Microfiche Part No. 60503-90008 Printed: June, 1991
Page 2
DECLARATION OF CONFORMITY
according to ISO/IEC Guide 22 and EN 45014
Manufacturer’s Name: Hewlett-Packard Co.
Manufacturer’s Address: New Jersey Division
150 Green Pond Road
Rockaway, NJ 07866 U.S.A.
declares that the product
Product Name:Load mainframe and modules
Model Number(s): HP 6050A, 6051A mainframes with modules
HP 60501A/B, 60502A/B, 60503A/B, 60504A/B, 60507A/B
conform(s) to the following Product Specifications:
Safety:IEC 348:1978 / HD401 S1:1981
1
EMC:CISPR 11:1990 / EN 55011:1991 - Group 1, Class B
IEC 801-2:1991 / EN 50082-1:1992 - 4kV CD, 8 kV AD
IEC 801-3:1984 / EN 50082-1:1992 - 3 V/m
IEC 801-4:1988 / EN 50082-1:1992 - 0.5 kV Sig. Lines, 1 kV
Power Lines
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC
Directive 89/336/EEC and carries the CE-marking accordingly.
Note 1: The product family was introduced prior to 12/93
New JerseyJanuary 1997_________________________________
Location DateBruce Krueger / Quality Manager
European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH,
Department TRE, Herrenberger Strasse 130, D-71034 Boeblingen (FAX:+49-7031-14-3143)
Page 3
240-Volt Module
About This Manual
This manual provides information for the HP 60503B 250-Watt Electronic Load Module. It is designed as a supplement
to the HP 6050A/6051A Multiple Input Mainframe Electronic Load Operating Manual (part number 06050-90001). Four
tables provide the following module-specific information:
Table 60503-1 lists both the specifications and supplemental characteristics of the module. Specifications indicate
warranted performance in the 25 °C ± 5 °C region of the total temperature range (0 to 55° C). Supplemental
characteristics indicate non-warranted, typical performance and are intended to provide additional information by
describing performance that has been determined by design or type testing.
Table 60503-2 lists the ranges that can be programmed in constant current, constant resistance, and constant voltage
modes. It shows the maximum and minimum programming values for each range. Refer to this table when programming
the module locally as described in chapter 4, or remotely as described in chapter 5 of the operating manual.
Table 60503-3 gives the factory default values of the module. Unless you have saved your own wake-up settings, the
module will be set to the factory default values whenever power is applied. See chapter 4 in the operating manual.
Table 60503-4 provides calibration information for the module. This information is needed to perform the annual
calibration procedure described in chapter 6 of the operating manual.
Module Installation and Operation
Except for the module-specific information in this manual, all installation, operation, and calibration instructions are
given in the Mainframe Operating Manual. The HP Electronic Load Family Programming Reference Manual (part
number 06060-90005) contains complete programming details that apply to all Electronic Load models.
Note:The following information in chapter 2 of the Mainframe Operating Manual does not apply to electronic
load modules with the serial numbers listed on the title page of this manual: The section titled
"Extended Power Operation", and the section titled "Extended Power Limit". Also for these modules,
change the 3-second delay referred to under "Nominal Power Limit" to 50 milliseconds.
Items Supplied
In addition to this manual, a 10-pin connector plug is also shipped with your Electronic Load module. Refer to chapter 3
in the operating manual for more information.
1
Page 4
Table 60503-1. Specification and Supplemental Characteristics
SPECIFICATIONS
DC Input Rating:
Current: 0 to 10 A
Voltage: 3 V to 240 V (minimum dc operation from 0 to 2 V for 0 to 10 A)
Power: 250 W at 40 °C (derated to 187 W at 55 °C)
A. OPERATING CHARACTERISTICS B. DERATED CURRENT DETAIL
Constant Current Mode:
Ranges:0 to 1 A; and 0 to 10 A
Accuracy: (after 30 second wait): ± 0.15% ± 10 mA (both ranges)
Resolution: 0.26 mA (1 A range); 2.6 mA (10 A range)
Regulation:8 mA (both ranges)
