Agilent 6641A Data Sheet

This series of 200 W linear-regulated dc power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast up and down programming time.
Valuable assemblies can be destroyed by a minor component failure that can allow a surge of voltage or current to flow to the DUT. Fast protection features, including fast crowbar, mode crossover protection, and the ability to connect the protection circuitry of multiple power supplies can increase production yield.
Programming of the dc output and the protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIPlug&Play drivers. The out­put voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes.
Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0˚to 55˚C unless otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
29
Increase test throughput with fast up and down programming time Protect valuable assemblies with fast protection features Proven reliability Low ripple and noise
6641A - 6645A
Single-Output: 200 W GPIB
6641A 6642A 6643A 6644A 6645A
Number of outputs 11111 GPIB Yes Yes Yes Yes Yes Output ratings
Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current (40°C) 0 to 20 A 0 to 10 A 0 to 6 A 0 to 3.5 A 0 to 1.5 A Maximum current (50°C/55°C) 18 A/17 A 9 A/8.5 A 5.4 A/5.1 A 3.2 A/3 A 1.4 A/1.3 A Programming accuracyat 25°C ±5°C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV Current 0.15% + 26 mA 13 mA 6.7 mA 4.1 mA 1.7 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 300 µV 300 µV 400 µV 500 µV 700 µV
peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV Current rms 10 mA 5 mA 3 mA 1.5 mA 1 mA Readback accuracy at 25°C ±5°C
(percent of reading plus fixed) Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV +Current 0.15% + 18 mA 9.1 mA 5 mA 3 mA 1.3 mA
-Current 0.35% + 40 mA 20 mA 12 mA 6.8 mA 2.9 mA
Load regulation
Voltage 1 mV 2 mV 3 mV 4 mV 5 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA
Line regualtion
Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Transient response time Less than 100 µs for the output voltage to recover to its previous level (within 0.1% of
the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2 mV 5 mV 10 mV 15 mV 30 mV Current 6 mA 3 mA 2 mA 1.2 mA 0.5 mA OVP 13 mV 30 mV 54 mV 93 mV 190 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V
30
Supplemental Characteristics for all model numbers
dc Floating Voltage: Output terminals
can be floated up to ±240 Vdc from chassis ground
Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load.
Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB
Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms.
Down Programming: An active down programmer sinks approximately 20% of the rated output current
Modulation: (Analog programming of output voltage and current) Input Signal: 0 to –5 V Input Impedance: 10 k Ohm nominal
ac Input: (ac input frequency 47 to 63 Hz)
Voltage 100 Vac 120 Vac 220 Vac 240 Vac Current 4.4 A 3.8 A 2.2 A 2.0 A
Input Power 480 VA, 400 W at full load;
60 W at no load GPIB Interface Capabilities SH1, AH1, T6,
L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI-compatible com­mand set
Regulatory Compliance: Complies with UL 3111-1, IEC 61010-1.
Size: 425.5 mm W x 88.1 mm H x 439 mm D (16.75 in x 3.5 in x 17.3 in) See page 101 for more details.
