Thank you for choosing the Compact 60
sional, powerful and compact amplier system for acoustic instruments in superb quality with AER‘s typical authentic, transparent and
self-asserting sound performance. Two channels make it possible
to operate a microphone and an instrument independently of each
other. The dynamically controlled power amplier and the broadsprectrum loudspeaker system guarantee distortion-free reproduction even at high volumes.
We wish you hours of happy playing with your Compact 60
2
2. You have chosen a profes-
2!
Page 3
2. Safety Precautions
inp ut
C
Compact 60
2
input
clipclipselectpower
line
mic
high
low
colour
channel 1channel 2
gaingainbass
effect
eff. panreturnmaster
treblebassmiddletreble
The following guidelines shall help minimize the risk of injury through
re or electric shock.
1. Carefully read these safety notes before you use the device!
2. Keep these safety notes in a safe place.
3. Pay attention to all warnings, instructions and additional texts on
the unit.
4. Do not install or use your amp in close proximity to water or if you
are wet yourself.
5. Use your amp in a safe place where nobody can step on cables or
trip over and damage them.
6. Pay attention to an unhindered air circulation around the amp, never obstruct the air vents or grilles.
7. Always pull the mains plug before cleaning your amp. Use only a
dry cloth for cleaning. Avoid the use of detergents and do not let
any liquids seep into the unit.
3. Controls and Connections
8. Use only the right fuses with the same current rating and trigger
characteristic as replacements. Never mend fuses! Pull the mains
plug before replacing a fuse. Should a fuse blow again after a
short while, the device needs to be checked.
9. Never install your amp close to devices with strong electromagnetic elds such as large mains transformers, revolving
machines, neon illumination etc. Do not lay signal cables parallel
to power current cables.
10. There are no user-servicable components inside the unit. To avoid the risk of an electric shock, the unit must not be opened. All
maintenance, adjustment and repair works should be carried out
by qualied sta only. Any unauthorized tampering will void the
2-year warranty.
11. In keeping with the EMV regulations screened cables with correctly tted connectors must be used for all signal connections.
12. Always use an earthed power supply with the correct mains voltage. If you are in doubt about the power outlet‘s ground, have it
checked by a qualied technician.
13. Cable up your amp only when it is powered o.
Front panel top (from left to right):
channel 1
input 6.3 mm stereo jack socket
high/low Input sensitivity selector switch
pressed = lower sensitivity
clip This indicator lights up when overload is imminent in
the respective channel.
gain Input level control
colour This switch activates the midrange contour lter.
Boosts presence and slightly cuts midrange
frequencies.
bass Bass control
middle Midrange control
treble
Treble control
channel 2
input XLR/6.3 mm jack plug combi socket
line/mic Signal source selector switch.
line: For instruments (pickups), only via jack plug.
mic: For microphones with a jack or an
XLR connector.
clip This indicator lights up when overload is imminent in
the respective channel.
gain Input level control
bass Bass control
treble
Treble control
e. pan panorama control to distribute the eects between
the channels.
left: internal eect on channel 1 & external
eect on channel 2
mid: internal & external eect on channel 1
and channel 2
right: internal eect on channel 2 & external
eect on channel 1
select push button for selection of four eects, indicated by
the LEDs between return and master.
return level control for the internal eects
power This LED indicates that your amplier is ready to use
master Adjusts the overall volume level
3
Page 4
Back panel (from left to right):
Compact 602
twin channel acoustic amplifier
phonesOutput for a stereo headphone set.
6.3 mm stereo jack socket.
Never use mono jack plugs,
otherwise the amp could be damaged!
tuner Output to an external tuner. 6.3 mm mono jack socket.
line out preamplier output after the master control.
6.3 mm mono jack socket.
DI-outBalanced preamp output, pre master, post EQ, with return and eects. XLR socket
sendOutput to the input of an external eects unit.
6.3 mm mono jack socket.
returnInput for the output signals of an external eects processor. 6.3 mm mono jack socket.
footswitch connection to a double footswitch to switch internal
and external eect on and o.
(Tip = internal Eect, Ring = external Eect on/o ).
6.3 mm stereo jack socket.
poweron Combined power switch with fuse holder and IEC
mains socket
4
Page 5
4. Operation Summary
• Cabling and startup
Check if your local mains voltage (e.g. 120 V in the USA, 230 V in Europe) complies with the required operating voltage for your amplier.
The proper mains voltage is printed on the rating plate on the rear
panel of the unit, e.g. AC 230V (AC means alternating current).
Please take care that the master, return and all gain controls are
set to zero (left stop) and all other controls to their center positions.
The pushbuttons should be switched o (not pressed).
Then make all the necessary cable connections
(mains, instrument etc.).
Now you may turn on your amplier with the power on switch located on the rear. The green power control LED will indicate operational
readiness.
• Level adjustment
Using the gain controls, high/low and line/mic switches you can adapt the amplier to your signal sources (guitar pickups, microphone
etc.) to achieve the best possible signal-to-noise ratio (SNR).
First adjust the line/mic switch according to your signal source: mic is
suitable for microphones, line for pickups and other signal sources.
Turn the gain control clockwise until the red clip indicator ashes
momentarily when playing with a strong attack. Now lower the gain
control (and also the instrument‘s volume control) again slightly to
get some headroom for an undistorted reproduction. The clip control
LED should now only rarely ash. In case you nd the level setting
dicult because the input signal is too strong, press the high/low
switch as well. If the input signal is too weak, the gain control must be
increased accordingly. With signal sources with a sucient input signal strength the gain control should be adjusted between the ‘ 9:00
and 11:00 o‘clock‘ position. Finally set the desired overall volume level
with the master control.
