AEMC JM840A Data sheet

AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com1of 4
AC Current Probe Model JM840A
The Model JM840A is a high performance AC current probe for higher currents. Excellent transformation and low phase shift, plus a broad frequency response, permit accurate measurements of current and power. The high quality magnetic core and uniform windings provide for accurate measurements up to 500A
AC/1000AAC/
1800A
AC. The “squared” jaw permits
multiple conductor or bus bar positioning. The Model JM840A provides excellent True RMS capabilities and reliable signal reproduction.
The Model JM840A first works as a traditional current transformer providing current outputs (mA) over a broad range of transformation ratios. The Model JM840A is designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges.

Features

Nominal range: 500AAC, 1000AAC,
1500A
AC (continuous cycle for the
full temperature range)
• Transformation ratio: 500:1, 1000:1, 1500:1
Output: 2mA, 1mA
AC/AAC and
0.66mA
AC/AAC
Designed for use on DMMs, power and harmonic meters, recorders or
instruments with AC current ranges

Applications

Field testing
Electrical utility
HVAC
Industrial maintenance
Laboratory
Plant maintenance
AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com2of 4

Specifications

MODELS JM840A
ELECTRICAL
Nominal Range 1500A Measurement Range 1 to 1800AAC Transformation Ratio 500:1. 1000:1, 1500:1 Output Signal 2mA
AC/AAC (1A @ 500A)
1mAAC/AAC (1A @ 1000A)
Accuracy (500A Range)
25A 4% of Reading 100A 3% of Reading 500A 3% of Reading
Phase Shift (500A Range)
25A 4° 100A 3.5° 500A
Accuracy (1000A Range)
50A 3% of Reading 200A 2% of Reading
1000A 1% of Reading
Phase Shift (1000A Range)
50A 3° 200A 1.5°
3000A
Accuracy (1500A Range)
75A 1.5% of Reading 300A 0.75% of Reading
1500A 0.5% of Reading
Phase Shift (1500A Range)
75A 1.5° 300A 0.75°
1500A 0.5°
Overload 700A for 10 min (500A);
1400A for 10 min (1000A);
1800A for 10 min (1500A)
Frequency Range 30 to 1500Hz; current
derating above 1500Hz
for continuous use
Load Impedance ≤5Ω
(500A, 1000A, 1500A)
Working/Common Mode Voltage
600V
AC
Output Termination Jack
MECHANICAL
Operating Temperature 14° to 122°F (-10° to 50°C) Storage Temperature -13° to 176°F (-25° to 80°C) Jaw Opening 3.54" (90mm) Maximum Conductor Size Cable: 2.52" Ø max (64mm); Bus bar: 1.97 x 5.31" (50 x 135mm); 2.52 x 3.94" (64 x 100mm) Dimensions 4.72 x 12.40 x 1.89" (120 x 315 x 48mm) Weight 2.65 lbs (1200g) Polycarbonate Material Handles: 10% fiberglass charged polycarbonate UL94 VO; Jaws: ABS UL V2
SAFETY
Electrical EN61010-2-32 Electromagnetic EN 50081-1 Class B; EN 50082-2 Electrostatic discharge IEC 100-4-2;
Compatibility Radiated field IEC 1000-4-3; Fast transients IEC 1000-4-4; Magnetic field at 50/60Hz IEC 1000-4-4
Double Insulation Yes
CE Mark Yes
Note: Reference conditions:
23°C ± 3°K, 20 to 85% RH, 45 to 65Hz, external magnetic field < 40A/m, no DC component, no external current carrying conductor, test sample centered.