Analog feel and digital power for
precise, accurate troubleshooting at
an affordable price
Enhance your troubleshooting
capability at an affordable price
The HP 54600 family of
oscilloscopes provide the familiar,
easy-to-use controls and interactive
displays you’ve grown accustomed
to on analog scopes. Yet, to solve
your most difficult test problems,
these scopes provide powerful
digital features, such as pre-trigger
viewing, waveform storage, and
measurement automation. The
eight models in this family give you
the features and performance you
need for confidence in your critical
measurements, at a fraction of the
price you’d expect to pay.
Displays you can trust
HP 54600-series oscilloscopes
feature real-time vector displays
that give you a clear and accurate
picture of your waveforms. Like
analog oscilloscope displays, these
enhanced displays give you
waveform slew rate information at
a glance, with brighter traces
representing more slowly changing
waveforms and dimmer traces
representing more rapidly changing
waveforms. These trace intensity
differences give you the visual
information you need to quickly
assess waveform slew rate, for
faster, more effective troubleshooting.
The multi-processor architecture of
HP 54600-series oscilloscopes
delivers a display update rate of over
500,000 points per second (up to
3 million points per second on the
HP 54645A). This fast display update
means the oscilloscope screen
reflects changes in the waveform
instantaneously, giving you the
display responsiveness you need to
make adjustments quickly and see
complex waveforms accurately.
In vector mode, HP 54600-series
oscilloscopes, provide a fast screen
refresh rate of 60 times/second,
regardless of the number of
waveforms displayed, and minimal
display blind time so you can
capture and display infrequent
events that other scopes might miss.
H
• 60/100/150/500 MHz bandwidth
• Choice of: high sample rates,
4 channels, deep memory, or color
display models
• Real-time vector display
• Automatic measurements
• Pre-trigger viewing, trace storage
• Optional remote control/hard copy
Powerful digital features
The digital architecture of
HP 54600-series oscilloscopes gives
you a multitude of features that
help you get your job done easier
and faster:
• Pre-trigger viewing capability lets
you view events that you’d miss
with an analog scope. This
feature lets you see what
happened before the trigger
event, so you can troubleshoot
more effectively.
• Autoscale frees you from
resetting the scope every time
you move the probe from test
point to test point. You simply hit
the autoscale button and it sets
voltage, time and trigger
parameters for you.
• With autostore, the waveform
displays at full brightness while
all previously acquired
waveforms remain on the scope’s
screen at half brightness. This lets
you see a history of waveform
activity while simultaneously
viewing the live waveform. You
can use this tool to analyze worstcase jitter and noise, or to
permanently capture infrequent
waveform anomalies.
• Automatic measurements of
voltage, frequency and time, plus
user-defined cursor
measurements, make waveform
characterization fast and easy.
• With peak detect, you won’t have
to worry about missing narrow
glitches.
Choose from models designed
to meet your needs
The HP 54600 series includes eight
models designed to meet your
needs and your budget.
HP 54600B 100 MHz oscilloscope
With 100 MHz bandwidth, two input
channels and sweep speeds from
2ns/div to 5 s/div, the HP 54600B is
ideal for production, test, field
service and education, or anywhere
you need a solid, dependable scope.
HP 54645A MegaZoom
oscilloscope
The HP 54645A oscilloscope brings
the advantages of deep memory
with none of the disadvantages
usually associated with this class of
oscilloscopes. The HP 54645A is a
dual-channel 100 MHz oscilloscope
with 200 MSa/s and a full 1 MB of
memory behind each of its
channels. Through the application
of MegaZoom technology, this deep
memory oscilloscope has a high
speed/low dead time display and a
highly responsive front panel.
Unlike all other deep memory
2
scopes which force the user to
choose between fast response and
deep memory, the MegaZoom
technology gives you a scope that is
always fast and deep. Pan and zoom
operation is as simple as turning the
time/division knob. No special
menus or controls are required to
take full advantage of the HP
54645A’s deep memory.
