Agilent 54620C Data Sheet

HP 54600-Series Oscilloscopes
Analog feel and digital power for precise, accurate troubleshooting at an affordable price
Enhance your troubleshooting capability at an affordable price
The HP 54600 family of oscilloscopes provide the familiar, easy-to-use controls and interactive displays you’ve grown accustomed to on analog scopes. Yet, to solve your most difficult test problems, these scopes provide powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. The eight models in this family give you the features and performance you need for confidence in your critical measurements, at a fraction of the price you’d expect to pay.
Displays you can trust
HP 54600-series oscilloscopes feature real-time vector displays that give you a clear and accurate picture of your waveforms. Like analog oscilloscope displays, these enhanced displays give you waveform slew rate information at a glance, with brighter traces representing more slowly changing waveforms and dimmer traces representing more rapidly changing waveforms. These trace intensity differences give you the visual information you need to quickly assess waveform slew rate, for faster, more effective trouble­shooting.
The multi-processor architecture of HP 54600-series oscilloscopes delivers a display update rate of over 500,000 points per second (up to 3 million points per second on the HP 54645A). This fast display update means the oscilloscope screen reflects changes in the waveform instantaneously, giving you the display responsiveness you need to make adjustments quickly and see complex waveforms accurately.
In vector mode, HP 54600-series oscilloscopes, provide a fast screen refresh rate of 60 times/second, regardless of the number of waveforms displayed, and minimal display blind time so you can capture and display infrequent events that other scopes might miss.
H
• 60/100/150/500 MHz bandwidth
• Choice of: high sample rates, 4 channels, deep memory, or color display models
• Real-time vector display
• Automatic measurements
• Pre-trigger viewing, trace storage
• Optional remote control/hard copy
Powerful digital features
The digital architecture of HP 54600-series oscilloscopes gives you a multitude of features that help you get your job done easier and faster:
• Pre-trigger viewing capability lets you view events that you’d miss with an analog scope. This feature lets you see what happened before the trigger event, so you can troubleshoot more effectively.
• Autoscale frees you from resetting the scope every time you move the probe from test point to test point. You simply hit the autoscale button and it sets voltage, time and trigger parameters for you.
• With autostore, the waveform displays at full brightness while all previously acquired waveforms remain on the scope’s screen at half brightness. This lets you see a history of waveform activity while simultaneously viewing the live waveform. You can use this tool to analyze worst­case jitter and noise, or to permanently capture infrequent waveform anomalies.
• Automatic measurements of voltage, frequency and time, plus user-defined cursor measurements, make waveform characterization fast and easy.
• With peak detect, you won’t have to worry about missing narrow glitches.
Choose from models designed to meet your needs
The HP 54600 series includes eight models designed to meet your needs and your budget.
HP 54600B 100 MHz oscilloscope
With 100 MHz bandwidth, two input channels and sweep speeds from 2ns/div to 5 s/div, the HP 54600B is ideal for production, test, field service and education, or anywhere you need a solid, dependable scope.
HP 54645A MegaZoom oscilloscope
The HP 54645A oscilloscope brings the advantages of deep memory with none of the disadvantages usually associated with this class of oscilloscopes. The HP 54645A is a dual-channel 100 MHz oscilloscope with 200 MSa/s and a full 1 MB of memory behind each of its channels. Through the application of MegaZoom technology, this deep memory oscilloscope has a high speed/low dead time display and a highly responsive front panel. Unlike all other deep memory
2
scopes which force the user to choose between fast response and deep memory, the MegaZoom technology gives you a scope that is always fast and deep. Pan and zoom operation is as simple as turning the time/division knob. No special menus or controls are required to take full advantage of the HP 54645A’s deep memory.
A powerful glitch trigger extends the power of the MegaZoom technology in solving your toughest troubleshooting problems. Simply set-up the desired pulse width that represents a worse case situation and after the scope finds it, pan and zoom through the deep waveform record to find out exactly what was going on in your circuit that caused the problem.