Weight: Net, 14.2 kg (31.4 lb); shipping,
16.3 kg (36 lb)
Warranty Period: Three years
Single-Output: 200 W GPIB (Continued)
Specifications
(at 0˚to 55˚C unless otherwise specified)
6641A- 6643A- 6644A- 6645A- 6645A­J04 J11 J09 J05 J06
Special Order Special Order Special Order Special Order Special Order Option Option Option Option Option
Number of Outputs 11111 GPIB Yes Yes Yes Yes Yes Output ratings
Output voltage 13 V 40 V 70 V 150 V 170 V Output current (40˚C) 15.3 A 5 A 3 A 1.2 A 1 A Maximum current (50˚C/55˚C) 13.77 A/13 A 4.5 A/4.25 A 2.7 A/2.55 A 1.08 A/1.02 A 0.9 A/0.85 A
Programming accuracy
at 25˚C ±5˚C
Voltage 0.06% + 8.5 mV 17.5 mV 31 mV 65 mV 74 mV Current 0.15% + 21 mA 6.7 mA 4.1 mA 1.7 mA 1.7 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 300 µV 450 µV 600 µV 900 µV 1 mV
peak-peak 3 mV 3.5 mV 6 mV 9 mV 10 mV
Current rms 8 mA 3 mA 1.5 mA 1 mA 1 mA
Readback accuracy at 25˚C ±5˚C (percent of reading plus fixed)
Voltage 0.07% + 10 mV 30 mV 47 mV 100 mV 140 mV +Current 0.15% + 15 mA 5 mA 3 mA 1.3 mA 1.3 mA –Current 0.35% + 40 mA 12 mA 6.8 mA 2.9 mA 2.9 mA
Load regulation
Voltage 1 mV 3 mV 4.5 mV 7 mV 8 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA
Line regulation
Voltage 0.5 mV 1 mV 1.5 mV 2.5 mV 3 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA Transient response time Less than 100 µs for the output voltage to recover to its previous level (within 0.1% of
the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 3.5 mV 12 mV 1.4 mV 37.5 mV 42.5 mV Current 5 mA 2 mA 1.2 mA 0.5 mA 0.5 mA OVP 23 mV 62 mV 110 mV 250 mV 285 mV OVP accuracy 260 mV 800 mV 1.5 mV 3 V 3.4 V
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Ordering Information
Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz
Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5063-9212) * Opt 909 Rack-mount Kit w/ Handles
(p/n 5063-9219)
Opt 0L2 Extra Standard Documentation
Package
Opt 0B3 Service Manual
Opt 0B0 No Documentation Package * Support rails required
Accessories p/n 1494-0060 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link Cable
2 m (6.6 ft) E3663AC Support rails for Agilent
rack cabinets
To see a copy of the user’s guide, please visit our Web site at
www.agilent.com/find/manuals
By internet, phone, or fax, get assistance with all your test & measurement needs
Online assistance:
www.agilent.com/find/assist
Phone or Fax
United States:
(tel) 1 800 452 4844
Canada:
(tel) 1 877 894 4414 (fax) (905) 282-6495
China:
(tel) 800-810-0189 (fax) 1-0800-650-0121
Europe:
(tel) (31 20) 547 2323 (fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (82-2) 2004-5004 (fax) (82-2) 2004-5115
Latin America:
(tel) (305) 269 7500 (fax) (305) 269 7599
Taiwan:
(tel) 080-004-7866 (fax) (886-2) 2545-6723
Other Asia Pacific Countries:
(tel) (65) 375-8100 (fax) (65) 836-0252 Email: tm_asia@agilent.com
Product specifications and descriptions in this document subject to change without notice.
Your Requested Excerpt from the Agilent Power Products Catalog
The preceding page(s) are an excerpt from the 2002-2003 Power Products Catalog. We hope that these pages supply the information that you currently need. If you would like to have further information about the extensive selection of Agilent dc power supplies, ac sources, and dc electronic loads, please visit
www.agilent.com/find/powerto print a copy of the complete Power Products
catalog, or to request that a copy be sent to you. You will also find a lot of other useful information on this web site.
In the full Power Products Catalog, you will find that Agilent offers much more than basic power generation. If you need basic, clean, power for your lab bench, it’s there. But in each product category, we’ve also integrated the capabilities that you need for a complete power solution, including extensive measurement and analysis capabilities.
Please give us a call at your local Agilent Technologies sales office, or call a regional office listed below, for assistance in choosing or using Agilent power products.
Keep up to date with Agilent’s Test and Measurement Email Updates
As an Email Update subscriber, you will receive periodic customized email updates that match the areas of interest that you have specified. Your update will include products and services, applications and support information, events, and promotions. Sign up today at www.agilent.com/find/emailupdates. Check off dc power supplies, ac power sources or electronic loads on your registration form, and we will promptly let you know what’s new in power products! Our Privacy Statement at www.agilent.com/go/privacy describes our commitment to you regarding your privacy.