A powerful glitch trigger extends
the power of the MegaZoom
technology in solving your toughest
troubleshooting problems. Simply
set-up the desired pulse width that
represents a worse case situation
and after the scope finds it, pan and
zoom through the deep waveform
record to find out exactly what was
going on in your circuit that caused
the problem.
HP 54602B 4-channel oscilloscope
When you need more bandwidth
than the HP 54600B and HP 54645A
provide, take a closer look at the
HP 54602B scope. You get the same
capabilities as with the HP 54600B
but with the added advantage of a
150 MHz bandwidth, 4 (2+2)
channels and 1mV/div sensitivity.
HP 54603B 60 MHz oscilloscope
For colleges and universities with
tight budgets, this scope is a great
way to introduce students to the
world of professional test
equipment. Students can use the
60 MHz , 2-channel HP 54603B to
understand circuit operation and
learn standard measurement
practices on the same type of
equipment they are likely to use
when they graduate. Sweep speed
varies from 5 ns/div to 5s/div.
HP 54610B 500 MHz oscilloscope
Even though the HP 54610B is the
least expensive 500 MHz
oscilloscope on the market, it has
analog performance that is similar
to higher cost oscilloscopes. The
HP 54610B is ideal for many
production line test applications.
This 2-channel, delayed sweep
scope offers a viewable external
trigger and horizontal accuracy of
+0.001%. Sweep speeds range from
1ns/div to 5s/div.
HP 54615B 1 GSa/s oscilloscope
With the HP 54615B you can capture
narrow glitches and subtle details of
your signal. This 2-channel scope
combines 500 MHz bandwidth,
1 GSa/s sample rate and 1 nanosecond
peak detection on both channels.
The HP 54615B peak detection
allows the scope to maintain a 1 GSa/s
sample rate at all sweep speeds. A
horizontal accuracy of 0.005%
means you can make critical timing
measurements with confidence.
HP 54616B 2 GSa/s oscilloscope
The top-of-the line HP 54616B
offers the same benefits as the
54615B but with twice the sample
rate—2GSa/s sampling rate, 500
MHz bandwidth and 1 nanosecond
peak detection. Whether you need
to verify a one time, 1 ns edge or
view the envelope of a modulated
waveform, the HP 54616B has the
power and flexibility to get the job
done. And, the intuitive front panel
and responsive display makes this
the scope of choice for everyday
troubleshooting.
HP 54616C color oscilloscope
The HP 54616C color display makes
viewing more interesting and easier
when you are viewing multiple
waveforms.
3-year warranty
All HP 54600-series oscilloscopes
include a full 3-year warranty with
optional 5-year warranty coverage.
Each scope includes two 1.5 meter
10X voltage probes, a user’s guide,
and a power cord.
Technical Specifications
HP 54600B, HP 54602B, HP 54603B, HP 54610B, HP 54615B, HP 54645A and HP 54616B/C Oscilloscopes
HP 54603BHP 54600BHP 54645AHP 54602BHP 54610B HP 54615B/16B/16C
CH 1 & 2dc, ac or grounddc, ac or grounddc, ac or grounddc, ac or grounddc, ac or grounddc, ac or ground
CH 3 & 4NANANAdc, groundNANA
Maximum input (dc + peak ac)400 V400 V400 V400 V250 V or 5 Vrms250 V or 5 Vrms
or 50 Ω selectableor 50 Ω selectable
in 50 Ω modein 50 Ω mode
Timebase range (main & delayed) 5 s/div to 5 ns/div5 s/div to 2 ns/div50 s/div to 2 ns/div5 s/div to 2 ns/div5 s/div to 1 ns/div5 s/div to 1 ns/div
Trigger sourcesCH 1, 2, line, or ext.CH 1, 2, line, or ext.CH 1, 2, line, or ext.CH 1, 2, 3, 4, or lineCH 1, 2, line, or ext.CH 1, 2, line, or ext.