HP 54602B 4-channel oscilloscope
When you need more bandwidth than the HP 54600B and HP 54645A provide, take a closer look at the HP 54602B scope. You get the same capabilities as with the HP 54600B but with the added advantage of a 150 MHz bandwidth, 4 (2+2) channels and 1mV/div sensitivity.
HP 54603B 60 MHz oscilloscope
For colleges and universities with tight budgets, this scope is a great way to introduce students to the world of professional test equipment. Students can use the 60 MHz , 2-channel HP 54603B to understand circuit operation and learn standard measurement practices on the same type of equipment they are likely to use when they graduate. Sweep speed varies from 5 ns/div to 5s/div.
HP 54610B 500 MHz oscilloscope
Even though the HP 54610B is the least expensive 500 MHz oscilloscope on the market, it has analog performance that is similar
to higher cost oscilloscopes. The HP 54610B is ideal for many production line test applications. This 2-channel, delayed sweep scope offers a viewable external trigger and horizontal accuracy of +0.001%. Sweep speeds range from 1ns/div to 5s/div.
HP 54615B 1 GSa/s oscilloscope
With the HP 54615B you can capture narrow glitches and subtle details of your signal. This 2-channel scope combines 500 MHz bandwidth, 1 GSa/s sample rate and 1 nanosecond peak detection on both channels. The HP 54615B peak detection allows the scope to maintain a 1 GSa/s sample rate at all sweep speeds. A horizontal accuracy of 0.005% means you can make critical timing measurements with confidence.
HP 54616B 2 GSa/s oscilloscope
The top-of-the line HP 54616B offers the same benefits as the 54615B but with twice the sample rate—2GSa/s sampling rate, 500 MHz bandwidth and 1 nanosecond peak detection. Whether you need to verify a one time, 1 ns edge or view the envelope of a modulated waveform, the HP 54616B has the power and flexibility to get the job done. And, the intuitive front panel and responsive display makes this the scope of choice for everyday troubleshooting.
HP 54616C color oscilloscope
The HP 54616C color display makes viewing more interesting and easier when you are viewing multiple waveforms.
3-year warranty
All HP 54600-series oscilloscopes include a full 3-year warranty with optional 5-year warranty coverage. Each scope includes two 1.5 meter 10X voltage probes, a user’s guide, and a power cord.
Technical Specifications
HP 54600B, HP 54602B, HP 54603B, HP 54610B, HP 54615B, HP 54645A and HP 54616B/C Oscilloscopes
HP 54603B HP 54600B HP 54645A HP 54602B HP 54610B HP 54615B/16B/16C
Bandwidth
CH 1 & 2 dc–60 MHz dc–100 MHz dc–100 MHz tt dc–150 MHz* dc–500 MHz dc–500 MHz
ac coupled 10 Hz–60 MHz 10 Hz–100 MHz 1.5 Hz–100 MHz tt 10 Hz–150 MHz* 10 Hz–500 MHz 10 Hz–500 MHz