Temperature Coefficient:150 ppm/°C ± l mA/°C (both ranges)
Constant Resistance Mode:
Ranges:0.20 to 24 Ω; 24 Ω to 10 kΩ; and 240 Ω to 50 kΩ
Accuracy:± 0.8% ± 200 mΩ with ≥ 1 A at input (24 Ω range);
Resolution:6 mΩ (24 Ω range); 0.011 mS (10 kΩ range); 0.001 mS (50 kΩ range)
Regulation:10 mV with remote sensing (24 Ω range); 8 mA (10 k and 50 kΩ ranges)
Temperature Coefficient:800 ppm/°C ± 10 mΩ/°C (24 Ω range);
Constant Voltage Mode:
Range:0 to 240 V
Accuracy:± 0.12% ± 120 mV
Resolution: 64 mV
Regulation: 10 mV (remote sense); 40 mV (local sense)
Temperature Coefficient:120 ppm/°C ± 10 mV/°C
± 0.3% ± 0.3 mS with ≥ 24 V at input (10 k and 50 kΩ ranges)
300ppm/°C ± 0.03 mS/°C (10 k and 50 kΩ ranges)
2
Page 5
Table 60503-1 Specifications and Supplemental Characteristics (continued)
Transient Operation:
Continuous Mode
Frequency Range:0.25 Hz to 10 kHz
Frequency Resolution:4%
Frequency Accuracy:3%
Duty Cycle Range:3% to 97% (0.25 Hz to 1 kHz); 6% to 94% (1 kHz to 10 kHz)
Duty Cycle Resolution:4%
Duty Cycle Accuracy:6% of setting ± 2%
Pulsed Mode
Pulse Width: 50 µs ± 3% minimum; 4 s ± 3% maximum
Transient Current Level (0 to 1 A and 0 to 10 A ranges):
Resolution:4 mA (1 A range); 43 mA (10 A range)
Accuracy:± 0.18% ± 13 mA (1 A range); ± 0.18% ± 50 mA (10 A range)
Temperature Coefficient:180 ppm/°C ± 1.2 mA/°C
Transient Resistance Level (0.20 to 24 Ω, 24 Ω to 10 kΩ, and 240 Ω to 50 kΩ ranges):
Resolution:100 mΩ (24 Ω range); 0.18 mS (10 kΩ range); 0.018 mS (50 kΩ range)
Accuracy:± 0.8% + 200 mΩ with > 1 A at input (24 Ω range)
± 0. 3% + 0.5 mS with ≥ 24 V at input (10 kΩ range)
± 0.3% + 0.4 mS with ≥ 24 V at input (50 kΩ range)
Transient Voltage Level (0 to 240 V):
Resolution: 1.0 V
Accuracy: ± 0.15% ± 1.1 V
Temperature Coefficient: 120 ppm/°C ± 10 mV/°C
Current Readback:
Resolution: 2.7 mA (via HP-IB); 10 mA (front panel)
Accuracy:(after 30 minute wait): ± 0.12% ± 10 mA
Temperature Coefficient: 100 ppm/ °C ± l mA/ °C
Voltage Readback:
Resolution:67 mV (via HP-IB); 100 mV (front panel)
Accuracy:± 0.1% ± 150 mV
Temperature Coefficient:100 ppm/°C ± 8 mV/°C
Maximum Readback Capability:260 V (typical)
Power Readback:
Accuracy: ± 0.2% ± 3 W
3
Page 6
Table 60503-1 Specifications and Supplemental Characteristics (continued)
External Analog Programming 0 to 10 V (dc or ac):
Bandwidth:10 kHz (3 db frequency)
Accuracy:± 3% ± 10 mA (0 to 1 A range)
± 3% ± 20 mA (0 to 10 A range)
± 0.5% ± 150 mV (0 to 240 V range)
Temperature Coefficient:150 ppm/°C ± 1 mA/°C (current ranges)
120 ppm/°C ± 10 mV/°C (voltage range)
External Current Monitor (0 to 10 V):
Accuracy: ± 3% ± 10 mA (referenced to analog common)
Temperature Coefficient:100 ppm/°C ± l mA/°C
External Voltage Monitor (0 to 10 V):
Accuracy: ± 0.4% ± 240 mV (referenced to analog common)
Temperature Coefficient: 70 ppm/ °C ± 1.2 mV/ °C
Remote Sensing: 5 Vdc maximum between sense and input binding posts
Maximum Input Levels:
Current:10.2 A (programmable to lower limits)
Voltage: 250 V
Minimum Operating Voltage:2 V (derated to 0 V at 0 A)
PARD (20 Hz to 10 MHz noise):
Current:1 mA rms/10 mA p-p
Voltage: 6 mV rms
DC Isolation Voltage: ± 240 Vdc between + or - input binding post and chassis ground
Digital Inputs:
Vlo:0.9 V maximum at Ilo = -1 mA
Vhi3.15 V minimum (pull-up resistor on input)
Digital Outputs:
Vlo:0.72 V maximum at Ilo = 1 mA
Vhi: 4.4 V minimum at Ilo - 20 µA
SUPPLEMENTAL CHARACTERISTICS
Programmable Slew Rate (For any given input transition, the time required will be either the total slew time or a
minimum transition time, whichever is longer. The minimum transition time increases when operating with input
currents under 0.2 A and decreases with input currents over 2 A. The following are typical values; ± 25% tolerance):
4
Page 7
Table 60503-1 Specifications and Supplemental Characteristics (continued)
Current Slew Rate:*
Rate #10 A Range Step1 A Range StepTransition Time
Resistance Slew Rate (24 Ω range): Uses the value programmed for voltage slew rate.
Resistance Slew Rate (10 k and 50 kΩ ranges): Uses the value programmed for current slew rate.
