Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Thank you for purchasing an AEMC® Digital Flexbprobe.
For best results and for your safety, read the enclosed operating
instructions carefully and comply with the precautions for use.
PRECAUTIONS BEFORE USE
This instrument is protected against voltages of not more than
1000V with respect to ground in measurement CAT III or 600V in
CAT IV between the sensor and the conductor that measures the
current.
The protection provided by the instrument may be impaired if the
instrument is used other than as specified by the manufacturer.
•Do not exceed the rated maximum voltage and current or the
measurement category.
•Observe the conditions of use; temperature, relative humidity,
altitude, level of pollution, and location.
•Before each use, check the integrity of the insulation on the
sensor, cable and housing. Do not use the instrument if it is
open, damaged, poorly assembled, or if its accessories appear
damaged.
•The sensor must not be applied to or removed from uninsulated
conductors at dangerous voltages.
•Use personal protection equipment systematically.
•All troubleshooting and metrological checks must be
performed by competent and accredited personnel.
4
Digital Flexprobe® Models 400D & 4000D
1.1 International Electrical Symbols
Signifies that the instrument is protected by double or reinforced insulation.
CAUTION - Risk of Danger! Indicates a WARNING and that the operator must
refer to the user manual for instructions before operating the instrument in all
cases where this symbol is marked.
Must not be applied to or removed from bare conductors at dangerous voltages.
Type B current sensor as per IEC 61010‑2‑032.
Important instructions to read and understand completely.
Important information to acknowledge.
Battery.
Compliance with the Low Voltage & Electromagnetic Compatibility European
directives (73/23/CEE & 89/336/CEE).
In the European Union, this product is subject to a separate collection system
for recycling electrical and electronic components In accordance with directive
WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT IV:
CAT III:
CAT II: For measurements performed on circuits directly connected to
For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripple control units, or meters.
For measurements performed in the building installation at the
distribution level such as on hardwired equipment in fixed installation and circuit breakers.
the electrical distribution system. Examples are measurements
on household appliances or portable tools.
1.3 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If
the equipment appears to be damaged, file a claim immediately with the
carrier and notify your distributor at once, giving a detailed description of
any damage. Save the damaged packing container to substantiate your
claim.
Digital Flexprobe® Models 400D & 4000D
5
1.4 Ordering Information
Digital FlexProbe® (MiniFlex) Model 400D-6 w/6 ft Lead