CH 3 & 4 NA NA NA dc–250 MHz NA NA
Single-shot bandwidth dc–2 MHz dc–2 MHz dc–20 MHz dc–2 MHz dc–2 MHz HP 54615B 250 MHz
Number of channels 2 2 2 4 (2 + 2) 2 2 Sensitivity
CH 1 & 2 2 mV/div to 5 V/div 2 mV/div to 5 V/div 1 mV/div to 5 V/div 1 mV/div to 5 V/div 2 mV/div to 5 V/div 2 mV/div to 5 V/div CH 3 & 4 NA NA NA 0.1 & 0.5 V/div NA NA
dc gain accuracy ±2% ±1.5% ±1.5% ±1.5% ±2% ±2% Rise time (calculated)
CH 1 & 2 <5.83 ns <3.5 ns <3.5 ns <2.33 ns <700 ps <700 ps CH 3 & 4 NA NA NA <1.4 ns NA NA
Input impedance 1 M, approx. 13 pF 1 M, approx. 13 pF 1 M, approx. 13 pF 1 M, approx. 13 pF 1 M, approx. 9 pF 1 M, approx. 9 pF
Input coupling
CH 1 & 2 dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground dc, ac or ground CH 3 & 4 NA NA NA dc, ground NA NA
Maximum input (dc + peak ac) 400 V 400 V 400 V 400 V 250 V or 5 Vrms 250 V or 5 Vrms
or 50 selectable or 50 selectable
in 50 mode in 50 mode
Timebase range (main & delayed) 5 s/div to 5 ns/div 5 s/div to 2 ns/div 50 s/div to 2 ns/div 5 s/div to 2 ns/div 5 s/div to 1 ns/div 5 s/div to 1 ns/div Trigger sources CH 1, 2, line, or ext. CH 1, 2, line, or ext. CH 1, 2, line, or ext. CH 1, 2, 3, 4, or line CH 1, 2, line, or ext. CH 1, 2, line, or ext. Horizontal accuracy ±0.01% ±0.01% ±0.01% ±0.01% ±0.01% ±0.005% Horizontal resolution 100 ps 100 ps 40 ps 100 ps 100 ps 20 ps Trigger sensitivity
dc to 25 MHz 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.35 div or 3.5 mV 0.35 div or 0.7 mV 0.5 div or 2.5 mV*** 0.5 div or 3.5 mV*** dc to max. bandwidth 1 div or 10 mV 1 div or 10 mV 1 div or 10 mV 1 div or 2 mV** 1 div or 5 mV
Maximum sample rate
single shot 20 MSa/s 20 MSa/s 200 MSa/s 20 MSa/s 20 MSa/s HP 54615 1 GSa/s repetitive 10 GSa/s 10 GSa/s >10 GSa/s 10 GSa/s 10 GSa/s >10 GSa/s
Record length (maximum) 4,000 points 4,000 points 1M points 4,000 points 4,000 points 5,000 points
single shot 2,000 points 2,000 points 1M points 2,000 points 2,000 points 5,000 points
Max. display update rate 1,500,000 points/sec 1,500,000 points/sec 3,000,000 points/sec 1,500,000 points/sec 1,500,000 points/sec 500,000 points/sec Resolution 8 bits Power Voltage: 100–240 Vac, 48–440 Hz, 300 VA maximum Net weight Approx. 6.2 kg (14 lbs) Size (excl. handle) 172 mm H x 322 mm W x 317 mm D (6.8 x 12.7 x 12.5 in) Warranty 3 years
HP 54616B 500 MHz
1 div or 7 mV
HP 54616 2 GSa/s
* Maximum bandwidth on CH 1 & 2 is 100 MHz at 1, 2, and 5 mV/div.
** HP 54602B, for ranges 1, 2, and 5 mV/div, sensitivity between 25 MHz and
100 MHz on CH 1 & 2 is 2 div or 4 mV.
*** Trigger sensitivity from dc to 100 MHz.
Trigger sensitivity from 100 MHz to max. bandwidth.
††
Maximum bandwidth on CH 1 & 2 is 75 MHz at 1, 2 and 5 mV/div.
