AC Current Probe
Model MN03
Small and compact, the AC
Current Probe Model MN03 is
the ideal complement for any
multimeter to measure AC
currents in low-power secondary
or industrial applications.
When used with an AC voltmeter,
it allows you to directly read the
current measured on the
voltmeter.
Technical Assistance (800) 343-1391 www.aemc.com 1 of 4
Features
• Small, compact size
• Measurement range of 1 to 100A
• Jaw opening accommodates
conductors up to 0.39'' diameter
• Designed for DMMs, loggers,
recorders and oscilloscopes
• 40Hz to 10kHz response
a c /Aa c output signals
• 1mV
• Designed to EN 61010, 600V
CAT III safety standard
• DoubleInsulation
• CE Mark
Applications
• Measuring in breaker panels
a c
• Industrial loads
• HVAC
• Residential and commercial sites
• Data logging/recording
MN03_2129.18 (pdf) 0109 Rev.01
Specifications
MODEL MN03
ELECTRICAL
Range 100A
Measurement Range 1 to 100A
Accuracy in % ≤ 2% + 50mA
Phase Shift Not specified
Output Signal 1mV
(100mV at 100a)
Maximum Currents 1 < 150A permanent from 48Hz to 500Hz
Influence of Temperature ≤ 0.2% per 10K
Influence of Adjacent
Conductor
Influence of Adjacent
Conductor Position in Jaws
Influence of Frequency ≤ 2% from 65Hz to 500Hz
MECHANICAL
Operating Temperature 14° to 122°F (-10° to +50°C)
Storage Temperature -40° to 176°F (-40° to 80°C)
Operating Relative
Humidity
0 to 85% RH decreasing linearly above 35°C
Operating Altitude 0 to 2000m
Casing Protection Rating
(leak-proofing)
IP40
Fall Height 4.92 ft (1.5m) (IEC 68-2-32)
Shock Protection 3.52 oz (100g)/6ms/half-period (IEC 68-2-27)
Self-extinguishing Capability casing UL94 V2
Vibration Resistance IEC 68-2-6
Dimensions 4.43 x 1.48 x 1.02" (112.5 x 37.5 x 26mm)
Weight approx. 6.35 oz (180g)
SAFETY
Electrical EN 61010-1, 600V CAT III, Pollution Degree 2
Double Insulation Yes
CE Mark Yes
(1) Conditions of reference: 23°C ± 3°K, 20 to 75% RH, sinusoidal signal with frequency of 48 to 500Hz, distortion factor < 1% with
no DC component, external DC magnetic field < 40A/m, no external AC magnetic field, no external conductor with circulating current,
conductor centered for measurement, measurement instrument load impedance ≥ 1MΩ (10A calibre) & ≥ 10kΩ (100A calibre).
(2) With clamp closed.
a c /aa c
≤ 2mA/A at 50Hz
≤ 0.1% at 50/60Hz
(2)
(EN 60529 Ed. 1995)
MN03_2129.18 (pdf) 0109 Rev.01
Technical Assistance (800) 343-1391 www.aemc.com 2 of 4