Transient Current Overshoot (When programmed from 0A):
RangeTransient Current LevelCurrent Slew RateOvershoot*
10 A2-10 AAll slew rates0
0.5 A
0.5 A0.17 A/ms to 42 A/ms0
1 A
1 A
1 A0.5 A8.3 A/ms4%
0.5 A0.17 A/s and 0.17 A/ms0
1 AAll slew rates0
*All overshoot values assume a total inductance of lµH, or less, in the load leads connected to the D.U.T.
0.17 A/µs to 0.83 A/µs
0.83 A/µs
0.17 A/ms to 0.17 A/µs
5
5%
1%
0
Page 8
Table 60503-1 Specifications and Supplemental Characteristics (continued)
Source Turn-On Current Overshoot: Less than 5% of final value (in CC and CR modes when connected to power
supplies with voltage rise times of greater than 500µs).
Programmable Short Circuit: 0.20 Ω (0.10 Ω typical)
Programmable Open Circuit: 80 kΩ (typical)
Drift Stability (over an 8 hour interval):
Current:±0.03% ±1.5 mA
Voltage:±0.01% ±20 mV
Reverse Current Capacity: 20 A when unit is on; 10 A when unit is off
Weight:3.2 kg (7 lbs.)
Table 60503-2. Programming Ranges
FunctionFront PanelFront PanelHP-SL CommandRange of Values
KeyDisplay(Short Form)
Constant Current
Set RangeC:RNG value"CURR:RANG value"
Low Range
High Range
Set Main LevelCURR value"CURR value"
Low Range0 to 1 A
High Range0 to 10 A
Set Slew Rate
Low Range
High Range
Set Transient LevelC:TLV value"CURR:TLEV value"same as main level
*Set Triggered Level"CURR:TRIG value"same as main level
Constant Resistance
Set RangeR:RNG value"RES:RANG value"
Low Range
Middle Range
High Range
Set Main LevelRES value"RES value"
Low Range
Middle Range
High Range
Set Slew Rate
Low RangeV:SLW value"VOLT:SLEW value"same as voltage slew
Middle/High RangeC:SLW value"CURR:SLEW value"same as current slew
Set Transient LevelR:TLV value"RES:TLEV value"same as main level
*Set Triggered Level"RES:TRIG value"same as main level
Constant Voltage
Set Main LevelVOLT value"VOLT value"0 to 240 V
Set Slew Rate
Set Transient LevelV:TLV value"VOLT:TLEV value"same as main level
*Set Triggered Level"VOLT:TRIG value"same as main level
(shift)
(shift)
(shift)
C:SLW value"CURR:SLEW value"
V:SLW value"VOLT:SLEW value"
≥ 0 and ≤ 1 A
> l A and ≤ 10 A
0.000007 to .083 (A/µs)
0.00017 to 0.83 (A/µs)
≥ 0 and ≤ 24 Ω
> 24 Ω and ≤ 24 kΩ
>24 kΩ and ≤ 24 kΩ
0 to 24 Ω
24 Ω to 24 kΩ
240 Ω to 240 kΩ
0.004 to 2 (V/µs)
6
Page 9
Table 60503-2. Programming Ranges (continued)
FunctionFront PanelFront PanelHP-SL CommandRange of Values
KeyDisplay(Short Form)
Transient Operation
Set FrequencyFREQ value"TRAN:FREQ value"0.25 Hz to 10 kHz
Set Duty Cycle
*Set Pulse Width"TRAN:TWID value"0.00005 to 4 s
Trigger Operation
*Set Trigger Period"TRIG:TIM value"0.000008 to 4 s
Current Protection
*Set Current Level"CURR:PROT value"0 to 10.2 A
*Set Delay Time"CURR:PROT:DEL value"0 to 60 s
**Can only be programmed remotely via the HP-IB.
***Continuous transient mode is the only mode available at the front panel. Pulsed, toggled, and continuous modes can
all be programmed remotely via the HP-IB.
7
Page 10
Table 60503-4. Calibration Information
Ranges and
Calibration Points
High Current RangeHi_curr_rng1025 V/10.5 A15 A
High Current OffsetHi_curr_offset0.0048
Low Current RangeLo_curr_rng125 V/2 A15 A
Low Current OffsetLo_curr_offset0.0032
Voltage RangeN/AN/A246 V/0.6 AN/A
Voltage Hi pointVolt_hipt240
Voltage Lo pointVolt_lopt2
Low Resistance RangeLo_res_rng2460 V/1.82 A15 A
Low Resistance Hi pointLo_res_hipt23.9
Low Resistance Lo pointLo_res_lopt0.88
Middle Resistance RangeMid_res_rng24043.6 V/4 A15 A
Middle Resistance Hi pointMid_res_hipt500
Middle Resistance Lo pointMid_res_lopt24
High Resistance RangeHi_res_rng24020240 V/2 A15 A
High Resistance Hi pointHi_res_hipt2000
High Resistance Lo pointHi_res_lopt240
VariablesVariables
Value
Power Supply
Settings
Current
Shunt
8
Page 11