3
Vertical System (HP 54600B, 54645A,
54602B, 54603B)
Bandwidth Limit 20 MHz Inversion CH 1 & CH 2 CMRR 20 dB at 50 MHz Dynamic Range ±8 div from center screen Input R&C 1 M, 13 pf Maximum Input 400 V (dc + peak ac)
Math Functions CH 1 + or – CH 2 Cursor Accuracy [1][2]
Single Cursor Vert. Acc. ± 1.2% of full
scale, ± 0.5% of position value
Dual Cursor Vert. Acc. ±0.4%
of full scale
Vertical System (HP 54610B, 54615B,
54616B/C)
Bandwidth Limit 30 MHz Inversion CH 1 & CH 2 CMRR 20dB at 50 MHz Dynamic Range ±12 div from center screen Input R&C 1 M, 9 pf or 50
selectable
Maximum Input 250 V (dc + peak ac) or
5 Vrms in 50mode
50Protection Protects 50load from
excessive voltage
Time Skew Adjustable over a range of
±25ns to remove effects of cabling
Probe Sense Automatic readout of 1X,
10X, 20X, 50X and 100X probes
Math Functions CH 1 + or – CH 2 Cursor Accuracy [1][2]
Single Cursor Vert. Acc. ± 1.2% of full
scale, ± 0.5% of position value
Dual Cursor Vert. Acc. ±0.4%
of full scale
Horizontal System
Cursor Accuracy ± 0.01% ± 0.2% of full
(t & 1/t) [3] scale ±200 ps
Delay Jitter 10 ppm
Pretrigger Delay 10 div
(Negative time) Posttrigger Delay at least 2,560 div or
(Trigger to start 50 ms. Not to exceed of sweep) 100 s.
1 ppm (54615B, 54616B/C)
Delayed Sweep
Main Sweep Delayed Sweep
5 s/div to 10 ms/div up to 200X main 5 ms/div and faster up to 2 ns/div 54610B, 15B/16B/16C up to 1ns/div
Trigger System
Coupling ac, dc, LF reject, HF reject,
Modes Auto, Autolevel, Normal,
HP 54645A Glitch triggering
TV Triggering TV line and field. 0.5 div of
TV Functions
Line Counting Delay time calibrated in All Field Trigger Oscilloscope triggers on the
(both fields selected, 54602B and 54610B)
Holdoff Adjustable from 200 ns
External Trigger (54600B, 54603B, 54645A) Range Sensitivity ±18V
Coupling dc, HF reject and noise Input R&C 1M, 13pf
Maximum Input 400 V (dc + peak ac)
& noise reject. LF & HF: -3db at 50 kHz
Single, & TV Minimum width 8 ns,
Operators: <, >, or range composite sync for stable
display (Ch1 & Ch2)
NTSC and PAL line numbers vertical sync pulse in both
fields, allowing use with noninterlaced video.
to 13 s
dc to 25MHz: <50mV dc to 100 MHz: <100mV
reject
External Trigger (54610B, 54615B, 54616B/C) Range Sensitivity ±18V
dc to 100MHz: <75mV dc to 500 MHz: <150mV
Coupling dc and ground Input R&C 1M, 12pf or 50
selectable
Maximum Input 250 V (dc + peak ac) or
5 Vrms in 50mode
Trigger View External trigger is viewable. (HP 54610B only) Bandwidth is >350MHz
X-Y Operation
Z-Blanking TTL high blanks trace
(not available on 54615B, 54616B/C)
Bandwidth X & Y same as vertical
system
Phase Difference ± 3 degrees at 100 kHz
± 3 degrees at 10 MHz (54615B, 54616B/C)
Display System
Display 7-inch Raster CRT Resolution 255 vertical by 500
horizontal points
Controls Front-panel intensity control Graticule 8 X 10 grid or frame Autostore Autostore saves previous
sweeps in half bright display and the most recent sweep in full bright display.