• Equalization
The three-band equalizer with individual bass, middle and treble
2
control of your Compact 60
both complies with the special requirements of acoustic instruments
has been designed in such a way that it
and also with the more general demands of other sources. The colour
switch activates a midrange contour lter which is especially useful
for picking techniques.
One more note: Adjusting the EQ controls can also aect the level
setting. Whenever you see the clip indicator ashing frequently, you
should slighty correct your gain setting (see ‚Level adjustment‘).
• Eects
2
The Compact 60
return control determines the intensity of the internal eects (left
has a built-in (internal) digital eect processor. The
stop = no eect). Furthermore an additional eects unit (external effect) may be connected. For this purpose please use the send and
return sockets located on the back of the amplier (send goes to Input, return is connected to the output of the external eects device).
The intensity is then adjusted at the external eects unit. The external
eects loop works in ‚parallel‘ mode, i.e. the eect signal is blended
with the original signal.
A standard double footswitch can be connected to the footswitch
socket on the rear of the amp with a stereo cable. This switch can be
used to turn the internal and external eects on and o.
We wish you hours of happy playing with your Compact 60
2!
5
Page 6
5. Technical Data
Inputs
Input (channel 1) Stereo jack ¼” (6.35 mm)
High impedance, unbalanced jack input for
instruments (pick-ups) and line-level sources.
high/low switch: –10 dB attenuator
Impedance: 2.2 Meg
Input (channel 2) Combo socket, XLR jack ¼” (6.35 mm)
line mode:High impedance, unbalanced jack input for
instruments (pick-ups) and line-level sources.
Sensitivity: 38 mV
Impedance: 1 Meg
mic mode: XLR (balanced), stereo jack (balanced),
or mono jack (unbalanced) input.
Voice Filter
24 V-Phantom-Power through 6.8 kohms
to XLR socket
Clip indicator: Headroom 6 dB
Return Return from external parallel eect loop
Sensitivity: 430 mV
ClipHeadroom: 15 dB
Attack Time: 4 ms
Outputs (note 3)
Phones Headphones output. When connected, internal
speakers are muted.
Stereo jack, ¼” (6.35 mm)
Output power: 100 mW
Caution: For stereo headphones with stereo jack
plug only. Do not connect mono plugs.
Specications and appearance subject to change without notice.
6
Page 7
LINE
MIC
MIC
LINE
Option
GAIN
COLOURMIDDLE
OFF/ON
SUBSONICLIMITER
POWER AMP
FX
DUAL CONE SPEAKER
TUNER
TREBLEBASS
BASSTREBLE
CLIP
Clip detect
CLIP
Clip detect
SEND
EFF. RETURN
MASTER
SELECT
LINE
F/S
RETURN
PHONES
DI
GAIN
PREAMP
VOICE
PREAMP
EFFECT PAN
TR
+15V
PAD
CH 1
+24V
TR
CH 2
1
2
3
1
2
3
6. Block Diagram
7
Page 8
7. Eects Table
Nummer Bezeichnung Art
LED Description Type
01 warm hall reverb
02 bright hall reverb
03 chorus with reverb chorus/reverb
04 anging anger
8. Manufacturer‘s Declaration
The disposal of electronic equipment in household waste is not permitted. AER GmbH waste electrical and electronic equipment is not
to be taken to public collection points for disposal.
AER GmbH remains solely responsible for the disposal of AER GmbH
waste electrical and electronic equipment labelled with a dustbin.
To dispose of AER GmbH waste electrical and electronic equipment
that is labelled with a dustbin symbol, please contact us; we will
ensure correct and cost-neutral disposal.
In the case of AER GmbH waste electrical and electronic equipment
that is not labelled with a dustbin, the owner is responsible for correct disposal in accordance with the law.
However, we are also happy to help in this case and we can present
you with the options of where to dispose of these electrical goods.
The telephone number of AER GmbH: +49 (0)2361 891789
Here, we will provide you with qualied information on the disposal
of AER GmbH waste electrical and electronic equipment.
Declaration
The EU directive on the disposal of waste electrical and electronic
equipment (WEEE, 2002/96/EC) has been changed to the electrical
and electronic equipment act.
All AER electrical equipment aected by WEEE has been labelled
with the symbol of a crossed out dustbin since 13.08.2005.
This symbol indicates that the disposal of the equipment is not permitted with household waste. It has been circulated in this form
since 13.08.2005.
In the German registration department EAR, AER GmbH has been
registered under WEEE registration number DE26301529.
European Union, Norway, Iceland
and Lichtenstein
The disposal of electronic equipment in
household waste is not permitted.
All AER electrical equipment aected by WEEE has been labelled with
the symbol of a crossed out dustbin since 13.08.2005. This is also applicable for Norway, Iceland and Liechtenstein.
This symbol indicates that the disposal of the equipment is not permitted with household waste.
It has been circulated in this form since 13.08.2005.
The European directives of WEEE are anchored in dierent respective national laws in all European states. As such, we are unfortunately
unable to provide you with one standard disposal solution.
The distributor or importer for the respective state is responsible for
the observance of the laws of that state and must ensure the disposal
of the waste electrical and electronic equipment in accordance with
national regulations.
Other Countries
For correct disposal of the electrical goods, please ask the local dealer
or the appropriate authority.
www.aer-amps.com 20090701
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.