Horizontal accuracy±0.01%±0.01%±0.01%±0.01%±0.01%±0.005%
Horizontal resolution100 ps100 ps40 ps100 ps100 ps20 ps
Trigger sensitivity
dc to 25 MHz0.35 div or 3.5 mV0.35 div or 3.5 mV0.35 div or 3.5 mV0.35 div or 0.7 mV0.5 div or 2.5 mV*** 0.5 div or 3.5 mV***
dc to max. bandwidth1 div or 10 mV1 div or 10 mV1 div or 10 mV1 div or 2 mV**1 div or 5 mV
Record length (maximum)4,000 points4,000 points1M points4,000 points4,000 points5,000 points
single shot2,000 points2,000 points1M points2,000 points2,000 points5,000 points
Max. display update rate1,500,000 points/sec 1,500,000 points/sec 3,000,000 points/sec1,500,000 points/sec 1,500,000 points/sec 500,000 points/sec
Resolution8 bits
PowerVoltage: 100–240 Vac, 48–440 Hz, 300 VA maximum
Net weightApprox. 6.2 kg (14 lbs)
Size (excl. handle)172 mm H x 322 mm W x 317 mm D (6.8 x 12.7 x 12.5 in)
Warranty3 years
†
HP 54616B 500 MHz
1 div or 7 mV
†
HP 54616 2 GSa/s
* Maximum bandwidth on CH 1 & 2 is 100 MHz at 1, 2, and 5 mV/div.
** HP 54602B, for ranges 1, 2, and 5 mV/div, sensitivity between 25 MHz and
100 MHz on CH 1 & 2 is 2 div or 4 mV.
*** Trigger sensitivity from dc to 100 MHz.
†
Trigger sensitivity from 100 MHz to max. bandwidth.
††
Maximum bandwidth on CH 1 & 2 is 75 MHz at 1, 2 and 5 mV/div.
3
Vertical System(HP 54600B, 54645A,
54602B, 54603B)
Bandwidth Limit≈ 20 MHz
InversionCH 1 & CH 2
CMRR≈ 20 dB at 50 MHz
Dynamic Range±8 div from center screen
Input R&C1 MΩ , ≈ 13 pf
Maximum Input400 V (dc + peak ac)
Math FunctionsCH 1 + or – CH 2
Cursor Accuracy [1][2]
Single CursorVert. Acc. ± 1.2% of full
scale, ± 0.5% of position
value
Dual CursorVert. Acc. ±0.4%
of full scale
Vertical System(HP 54610B, 54615B,
54616B/C)
Bandwidth Limit≈ 30 MHz
InversionCH 1 & CH 2
CMRR≈ 20dB at 50 MHz
Dynamic Range±12 div from center screen
Input R&C1 MΩ, ≈ 9 pf or 50Ω
selectable
Maximum Input250 V (dc + peak ac) or
5 Vrms in 50Ω mode
50ΩProtectionProtects 50Ω load from
excessive voltage
Time SkewAdjustable over a range of
±25ns to remove effects of
cabling
Probe SenseAutomatic readout of 1X,
10X, 20X, 50X and 100X
probes
Math FunctionsCH 1 + or – CH 2
Cursor Accuracy [1][2]
Single CursorVert. Acc. ± 1.2% of full
scale, ± 0.5% of position
value
Dual CursorVert. Acc. ±0.4%
of full scale
Horizontal System
Cursor Accuracy ± 0.01% ± 0.2% of full
(∆t & 1/∆t) [3]scale ±200 ps
Delay Jitter10 ppm
Pretrigger Delay≥10 div
(Negative time)
Posttrigger Delayat least 2,560 div or
(Trigger to start 50 ms. Not to exceed
of sweep)100 s.