Display (54616C) 5.8 inch Active Matrix Color
LCD Display
[1] Temperature ± 10°C from calibration [2] Use full scale at 80mV for 2mV/div and 5 mV/div ranges [3] Use full scale of 50 ns for 2 ns/div
4
Acquisition System
Simultaneous Channels
HP 54600B/54610B, Channels 1& 2
54615B, 54616B HP 54602B Channels 1& 2 or 3& 4 Record Length 4,000 points Vectors off
HP 54615B, 54616B/C 5,000 points HP 54645A 1 million points
Max Update Rate Vectors off: 1,500,000
HP 54615B, 54616B/C 500,000 points/sec HP 54645A 3,000,000 points/sec
Usable Single-Shot 2 MHz, single channel Bandwidth
HP 54615B 250 MHz HP 54616B/C 500 MHz HP 54645A 20 MHz
Peak Detect 50 ns glitch capture (100 ns
HP 54615B, 54616B/C 1 ns glitch capture HP 54645A 5 ns
Average Number of averages
and/or Vectors on
points/sec Vectors on: 60 full screens/sec, independent of number of waveforms being displayed
1 MHz, dual channel
dual channel) at sweep speeds of 50 µs/div and greater
selectable at 8, 64, 256
Advanced Functions
Automatic Measurements are Measurements
Voltage Vavg, Vrms, Vpp, Vtop, Time Frequency, Period, + Width,
Cursors Manually or automatically
Setup Functions
Autoscale Sets the vertical and
Save/Recall 10 front-panel setups Trace Memory Two volatile pixel memories
[1] Tested to Hewlett-Packard Environmental Specification
Section 758 for Class B-1 products
continuously updated Vbase, Vmin, & Vmax – Width, Duty Cycle, Rise
Time, & Fall Time placed
horizontal deflection and the trigger level
General
Power Line Requirements
Line Voltage Range 100 Vac to 240 Vac Line Voltage Selection Automatic Line Frequency 45 Hz to 440 Hz Max Power 220 VA Consumption 300 VA (54615B, 54616B/C)
Environmental The instrument meets Characteristics
Ambient Temperature
Operating –10 °C to +55 °C Nonoperating –51 °C to + 71 °C
Humidity [1] Operating 95% RH at 40°C for 24 Hrs Nonoperating 90% RH at 65°C for 24 Hrs
Altitude
Operating to 4,500 m (15,000 ft) Nonoperating to 15,000 m (50,000 ft)
EMI (Commercial) Meets FTZ 1046 Class B EMI (MIL-T-28800D) Meets requirements in
CE01,CE03 Full limits CS01, CS02, CS06 Full limits
RE01 15 dB relaxation to 20 kHz;
RE02 (With Opt 002) Full limits of class A1c and (Without Opt 002) 10 dB relaxation from RS02 Exceptioned
RS03 (With Opt 001) Slight trace shift from
Vibration Operating: 15 minutes along
Shock Operating: 30 g, 1/2 sine,
Size (excluding handle)
Weight 6.2 kg (14 lbs) Safety CSA Certification,
Warranty 3 years
the requirements of MIL-T­28800D for Type III, Class 3, Style D equipment as described below.
accordance with Paragraph
3.8.3, EMI Type III, and MIL­STD-461C as modified by Table XII.
exceptioned from 20 kHz to 50 kHz
A1f 14 kHz to 100 kHz
80 MHz to 200 MHz each of the 3 major axes;
0.025 inch p-p displacement, 10 Hz to 55 Hz in one-minute cycles. Held for 10 minutes at 55 Hz (4 g at 55 Hz).
11 ms duration, 3 shocks per axis along major axis. Total of 18 shocks
Height: 172 mm (6.8 in) Width: 322 mm(12.7 in) Depth: 317 mm (12.5 in)
IEC 348 UL 1244 listed
Expandable feature set to meet your changing needs
HP 54600-series oscilloscopes can be easily and inexpensively upgraded with add-on modules and software links to provide advanced analysis capability. Accessories and modules available include:
• Interface modules for remote control and hard-copy output to RS-232, HP-IB and parallel printers and plotters. With the addition of these modules, the scope’s two trace memories become nonvolatile.
• Add FFT capability and unattended signal monitoring along with the rest of the basic interface module benefits. Catching intermittent failures is easy with unattended waveform monitoring. The nonvolatile memory can store up to 100 traces.
• HP BenchLink Scope software for transferring screen images and waveform data to Windows applications for further analysis or to create polished reports and presentations. HP BenchLink Scope also lets you store instrument setups.
