Agilent Technologies
54620C Color 16
Channel Logic
Analyzer
Data Sheet
Product Specifications
Record length:
2K for sample period >= 8 ns
(sweep speeds of 1us/div to
1 s/div with auto glith enabled)
8K for sample periods of 4 and 2 ns
(sweep speeds of 500 ns/div and faster and
all sweep speeds with auto glitch enabled)
Glitch detect:
Automatically activated when sampling period
is slowed to < 4 ns (1 us/div and slower).
Minimum detectable glitch: 3.5 ns
Setup functions
Autoscale, 16 saved setups, two trace memories,
channel labeler (with 75 preset and user defined labels)
TIMEBASE specs
Timebase range: 1 s/div to 5 ns/div (main & delayed)
Timebase accuracy: 0.01% of reading
Timebase cursor accuracy:
Single channel: ±(sample period + 0.01% of reading
+ 0.2% of screen width)
Dual channel: ±(sample period + 0.01% of reading
+ ch-ch skew + 0.2% of screen width)
Maximum sample rate: 500 MSa/sec
TRIGGER specs

Trigger sources: All channels and external
Auto/normal operation
Auto-trigger: Free-running display if trigger not found
Normal: Analyzer will wait indefinitely for trigger
Modes
Edge, pattern, advanced (2 pattern and edge terms).
Advanced operators: Or, Then, Entered, Exited, Duration
> time, Occurs N times
ENVIRONMENTAL specs
Interface
Compatible with Agilent 54650A, Agilent 54651A, and Agilent 54652B
interface modules, and Agilent 34810A BenchLink/Scope software
Net Weight 6.8 kg (15 lbs)
Size 172.7 mm H X 322.6 mm W X 317.5 mm D
(6.8 X 12.7 X 12.5 in)
Warranty 3 year