AEMC JM840A Data sheet

Page 1
AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com1of 4
AC Current Probe Model JM840A
The Model JM840A is a high performance AC current probe for higher currents. Excellent transformation and low phase shift, plus a broad frequency response, permit accurate measurements of current and power. The high quality magnetic core and uniform windings provide for accurate measurements up to 500A
AC/1000AAC/
1800A
AC. The “squared” jaw permits
multiple conductor or bus bar positioning. The Model JM840A provides excellent True RMS capabilities and reliable signal reproduction.
The Model JM840A first works as a traditional current transformer providing current outputs (mA) over a broad range of transformation ratios. The Model JM840A is designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges.

Features

Nominal range: 500AAC, 1000AAC,
1500A
AC (continuous cycle for the
full temperature range)
• Transformation ratio: 500:1, 1000:1, 1500:1
Output: 2mA, 1mA
AC/AAC and
0.66mA
AC/AAC
Designed for use on DMMs, power and harmonic meters, recorders or
instruments with AC current ranges

Applications

Field testing
Electrical utility
HVAC
Industrial maintenance
Laboratory
Plant maintenance
Page 2
AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com2of 4

Specifications

MODELS JM840A
ELECTRICAL
Nominal Range 1500A Measurement Range 1 to 1800AAC Transformation Ratio 500:1. 1000:1, 1500:1 Output Signal 2mA
AC/AAC (1A @ 500A)
1mAAC/AAC (1A @ 1000A)
Accuracy (500A Range)
25A 4% of Reading 100A 3% of Reading 500A 3% of Reading
Phase Shift (500A Range)
25A 4° 100A 3.5° 500A
Accuracy (1000A Range)
50A 3% of Reading 200A 2% of Reading
1000A 1% of Reading
Phase Shift (1000A Range)
50A 3° 200A 1.5°
3000A
Accuracy (1500A Range)
75A 1.5% of Reading 300A 0.75% of Reading
1500A 0.5% of Reading
Phase Shift (1500A Range)
75A 1.5° 300A 0.75°
1500A 0.5°
Overload 700A for 10 min (500A);
1400A for 10 min (1000A);
1800A for 10 min (1500A)
Frequency Range 30 to 1500Hz; current
derating above 1500Hz
for continuous use
Load Impedance ≤5Ω
(500A, 1000A, 1500A)
Working/Common Mode Voltage
600V
AC
Output Termination Jack
MECHANICAL
Operating Temperature 14° to 122°F (-10° to 50°C) Storage Temperature -13° to 176°F (-25° to 80°C) Jaw Opening 3.54" (90mm) Maximum Conductor Size Cable: 2.52" Ø max (64mm); Bus bar: 1.97 x 5.31" (50 x 135mm); 2.52 x 3.94" (64 x 100mm) Dimensions 4.72 x 12.40 x 1.89" (120 x 315 x 48mm) Weight 2.65 lbs (1200g) Polycarbonate Material Handles: 10% fiberglass charged polycarbonate UL94 VO; Jaws: ABS UL V2
SAFETY
Electrical EN61010-2-32 Electromagnetic EN 50081-1 Class B; EN 50082-2 Electrostatic discharge IEC 100-4-2;
Compatibility Radiated field IEC 1000-4-3; Fast transients IEC 1000-4-4; Magnetic field at 50/60Hz IEC 1000-4-4
Double Insulation Yes
CE Mark Yes
Note: Reference conditions:
23°C ± 3°K, 20 to 85% RH, 45 to 65Hz, external magnetic field < 40A/m, no DC component, no external current carrying conductor, test sample centered.
Page 3
AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com3of 4
Ø=2.52" (64mm)

ORDERING INFORMATION CATALOG NO.

AC Current Probe Model JM840A (Jack – 2mA/A – 500A; 1mA/A – 1000A; .66mA/A – 1500A max) . . . . . . . . Cat. #2110.85
Includes a user manual
Accessories (Optional)
Banana plug adaptor (to nonrecessed plug) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #1017.45
Leads, set of 2, 5 ft safety (1000V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2111.29
Banana/BNC Connector XF-SS (4mm banana plug) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2111.32
Jacks:
Two standard safety banana jacks (4mm)
Cable max.
1.97 x 5.31" (50 x 135mm) or
2.52 x 3.94" (64 x 100mm) Bus Bar max.
P1 P2
12.01"
(305mm)
4.72"
(120mm)
1.89"
(48mm)
Page 4
AC Current Probes Model JM840A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com4of 4

Contact Us

United States and Canada:
Chauvin Arnoux
®
, Inc.
d.b.a. AEMC
®
Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 • Fax (508) 698-2118 www.aemc.com
Customer Support – for placing an order, obtaining price and delivery:
customerservice@aemc.com
Sales Department – for general sales information:
sales@aemc.com
Repair and Calibration Service – for information on repair and calibration, obtaining a user manual:
repair@aemc.com
Technical and Product Application Support – for technical and application support:
techinfo@aemc.com
Webmaster – for information regarding www.aemc.com:
webmaster@aemc.com
South America, Central America, Mexico, Caribbean, Australia and New Zealand:
Chauvin Arnoux
®
, Inc.
d.b.a. AEMC
®
Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 • Fax (978) 526-7605 export@aemc.com www.aemc.com
All other countries:
Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 • Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com
Loading...