Enhanced TV/video trigger
With Option 005, six of the HP 54600-series scopes gain the ability to trigger and perform highly detailed measurements on the video components of your system. You can order this option for HP 54602B, HP 54610B, HP 54615B, HP 54616B/C, and HP 54645A oscilloscopes. For more information about this option, request data sheet 5965-1100 EN.
5
HP 54650A HP-IB Interface Module
Provides full remote control and hard copy to HP-IB printers and plotters. Programming is in accordance with IEEE 488.2. With the addition of this module, the scope’s two pixel memories become non-volatile. An operating and programming manual and a programming examples disk are supplied.
Specifications The interface capabilities of
the HP 54600 series oscilloscope with this module installed are as defined by IEEE 488.1 as SH1, AH1, T5, L4, SR1, RL1, PP1, DC1, DT1, C0 and E2.
Printer/Plotter HP ThinkJet, HP QuietJet, Supported HP PaintJet, and HP LaserJet;
HP-GL compatible plotters.
HP 54652B RS-232/Parallel Interface Module
Provides full remote control via RS-232 and printing via parallel in one module. The RS-232 can also be configured for printing when not being used for remote control.
Specifications
Connector Type 9 pin (m) DTEPort, works
with HP 34398A RS-232 cable.
Protocols Xon/Xoff, hardwire Data Bits 8 Parity None Baud Rates 1200, 2400, 9600, or 19200 Printer/Plotter HP ThinkJet, HP QuietJet,
Support HP PaintJet, and HP LaserJet;
HP-GL compatible plotters.
Specifications
Connector Type 25 pin (F) connector, works
with HP C2950A parallel printer cable.
Supported Printers: Epson FX-80 or HP PCL
compatible printers.
HP 54657A and 54659B Measurement/ Storage Modules
With the the addition of either the HP 54657A module with HP-IB interface or the HP 54659B module with RS-232 and parallel interface, the HP 54600 series oscilloscope will provide all of the following features.
19 Automatic Measurements consisting of:
Voltage Vamp, Vavg, Vrms, Vpp,
Vpre, Vovr, Vtop, Vbase, Vmin, and Vmax
Time Delay, Duty Cycle,
Frequency, Period, Phase Angle, Rise Time, Fall Time, + width, and - width
Thresholds User selectable among
10%/90%, 20%/80%, or absolute voltage levels.
Cursor Readout Voltage or percentage Modes Time or phase angle
Waveform Math Functions
Function 1 Addition, subtraction, and Function 2 Differentiation, integration,
FFT
Windows Exponential, flat top, Samples 1024 points
Trace Memory up to 100 nonvolatile Memories 1 – 3 High speed storage without Memories 4 – 100 Storage with compression.
Memory Labeling An onscreen text editor is
Real Time Clock 24-hour format with battery
Unattended Waveform Monitoring
Testing Method Comparison to waveform Number of Masks 2
Mask Generation Automask, controlled from and Operation
multiplication and FFT
Hanning and rectangular
memories compression. Storage time is approxi-
mately 7 seconds. Number of traces that can be stored is a function of complexity, with the minimum being 4 highly complex traces and the maximum being 96.
provided for creating labels up to 20 characters. Each label contains the date and time it was saved.
back-up. Can be set from front panel.
mask.
the front panel, generates mask from displayed waveform with selectable tolerance. Mask editor function allows pixel-by­pixel editing and line drawing. Smoothing function performs a running average of 3 pixels.
