AEMC 8230 Data sheet

Special product
features
M
Y
G
E
R
E
'
'
N
'
'
E
'
'
'
POWER QUALITY ANALYZERS, METERS & LOGGERS
Power Quality Meter
T
E
R
Model 8220
E
R
S
U
S
A
E
M
A measurement tool for electrical parameters
R
P
and distribution network disturbances
M
SPECIFICATIONS
H
A
S
R
E
R
U
S
A
E
S
M
MODEL 8220
M
O
N
I
ELECTRICAL
C
Voltage (TRMS) Phase-to-Phase: 660V; Phase-to-Neutral: 600V Current (TRMS)
MN Clamp: 0.2 to 6A/120A or 2 to 240A
MR Clamp: 10 to 1000A
AmpFlex®: 10 to 6500A
Frequency (Hz) 40 to 70Hz Other Measurements
kW, kvar, PF, DPF, VA, kWh, kvarh, VAh,
Phase Rotation, Temperature, RPM, Resistance,
Harmonics Sampling Frequency Data Storage
Stores nine sets of readings totaling up to
99 snapshots for volts, amps, power and harmonics
Power Source
Six 1.5V AA Alkaline batteries (included)
Battery Life
40 hrs with display off (recording mode)
MECHANICAL
Communication Port Display
Dimensions Weight Safety Rating
(1)
Crest factor at 6500 = 1
Three-line backlit color LCD digital display with custom icons
and adjustable brightness & contrast
8.3 x 4.3 x 2.4" (211 x 108 x 60mm)
EN 61010, 600V CAT III, IP54, Pollution Degree 2
KIT OPTION INCLUDES
8220 Kit
One user selectable current probe with 10 ft lead and black connector, black and red 10 ft voltage leads and alligator clips, optical USB cable, six 1.5V batteries, two safety test probes, carrying bag, and USB stick supplied with DataView and user manual.
8230 Kit
Current probe with 10 ft lead and black connector, black and red 10 ft voltage leads and alligator clips, optical USB cable, NiMH battery, 120V US wall charger, carrying bag, and USB stick supplied with DataView
®
software and user manual.
®
SR Clamp: 3 to 1200A
ac, 10 to 1400Adc
MiniFlex®: 10 to 1000A
Continuity, Diode Test
th
st
to 50
1
256 samples / cycle
8 hrs with display on
Optically isolated USB
1.9 lbs (0.88kg)
(1)
IP 54
Rated
FEATURES
Measures up to 660Vrms or Vdc
Measures up to 6500Aac or 1400Adc
(probe dependent)
Displays Min, Max and Average Volts and
Amps, Crest Factor, Peak Value and K-Factor
Calculates and displays Watts, vars and VA,
Power Factor and Displacement Power Factor for single-phase and balanced three-phase
Measures and records power systems (kW, VA, kvar)
Energy metering (kAh, varh, kWh)
Displays total harmonic distortion
(THD-F and THD-R) for voltage and current
Displays individual harmonic values and % for
volts and amps through the 50
The Max and Min RMS measurements are
calculated every half-period
Captures and displays inrush current
Calculates and displays phase rotation and RPM
Displays temperature in both °F and °C
Displays resistance up to 2000
Conducts continuity and diode tests
Stores up to nine complete sets of readings
for all volt, amp, power and harmonic measurements
Operates on batteries or optional power adapter
Download stored data snapshots to DataView
software via optical USB port (included)
Includes FREE DataView
data storage, real-time waveform display, analysis and report generation
th
harmonic
®
®
software for configuring
CATALOG NO. DESCRIPTION
2130.90 Power Quality Meter Model 8220 (no probes)
2130.91 Power Quality Meter Model 8220 w/MN93-BK
2130.93 Power Quality Meter Model 8220 w/24" 193-24-BK (AmpFlex
2130.96 Power Quality Meter Model 8220 w/MN193-BK
www.aemc.com
®
)
Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS
Single-Phase Power Quality Analyzer
PowerPad® Jr. Model 8230
Special product
features
E
I
R
N
U
S
A
E
M
R
U
S
H