1 ppm (54615B, 54616B/C)
Delayed Sweep
Main SweepDelayed Sweep
5 s/div to 10 ms/divup to 200X main
5 ms/div and fasterup to 2 ns/div
54610B, 15B/16B/16C up to 1ns/div
Trigger System
Couplingac, dc, LF reject, HF reject,
ModesAuto, Autolevel, Normal,
HP 54645A Glitch
triggering
TV TriggeringTV line and field. 0.5 div of
TV Functions
Line CountingDelay time calibrated in
All Field TriggerOscilloscope triggers on the
(both fields selected,
54602B and 54610B)
HoldoffAdjustable from 200 ns
External Trigger (54600B, 54603B, 54645A)
Range Sensitivity±18V
Couplingdc, HF reject and noise
Input R&C1MΩ, ≈ 13pf
Maximum Input400 V (dc + peak ac)
& noise reject.
LF & HF: -3db at ≈ 50 kHz
Single, & TV
Minimum width 8 ns,
Operators: <, >, or range
composite sync for stable
display (Ch1 & Ch2)
NTSC and PAL line numbers
vertical sync pulse in both
fields, allowing use with
noninterlaced video.
to ≈ 13 s
dc to 25MHz: <50mV
dc to 100 MHz: <100mV
reject
External Trigger (54610B, 54615B, 54616B/C)
Range Sensitivity±18V
dc to 100MHz: <75mV
dc to 500 MHz: <150mV
Couplingdc and ground
Input R&C1MΩ, ≈ 12pf or 50Ω
selectable
Maximum Input250 V (dc + peak ac) or
5 Vrms in 50Ω mode
Trigger ViewExternal trigger is viewable.
(HP 54610B only)Bandwidth is >350MHz
X-Y Operation
Z-BlankingTTL high blanks trace
(not available on 54615B,
54616B/C)
BandwidthX & Y same as vertical
system
Phase Difference± 3 degrees at 100 kHz
± 3 degrees at 10 MHz
(54615B, 54616B/C)
Display System
Display7-inch Raster CRT
Resolution255 vertical by 500
horizontal points
ControlsFront-panel intensity control
Graticule8 X 10 grid or frame
AutostoreAutostore saves previous
sweeps in half bright
display and the most recent
sweep in full bright display.
Display (54616C)5.8 inch Active Matrix Color
LCD Display
[1] Temperature ± 10°C from calibration
[2] Use full scale at 80mV for 2mV/div and 5 mV/div ranges
[3] Use full scale of 50 ns for 2 ns/div
4
Acquisition System
Simultaneous Channels
HP 54600B/54610B,Channels 1& 2
54615B, 54616B
HP 54602BChannels 1& 2 or 3& 4
Record Length4,000 points Vectors off
HP 54615B, 54616B/C 5,000 points
HP 54645A1 million points
Max Update RateVectors off: 1,500,000
HP 54615B, 54616B/C 500,000 points/sec
HP 54645A3,000,000 points/sec
Usable Single-Shot2 MHz, single channel
Bandwidth
HP 54615B250 MHz
HP 54616B/C500 MHz
HP 54645A20 MHz
Peak Detect50 ns glitch capture (100 ns
HP 54615B, 54616B/C 1 ns glitch capture
HP 54645A5 ns
Average Number of averages
and/or Vectors on
points/sec
Vectors on: 60 full
screens/sec, independent of
number of waveforms being
displayed
1 MHz, dual channel
dual channel) at sweep
speeds of 50 µs/div and
greater
Line Voltage Range100 Vac to 240 Vac
Line Voltage Selection Automatic
Line Frequency45 Hz to 440 Hz
Max Power220 VA
Consumption300 VA (54615B, 54616B/C)
Environmental The instrument meets
Characteristics
Ambient Temperature
Operating –10 °C to +55 °C
Nonoperating–51 °C to + 71 °C
Humidity [1]
Operating95% RH at 40°C for 24 Hrs
Nonoperating90% RH at 65°C for 24 Hrs
Altitude
Operatingto 4,500 m (15,000 ft)
Nonoperating to 15,000 m (50,000 ft)
EMI (Commercial)Meets FTZ 1046 Class B
EMI (MIL-T-28800D) Meets requirements in
CE01,CE03 Full limits
CS01, CS02, CS06 Full limits
RE01 15 dB relaxation to 20 kHz;
RE02 (With Opt 002)Full limits of class A1c and
(Without Opt 002) 10 dB relaxation from
RS02Exceptioned
RS03 (With Opt 001) Slight trace shift from
VibrationOperating: 15 minutes along
ShockOperating: 30 g, 1/2 sine,
Size (excluding handle)
Weight6.2 kg (14 lbs)
SafetyCSA Certification,
Warranty3 years
the requirements of MIL-T28800D for Type III, Class 3,
Style D equipment as
described below.