Action on Failure • Save failed trace to
Hard Copy and HP 54657A HP-IB Programmability (For HP-IB specifications Interface see HP 54650A)
memory with date and time of the failure
• Print failed trace with date and time of the failure
• Count the failure and maintain pass/fail statistics while continuing the test
HP 54658A RS-232 (For RS-232 specifications see HP 54652B)
6
10442A fine pitch probe 10070A rugged probe
Specifications for HP 54600-Series Scope Probes
Probe Bandwidth Division Approx. Input Approx. Rise- Max Scope Model Ratio length R Input time input Compatibility Number C dc + peak ac
10070A 20 MHz 1:1 1.5m 1 M 70 pF <17.5 ns 400 V HP 54600-series 10071A 150 MHz 10:1 1.5m 10 M 15 pF <2.33 ns 450 V HP 54600/02/03/45B 10073A 500 MHz 10:1 1.5m 1 M 12 pF <0.7 ns 450 V HP 54610/15/16B 10074A 150 MHz 10:1 1.5m 10 M 12 pF < 2.33 ns 450 V HP 54645A 10442A 1 GHz 10:1 2.0m 500 1.2 pF <0.35 ns 10 V scopes with 50 inputs 10444A 500 MHz 10:1 1.6m 1 M 6-15 pF <0.7 ns 450 V HP 54610/15/16B 1137A 1 MHz 1000:1 1.5m 500 M 3 pF <35 ns 5 KV scopes with 1m inputs
Probe Accessories
HP 10072A SMT Probe tips for
HP 1007X probes
This accessory adapts this series of rugged probes to HP logic analyzer style grabbers that can be used in SMT probing applications. Supplied with 8 grabbers.
HP 5081-7705 BNCAdapter for
HP 1007X probes
This accessory clips on the end of the probe and allows the probe to mate with BNC (f) connectors.
HP 5081-7690 Replacement Accessory
Kit for HP 1007X probes
This kit contains replacement Hook Tip, IC Tip, Ground Bayonet, Ground Lead, Adjustment Tool, and Probe Identification Tags.
Additional Measurement Accessories
HP 10100C 50 ±1% Feedthrough
Termination BNC (f) to BNC (m), Frequency range dc-300 MHz, Max. VSWR 1.1:1
HP 11094B 75 ± 0.2% Feedthrough
Termination BNC (f) to BNC (m), maximum power 1 Watt
HP 1251-2277 Dual Banana(m) to BNC (f)
Adapter
HP 10110B Dual Banana(m) to BNC (m)
Adapter
Additional Accessories
HP 10098A Front Panel Cover and
Pouch Kit
This kit will add the Option 101 front panel cover and pouch to any 54600-series oscilloscope
HP 1183A Testmobile Scope
Cart for HP 54600-series scopes
7
Ordering Information
HP 54600-Series Oscilloscopes
HP 54600B Two-channel, 100 MHz Oscilloscope HP 54602B Four-channel, 150 MHz Oscilloscope HP 54603B Two-channel, 60 MHz Oscilloscope
Each of the above oscilloscopes comes with two 1.5 meter 10X probes (HP 10071A), a user’s and service guide, and power cord.
HP 54610B Two-channel, 500 MHz, 20 MSa/s Oscilloscope HP 54615B Two-channel, 500 MHz, 1 GSa/s Oscilloscope HP 54616B Two-channel, 500 MHz, 2 GSa/s Oscilloscope HP 54616C Color two-channel, 500 MHz, 2 GSa/s Oscilloscope HP 54645A Two-channel, 100 MHz, 200 MSa/s Oscilloscope
Each of the above oscilloscopes comes with two 1.5 meter 10X probes (HP 10073A), a user’s and service guide, and power cord.