power quality work on single- or three-phase
IP 54
Rated
FEATURES
Measures up to 660Vrms or Vdc
Measures up to 6500Aac or 1400Adc
(probe dependent)
Displays Min, Max and Average Volts and Amps,
Crest Factor, Peak Value and K-Factor
Calculates and displays Watts, vars and VA,
Power Factor and Displacement Power Factor for single-phase and balanced three-phase
Measures and records power systems (kW, VA, kvar)
Energy metering (kAh, varh, kWh)
Displays total harmonic distortion
(THD-F and THD-R) for voltage and current
Displays individual harmonic values and % for Volts
and Amps through the 50
Captures, displays and stores inrush current
waveforms and statistics
Stores up to eight screen captures
Stores up to 1MB of trend recorded data
Configurable from DataView
Download stored data to DataView
optical USB port (included)
Captures up to 4096 alarm events from up to
10 different thresholds
Displays and records up to 17 different power
quality parameters
Includes FREE DataView
data storage, real-time waveform display, analysis and report generation
The Max and Min RMS measurements are
calculated every half-period
th
harmonic
®
software or front panel
®
software via
®
software for configuring
Measure and carry out diagnostic work and
balanced load networks
SPECIFICATIONS
MODEL 8230
ELECTRICAL
Voltage (TRMS)
Current (TRMS)
Frequency (Hz) 40 to 70Hz Other Measurements
Harmonics
kW, kvar, PF, DPF, kWh, kvarh, kVAh, K-Factor, Flicker, Harmonic Phase Shift, Phase Rotation
THD-R, THD-F, V, A, VA, 1st to 50th, Direction, Sequence
Sampling Frequency Data Storage
Power Source
Battery Life
MECHANICAL
Communication Port Display
Dimensions Weight Safety Rating
(1)
Crest factor at 6500 = 1
Configuration
Waveform Mode
¼ VGA (320 x 240) color LCD digital & graphical
display with adjustable brightness & contrast
EN 61010, 600V CAT III, IP54, Pollution Degree 2
Phase-to-Phase: 660V;
Phase-to-Neutral: 600V
MN Clamp: 0.2 to 6A/120A or 2 to 240A
MR Clamp: 10 to 1000A
ac, 10 to 1400Adc
SR Clamp: 3 to 1200A
MiniFlex®: 10 to 1000A
AmpFlex®: 10 to 6500A
(1)
256 samples/cycle
1.5MB partitioned for waveforms, alarms and trend recording
NiMH rechargeable battery pack (included)
AC Supply: 120/230Vac (50/60Hz)
8 hrs with display on
40 hrs with display off (recording mode)
Optically isolated USB
8.3 x 4.3 x 2.4" (211 x 108 x 60mm)
1.9 lbs (0.88kg)
Recording Setup
Trend Recording
Inrush Mode
Harmonics Mode
E
S
R
A
E
H
C
P
O
R
E
D
L
1
I
G
N
N
G
I
S
A
V
W
E
F
Y
O
A
L
R
P
M
S
I
S
D
CATALOG NO. DESCRIPTION
2130.81 PowerPad® Jr. Model 8230 (no probes)
2130.82 PowerPad
2130.87 PowerPad
®
Jr. Model 8230 w/MN93-BK
®
Jr. Model 8230 w/MN193-BK
Technical Assistance (800) 343-1391
www.aemc.com
POWER QUALITY ANALYZERS, METERS & LOGGERS
Optional Accessories
SENSOR TYPE CURRENT RANGE
MiniFlex® MA193-BK *
10" or 14" sensor
MR193-BK
Battery operated
SR193-BK
100mA to 3000Aac
1 to 1000Aac 1 to 1300Adc
1 to 1200Aac
ACCURACY
(TYPICAL)
±1%
±2.5% -0.80°
±0.3% 0.2°
TYPICAL
ON Φ AT
50/60HZ
ERROR
MAX
CONDUCTOR
SIZE
2.75"
(70mm)
1.6"
(41mm)
2.05"
(52mm)
USED WITH
MODEL
PEL 102 PEL 103 PEL 105
8333 8336
8220
8230 PEL 102 PEL 103 PEL 105
8333
8336
8435
8220
8230 PEL 102 PEL 103 PEL 105
8333
8336
8435
LIMITED
RANGE IF
USED WITH
MODEL
8220 8230 8435
N/A 2140.28
N/A 2140.33
CATALOG NUMBER
2140.48
(10" sensor)
2140.50
(14" sensor)
AmpFlex® 193-BK *
100mA to 12,000Aac
24" or 36" sensor
AmpFlex® A196
10 to 10,000Aac
24" sensor IP67
Maximum current reduced by a factor of 2 for 400Hz fundamental frequency.
