No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval
or translation into any other language) without prior agreement and written consent from Chauvin Arnoux®, Inc., as
governed by United States and International copyright laws.
Chauvin Arnoux
15 Faraday Drive • Dover, NH 03820 USA
Tel: (800) 945-2362 or (603) 749-6434 • Fax: (603) 742-2346
This documentation is provided “as is,” without warranty of any kind, express, implied, or otherwise. Chauvin Arnoux
Inc. has made every reasonable eort to ensure that this documentation is accurate; but does not warrant the accuracy or
completeness of the text, graphics, or other information contained in this documentation. Chauvin Arnoux®, Inc. shall not
be liable for any damages, special, indirect, incidental, or inconsequential; including (but not limited to) physical, emotional
or monetary damages due to lost revenues or lost prots that may result from the use of this documentation, whether or
not the user of the documentation has been advised of the possibility of such damages.
Chauvin Arnoux®, Inc and AEMC® are registered trademarks of AEMC® Instruments.
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at .
Upon receiving your Megohmmeter Test Probe product package, ensure the
contents are consistent with the packing list. Notify your distributor of any missing
items.
If the equipment appears to be damaged, le a claim immediately with the carrier
and notify your distributor at once, providing a detailed description. Save the
damaged packing container to substantiate your claim.
1.2 Ordering Information
Megohmmeter Test Probe (600V CAT IV) .....................................Cat. #2155.75
Includes one 9V alkaline battery, user manual, and verication certicate.
Do not use the probe on an electrically live system.
The test probe plugs into:
■
■ MΩ terminal of the installation tester
You can hold the probe in one hand and the instrument in the other, and press
the probe’s yellow (TEST) button to take a measurement.
To use the remote probe:
1.Connect the probe to the instrument via the appropriate terminal. Then
2.Connect the red lead to the frame ground of the system under test. Then
terminal of the megohmmeter
connect the red safety lead supplied with the instrument to the + or
COM terminal, depending on instrument type. The symbol (for
megohmmeters) or (for installation testers) appears on the instrument
LCD.
touch the test probe measurement tip to the other side of the system (see
below).
In dark conditions, you can illuminate the measurement tip by pressing the
button on the back side of the probe.
The probe is powered by a 9V alkaline battery (type 6LF22). The nominal
operating voltage is between 7 and 10V.
The battery is needed only to power the light; the probe is otherwise fully
functional without the battery. Battery life is 100 hours of continuous operation.
3.2 Environmental
Indoor use
Operating range: 32 to 113°F (0 to 45°C) and 10 to 90% RH
Storage range (without battery): -40 to 158°F (-40 to 70°C) and 10 to 90% RH
Pollution Degree: 2
Altitude: <6562 ft (2000m)
3.3 Mechanical
Dimensions: (L x W x H): 6.1 x 1.85 x 1.93” (155 x 47 x 49mm)
Cord: 6.56 ft (2m)
Weight: approximately 7.76 oz (220g)
Ingress protection:
■ IP 53 according to IEC 60 529
■ IK 04 according to IEC 50102
Drop test: according to IEC 61010-1
3.4 Safety
Electrical safety according to IEC 61010-031 (Ed. 2 of 2002).
Use only factory specied replacement parts. AEMC® will not be held
responsible for any accident, incident, or malfunction following a
repair done other than by its service center or by an approved repair
center.
4.1 Cleaning
Disconnect all leads from the probe and turn it OFF.
Use a soft cloth, dampened with soapy water. Rinse with a damp cloth and
dry quickly with a dry cloth or forced air. Do not use alcohol, solvents, or
hydrocarbons.
4.2 Replacing the Battery
The battery must be replaced when the probe light is too dim to provide adequate
illumination.
1.Disconnect all leads and probes from the instrument.
2.Using a screwdriver, remove the two fastening screws.
3.Replace the old battery with a new one (9V alkaline battery, type 6LF22).
Used batteries must not be treated as ordinary household waste. Recycle
them appropriately.
4.Position the new battery in the designated slot, taking care to ensure correct
polarity
5.Close the case and ensure that it is closed completely and correctly.
The Megohmmeter Test Probe is warranted to the owner for a period of two
years from the date of original purchase against defects in manufacture. This
limited warranty
whom it was purchased. This warranty is void if the probe has been tampered
with or abused, or if the defect is related to service not performed by AEMC®
Instruments.
Full warranty coverage and product registration is available on our website at
Please print the online Warranty Coverage Information for your records.
What AEMC® Instruments will do:
If a malfunction occurs within the warranty period, you may return the probe to
us for repair, provided we have your warranty registration information on file or a
proof of purchase. AEMC® Instruments will, at its option, repair or replace the
faulty material.
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
is given by AEMC® Instruments, not by the distributor from
.
First, request a Customer Service Authorization Number (CSA#) by phone or by
fax from our Service Department (see address below), then return the instrument
along with the signed CSA Form. Please write the CSA# on the outside of the
shipping container. Return the instrument, postage or shipment pre-paid to:
Caution: To protect yourself against in-transit loss, we recommend you insure
your returned material.
NOTE: You must obtain a CSA# before returning any instrument.