Options
Opt. 001 RS-03 Magnetic interface shielding added to CR Opt. 002 RE-02 Display shield added to CRT to reduce radiated interface Opt. 005 Enhanced TV/video triggering (not HP 54600B/03B) Opt. 090 Delete probes (for HP 54600/02/03B) Opt. 090 Delete probes (for HP 54610B, 54615B, 54616B/C) Opt. 101 Accessory pouch and front panel cover (HP 10098A) Opt. 102 Two additional HP 10071A probes (HP 54602B only) Opt. 103 Operator training kit (includes training signal board & lab workbook) Opt. 104 Carrying case (protects scope for shipping or baggage checking) Opt. 106 HP BenchLink Scope software for Windows (HP 34810B) Opt. 1CM Rack Mount Kit (P/N 5062-7345) Opt. W50 Additional 2-year warranty (5-year total), starting at
Manual options (please specify one)
ABA US English ABF French ABJ Japanese ABD German ABZ Italian AB1 Korean ABE Spanish ABO Taiwan Chinese
HP 54650-series enhancement modules
HP 54650A HP-IB interface module HP 54652A Parallel interface module HP 54652B RS-232 and parallel interface module HP 54655A HP-IB test automation module (compatible only with 54600/03/02/10B) HP 54656A RS-232 test automation module (compatible only with 54600/03/02/10B) HP 54657A HP-IB measurement/storage module HP 54659B RS-232 and parallel measurement/storage module
Each module includes user’s and programmer’s guides; HP 54656A includes HP 98561-61604 RS-232 adapter cable and one 2-meter RJ-45 cable.
Modules with product numbers ending in “A” are compatible with HP 54600A-series and HP 54600B-series scopes. Modules ending in “B” are compatible with the HP54600-B-series only. The HP 54620A logic analyzer can use any of these modules, but it uses the modules for I/O only.
Additional oscilloscope accessories, probes and terminations
HP 10070A 1:1 probe HP 10071A 10:1 probe HP 10072A SMT probing adapters HP 10073A 10:1 500 MHz probe with readout HP 10074A 10:1 150 MHz probe with readout HP 10442A 10:1 GHz probe for 50 inputs. HP 10444A 10:1 500 MHz mini-probe with readout HP 1137A 1000:1 high-voltage probe HP 10100C 50 feedthrough termination HP 5081-7690 HP 1007X probe accessory kit HP 5081-7705 HP 1007X probe-to-BNC (m) adapter HP 10098A Front panel cover and pouch kit
HP 34327A Inverter, 12 Volt dc to 115 V ac
HP 34810-Series BenchLink Software
HP 34810B BenchLink Scope Software
Includes software on 3.5” disk, user’s guide. (all languages) HP-IB or RS-232 module needed for connection to scope.
For more information on Hewlett-Packard Test and Measurement products, applications or services please call your local Hewlett-Packard sales offices. A current listing is available via the Web through AccessHP at http://www.hp.com. If you do not have access to the internet, please contact one of the HP centers below and they will direct you to your nearest HP representative.
United States:
Hewlett-Packard Company Test and Measurement Organization 23 Inverness Way East Englewood, CO 80112 1 800 452 4844
Canada:
Hewlett-Packard Canada Ltd. 5150 Spectrum Way Mississauga, Ontario L4W 5G1 (905) 206 4725
Europe:
Hewlett-Packard European Marketing Centre P.O. Box 999 1180 AZ Amstelveen The Netherlands
Japan:
Hewlett-Packard Japan Ltd. 3-29-21 Takaido-higashi Suginami Ku Tokyo 168, Japan Tel: (81-333) 31-6111 Fax: (81-333) 35-1478
Latin America:
Hewlett-Packard Latin American Region Headquarters 5200 Blue Lagoon Drive, 9th Floor Maimi, FL 33126 U.S.A. (305) 267 4245 /4220
Australia/New Zealand:
Hewlett-Packard Australia Ltd. 31-41 Joseph Street, Blackburn Victoria 3130, Australia 131 347 Ext. 2902
Asia Pacific:
Hewlett-Packard Asia Pacific Ltd. 17-21/F Shell Tower, Time Square 1 Matheson Street, Causeway Bay Hong Kong (852) 2599 7070
Within Budget. Without Compromise.
Technical data subject to change without notice. HP BenchLink is a trademark of
Hewlett-Packard Company. Microsoft® Windows
trademarks of Microsoft Corporation. Copyright © 1996
Hewlett-Packard Company Printed in the U.S.A. 8/96 5964-9339 EN
TM
and MS-DOS are registered
Loading...