*
±1%
±2%
7.64"
(190mm)
or
11.46"
(290mm)
5.73"
(145mm)
PEL 102 PEL 103 PEL 105
8333
8336
PEL 105
8435
8220 8230 8435
N/A
2140.34
(24" sensor)
2140.35
(36" sensor)
2140.75
(24" sensor)
www.aemc.com
Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS
Optional Accessories
MN93-BK
MN193-BK
SL261 **
J93
SENSOR TYPE CURRENT RANGE
0.5 to 240Aac
100A
5A
100A
10A
200mA to 120Aac ±1% 0.75°
5mA to 6Aac ±1% 1.7°
5 to 100Aac/dc ±4% ±0.5°
50mA to 10Aac/dc ±3% ±1°
Battery operated
50 to 3500Aac 50 to 5000Adc
Battery operated
ACCURACY
(TYPICAL)
±1% 0.8°
±1% ±1°
TYPICAL
ERROR ON Φ AT 50/60HZ
MAX
CONDUCTOR
SIZE
0.78"
(20mm)
0.78"
(20mm)
0.46"
(11.8mm)
2.83"
(72mm)
Busbar:
5 x 1.69"
(127 x 43mm)
USED WITH
MODEL
PEL 102 PEL 103 PEL 105
8333 8336 8435
8220
8230 PEL 102 PEL 103 PEL 105
8333
8336
8435
8220
8230 PEL 102 PEL 103 PEL 105
8333
8336
8435
PEL 102 PEL 103 PEL 105
8333
8336
8435
LIMITED
RANGE IF
USED WITH
MODEL
8220 8230
N/A 2140.36
N/A 1201.51
N/A 2140.49
CATALOG NUMBER
2140.32
Note: Refer to the Power Meter’s product user manual for complete specifications.
All current sensors can be used with the Models 8435 and PEL 105. However, only the A196 flexible sensors are waterproof.
CATALOG NO. DESCRIPTION
1201.51 AC/DC Current Probe Model SL261 (BNC)
2140.37 Adapter – US 110V Power Adapter (eliminates need for batteries) 8220 & 8230 only
2140.28 AC/DC Current Probe Model MR193-BK
2140.32 AC Current Probe Model MN93-BK
2140.33 AC Current Probe Model SR193-BK
2140.34 AmpFlex
2140.35 AmpFlex
2140.36 AC Current Probe Model MN193-BK
2140.48 MiniFlex
2140.49 AC/DC Current Probe Model J93-BK
2140.50 MiniFlex
2140.75 AmpFlex
®
Sensor 24" Model 193-24-BK
®
Sensor 36" Model 193-36-BK
®
Sensor 10" Model MA193-10-BK
®
Sensor 14" Model MA193-14-BK
®
Sensor 24" (waterproof - IP67) Model A196-24-BK
Technical Assistance (800) 343-1391
** AC/DC Current Probe BNC Adapter for Model SL261 only Catalog #2140.40
www.aemc.com
DATAVIEW®
Software for Power & Energy Loggers
Data Analysis and Reporting Software
Configure all functions of the Power & Energy Loggers
Display and analyze real-time data on your PC
Configure functions and parameters from your PC
Customize views, templates and reports to your exact needs
Create and store a complete library of configurations that
can be uploaded as needed
Zoom in and out and pan through sections of the graph to
analyze the data
Download, display and analyze recorded data
Display waveforms, trend graphs, harmonic spectrums,
text summaries, transients, event logs and stored alarms
Print reports using standard or custom templates you design
Free updates are available on our website www.aemc.com
Typical DataView® Functional, Digital & Graphical Displays
Display all harmonics from 1
Clear and easy setup of all functions from one tabbed dialog box.
Display real-time waveforms by phase, parameter or total.
form for voltage, current and power.
st
to 50th in bar graph
Display real-time Phasor diagrams. Includes unbalance for both voltage and current.
www.aemc.com
Display power and energy parameters – both instantaneous and total.
Display harmonics in a text table from harmonic 0 (DC) through the 50
Technical Assistance (800) 343-1391
th
.
Loading...