 mA 15 mA 18 mA
–Current 0.35% + 150 mA 55 mA 44 mA 24 mA 28 mA
Load regulation
Voltage 1 mV 2 mV 2 mV 3.5 mV 3 mV
Current 6.5 mA 2 mA 1 mA 1 mA 0.5 mA
Line regulation
Voltage 0.5 mV 0.5 mV 0.5 mV 1 mV 1 mV
Current 2 mA 2 mA 2 mA 0.75 mA 0.75 mA
Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater)
following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2 mV 5 mV 6.75 mV 12mV 10 mV
Current 18 mA 9 mA 7 mA 4 mA 5 mA
OVP 12 mV 30 mV 30 mV 65 mV 54 mV
OVP accuracy 160 mV 500 mV 400 mV 750 mV 700 mV
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization