Agilent 6632B Data Sheet

This series of linear-regulated 80-100 W dc power supplies is designed to maximize the throughput of DUTs through the manufacturing test process. Both programming and measurement are optimized for speed. The active downprogrammer can sink up to the full rated current of the power supply, which quickly brings the power supply output to zero volts. The 6630B Series offers many advanced programmable features including stored states and status reporting. Programming is done using industry standard SCPI commands via the GPIB or RS-232. Test system integration is further simplified by using the VXIPlug&Play drivers. The optional relays simplify system design and troubleshooting.
The optional front panel binding posts make the 6630B Series convenient on the R&D lab bench. The built-in microamp measurement system helps the engineer to easily and accurately monitor the output voltage and current without a complicated test setup.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0˚to 55˚C unless otherwise specified)
6631B 6632B 6633B 6634B
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
27
Increase production throughput with fast programming speed Active downprogrammer sinks the full rated current Protect valuable prototypes with fast protection features Accurate and fast built-in measurement system
6631B - 6634B
Single-Output: 80-100 W GPIB
Number of outputs 1111 GPIB Yes Yes Yes Yes Output ratings
Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V Current 0 to 10 A 0 to 5 A 0 to 2 A 0 to 1 A Programming accuracy at 25°C ±5°C Voltage 5 mV 10 mV 20 mV 50 mV + Current 0.05% + 4 mA 2 mA 1 mA 0.5 mA Ripple and noise (20 Hz to 20 MHz, with outputs
ungrounded or with either terminal grounded) Voltage Normal mode rms 0.3 mV 0.3 mV 0.5 mV 0.5 mV
peak-to-peak 3 mV 3 mV 3 mV 3 mV
Fast mode rms 1 mV 1 mV 1 mV 2 mV
peak-to-peak 10 mV 10 mV 15 mV 25 mV Current rms 3 mA 2 mA 2 mA 2 mA dc measurement accuracy via GPIB or front panel
meters with respect to actual output at 25°C ±5°C Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV Low current range –20 mA to +20 mA 0.1% + 2.5 µA 2.5 µA 2.5 µA 2.5 µA High current range +20 mA to + rated I 0.2% + 1 mA 0.5 mA 0.25 mA 0.25 mA
–20 mA to –rated I 0.2% + 1.6 mA 1.1 mA 0.85 mA 0.85 mA
Load regulation
Voltage 2 mV 2 mV 4 mV 5 mV Current 2 mA 1 mA 1 mA 1 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA Transient response timeLess than 100 µs (50 µs in the fast mode) for the output voltage to recover to its previous
level (within 0.1% of the voltage rating of the supply or 20 mV) following any step change in load current of up to 50% of the output current rating of the supply.
28
Supplemental Characteristics for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±240 Vdc maximum from chassis ground
Remote Sensing: Up to two volts dropped in each load lead. Add 2 mV to the voltage load regulation specification for each one volt change in the positive output lead due to load current change.
Command-Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 4 ms for the power supplies connected directly to the GPIB. (Display disabled).
Output-Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 2 ms (400 µs in fast mode). The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 6 ms (2 ms in the fast mode).
GPIB Interface Capabilities: IEEE-488.2, SCPI command set and 6630A Series programming compatability
Measurement Time: Average time to make a voltage or current measurement is 50 ms.
Input Power (full load): 3.5 A, 250 W Regulatory Compliance: Complies with
EMC directive 89/336/EEC (ISM 1B).
Warranty Period:One year Size: 425.5 mm W x 88.1 mm H x
364.4 mm D (16.8 in x 3.5 in x 14.3 in). See page 103 for more information
Weight: Net, 12.7 kg (28 lb) net;
15.0 kg (33 lb) shipping
Single-Output: 80-100 W GPIB (Continued)
Specifications
(at 0˚to 55˚C unless otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0˚to 55˚C unless otherwise specified)
6631B 6632B 6633B 6634B
Supplemental Characteristics (Non-warranted characteristics determined by design and useful
in applying the product)
Average programming resolution
Voltage 2 mV 5 mV 12.5 mV 25 mV Current 2.5 mA 1.25 mA 0.5 mA 0.25 mA
Sink current 10 A 5 A 2 A 1 A Sink current tracking
SCPI mode 0.4% + 0.4% + 0.4% + 0.4% +
4 mA 2 mA 1 mA 0.5 mA Compatability mode -500 mA -250 mA -100 mA -50 mA Minimum current in constant current mode* 40 mA 20 mA 8 mA 4 mA
*When programming in the 6630A Series language compatibility mode.
Ordering Information
Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 230 207 to 253 Vac, 47 to 63 Hz Opt 020 Front-panel Binding Posts Opt 760 Isolation and Reversal Relays
(N/A on 6631B)
* Opt 1CM Rack-mount Kit,
p/n 5063-9212
* Opt 1CP Rack-mount Kit with Handles,
p/n 5063-9219 Opt 0L2 Additional standard
documentation package Opt 0B3 Service Manual
* Support rails required
Accessories p/n 1494-0060 Rack Slide Kit E3663AC Support rails for Agilent
rack cabinets
Loading...
+ 1 hidden pages