accordance with Paragraph
3.8.3, EMI Type III, and MILSTD-461C as modified by
Table XII.
exceptioned from 20 kHz to
50 kHz
A1f
14 kHz to 100 kHz
80 MHz to 200 MHz
each of the 3 major axes;
0.025 inch p-p displacement,
10 Hz to 55 Hz in one-minute
cycles. Held for 10 minutes
at 55 Hz (4 g at 55 Hz).
11 ms duration, 3 shocks
per axis along major axis.
Total of 18 shocks
Height: 172 mm (6.8 in)
Width: 322 mm(12.7 in)
Depth: 317 mm (12.5 in)
IEC 348
UL 1244 listed
Expandable feature set to meet
your changing needs
HP 54600-series oscilloscopes can be
easily and inexpensively upgraded
with add-on modules and software
links to provide advanced analysis
capability. Accessories and modules
available include:
• Interface modules for remote
control and hard-copy output to
RS-232, HP-IB and parallel printers
and plotters. With the addition of
these modules, the scope’s two
trace memories become
nonvolatile.
• Add FFT capability and unattended
signal monitoring along with the
rest of the basic interface module
benefits. Catching intermittent
failures is easy with unattended
waveform monitoring. The
nonvolatile memory can store up
to 100 traces.
• HP BenchLink Scope software for
transferring screen images and
waveform data to Windows
applications for further analysis or
to create polished reports and
presentations. HP BenchLink
Scope also lets you store
instrument setups.
Enhanced TV/video trigger
With Option 005, six of the
HP 54600-series scopes gain the
ability to trigger and perform highly
detailed measurements on the video
components of your system. You can
order this option for HP 54602B,
HP 54610B, HP 54615B, HP 54616B/C,
and HP 54645A oscilloscopes. For
more information about this option,
request data sheet 5965-1100 EN.
5
HP 54650A HP-IB Interface Module
Provides full remote control and hard copy to HP-IB
printers and plotters. Programming is in accordance
with IEEE 488.2. With the addition of this module,
the scope’s two pixel memories become non-volatile.
An operating and programming manual and a
programming examples disk are supplied.
SpecificationsThe interface capabilities of
the HP 54600 series
oscilloscope with this
module installed are as
defined by IEEE 488.1 as
SH1, AH1, T5, L4, SR1, RL1,
PP1, DC1, DT1, C0 and E2.
Printer/Plotter HP ThinkJet, HP QuietJet,
SupportedHP PaintJet, and HP LaserJet;
HP-GL compatible plotters.
HP 54652B RS-232/Parallel Interface
Module
Provides full remote control via RS-232 and printing
via parallel in one module. The RS-232 can also be
configured for printing when not being used for
remote control.
Specifications
Connector Type9 pin (m) DTEPort, works
with HP 34398A RS-232
cable.
ProtocolsXon/Xoff, hardwire
Data Bits8
ParityNone
Baud Rates1200, 2400, 9600, or 19200
Printer/Plotter HP ThinkJet, HP QuietJet,
SupportHP PaintJet, and HP LaserJet;
HP-GL compatible plotters.
Specifications
Connector Type25 pin (F) connector, works
with HP C2950A parallel
printer cable.
Supported Printers: Epson FX-80 or HP PCL
compatible printers.
HP 54657A and 54659B Measurement/
Storage Modules
With the the addition of either the HP 54657A
module with HP-IB interface or the HP 54659B
module with RS-232 and parallel interface, the HP
54600 series oscilloscope will provide all of the
following features.
19 Automatic Measurements consisting of:
VoltageVamp, Vavg, Vrms, Vpp,
Vpre, Vovr, Vtop, Vbase,
Vmin, and Vmax
TimeDelay, Duty Cycle,
Frequency, Period, Phase
Angle, Rise Time, Fall Time,
+ width, and - width
ThresholdsUser selectable among
10%/90%, 20%/80%, or
absolute voltage levels.
Cursor Readout Voltage or percentage
ModesTime or phase angle
Waveform Math Functions
Function 1Addition, subtraction, and
Function 2Differentiation, integration,
FFT
WindowsExponential, flat top,
Samples1024 points
Trace Memoryup to 100 nonvolatile
Memories 1 – 3High speed storage without
Memories 4 – 100Storage with compression.
Memory LabelingAn onscreen text editor is
Real Time Clock24-hour format with battery
Unattended Waveform
Monitoring
Testing MethodComparison to waveform
Number of Masks2
Mask Generation Automask, controlled from
and Operation
multiplication
and FFT
Hanning and rectangular
memories
compression.
Storage time is approxi-
mately 7 seconds. Number
of traces that can be stored
is a function of complexity,
with the minimum being 4
highly complex traces and
the maximum being 96.
provided for creating labels
up to 20 characters. Each
label contains the date and
time it was saved.
back-up. Can be set from
front panel.
mask.
the front panel, generates
mask from displayed
waveform with selectable
tolerance. Mask editor
function allows pixel-bypixel editing and line
drawing. Smoothing
function performs a running
average of 3 pixels.
Action on Failure• Save failed trace to
Hard Copy andHP 54657A HP-IB
Programmability(For HP-IB specifications
Interfacesee HP 54650A)
memory with date and time
of the failure
• Print failed trace with
date and time of the failure
• Count the failure and
maintain pass/fail statistics
while continuing the test
HP 54658A RS-232
(For RS-232 specifications
see HP 54652B)
6
10442A fine pitch probe10070A rugged probe
Specifications for HP 54600-Series Scope Probes
ProbeBandwidthDivisionApprox.InputApprox.Rise-MaxScope
ModelRatiolengthRInputtimeinputCompatibility
NumberCdc + peak ac
This accessory adapts this
series of rugged probes to
HP logic analyzer style
grabbers that can be
used in SMT probing
applications. Supplied with
8 grabbers.
HP 5081-7705BNCAdapter for
HP 1007X probes
This accessory clips on the
end of the probe and allows
the probe to mate with
BNC (f) connectors.
HP 5081-7690Replacement Accessory
Kit for HP 1007X probes
This kit contains
replacement Hook Tip,
IC Tip, Ground Bayonet,
Ground Lead, Adjustment
Tool, and Probe
Identification Tags.
Additional Measurement Accessories
HP 10100C50 Ω±1% Feedthrough
Termination
BNC (f) to BNC (m),
Frequency range dc-300
MHz, Max. VSWR 1.1:1
HP 11094B75 Ω ± 0.2% Feedthrough
Termination
BNC (f) to BNC (m),
maximum power 1 Watt
HP 1251-2277Dual Banana(m) to BNC (f)
Adapter
HP 10110BDual Banana(m) to BNC (m)
Adapter
Additional Accessories
HP 10098AFront Panel Cover and
Pouch Kit
This kit will add the
Option 101 front panel
cover and pouch to any
54600-series oscilloscope
HP 1183ATestmobile Scope
Cart for HP 54600-series
scopes
7
Ordering Information
HP 54600-Series Oscilloscopes
HP 54600B Two-channel, 100 MHz Oscilloscope
HP 54602B Four-channel, 150 MHz Oscilloscope
HP 54603B Two-channel, 60 MHz Oscilloscope
Each of the above oscilloscopes comes with two 1.5 meter 10X
probes (HP 10071A), a user’s and service guide, and power cord.
HP 54610B Two-channel, 500 MHz, 20 MSa/s Oscilloscope
HP 54615B Two-channel, 500 MHz, 1 GSa/s Oscilloscope
HP 54616B Two-channel, 500 MHz, 2 GSa/s Oscilloscope
HP 54616C Color two-channel, 500 MHz, 2 GSa/s Oscilloscope
HP 54645A Two-channel, 100 MHz, 200 MSa/s Oscilloscope
Each of the above oscilloscopes comes with two 1.5 meter 10X
probes (HP 10073A), a user’s and service guide, and power cord.
Options
Opt. 001 RS-03 Magnetic interface shielding added to CR
Opt. 002 RE-02 Display shield added to CRT to reduce radiated interface
Opt. 005 Enhanced TV/video triggering (not HP 54600B/03B)
Opt. 090 Delete probes (for HP 54600/02/03B)
Opt. 090 Delete probes (for HP 54610B, 54615B, 54616B/C)
Opt. 101 Accessory pouch and front panel cover (HP 10098A)
Opt. 102 Two additional HP 10071A probes (HP 54602B only)
Opt. 103 Operator training kit (includes training signal board & lab workbook)
Opt. 104 Carrying case (protects scope for shipping or baggage checking)
Opt. 106 HP BenchLink Scope software for Windows (HP 34810B)
Opt. 1CM Rack Mount Kit (P/N 5062-7345)
Opt. W50 Additional 2-year warranty (5-year total), starting at
Manual options (please specify one)
ABA US EnglishABF FrenchABJ Japanese
ABD GermanABZ ItalianAB1 Korean
ABE SpanishABO Taiwan Chinese
HP 54650-series enhancement modules
HP 54650A HP-IB interface module
HP 54652A Parallel interface module
HP 54652B RS-232 and parallel interface module
HP 54655A HP-IB test automation module (compatible only with 54600/03/02/10B)
HP 54656A RS-232 test automation module (compatible only with 54600/03/02/10B)
HP 54657A HP-IB measurement/storage module
HP 54659B RS-232 and parallel measurement/storage module
Each module includes user’s and programmer’s guides; HP 54656A
includes HP 98561-61604 RS-232 adapter cable and one 2-meter RJ-45 cable.
Modules with product numbers ending in “A” are compatible with HP 54600A-series and HP 54600B-series scopes. Modules ending
in “B” are compatible with the HP54600-B-series only. The HP 54620A logic analyzer can use any of these modules, but it uses the
modules for I/O only.
Additional oscilloscope accessories, probes and terminations
HP 10070A 1:1 probe
HP 10071A 10:1 probe
HP 10072A SMT probing adapters
HP 10073A 10:1 500 MHz probe with readout
HP 10074A 10:1 150 MHz probe with readout
HP 10442A 10:1 GHz probe for 50 Ω inputs.
HP 10444A 10:1 500 MHz mini-probe with readout
HP 1137A 1000:1 high-voltage probe
HP 10100C 50 Ω feedthrough termination
HP 5081-7690 HP 1007X probe accessory kit
HP 5081-7705 HP 1007X probe-to-BNC (m) adapter
HP 10098A Front panel cover and pouch kit
HP 34327A Inverter, 12 Volt dc to 115 V ac
HP 34810-Series BenchLink Software
HP 34810B BenchLink Scope Software
Includes software on 3.5” disk, user’s guide. (all languages)
HP-IB or RS-232 module needed for connection to scope.
For more information on
Hewlett-Packard Test and
Measurement products, applications
or services please call your local
Hewlett-Packard sales offices. A
current listing is available via the
Web through AccessHP at
http://www.hp.com. If you do not
have access to the internet, please
contact one of the HP centers below
and they will direct you to your
nearest HP representative.
United States:
Hewlett-Packard Company
Test and Measurement Organization
23 Inverness Way East
Englewood, CO 80112
1 800 452 4844