Transmitter/Receiver
Cable Tracer
Model 6681
Detects and
locates faults in
electrical cables,
telecommunication
cables, live and
de-energized
conductors buried
or in walls
• Operates in both single-pole and two-pole modes
• Locates and traces hidden cables
• Detects and locates line breaks
• Detects faults in floor radiant heating systems
• Detects constricted sections of non-metallic pipes
• Detects circuit breakers/fuses
• Detects short circuits
• Backlight and flashlight functions
• Compliant with standards electrical safety standard EN 61010-1 and electromagnetic compatibility standard EN 61326-1
Our products are backed by over 100 years of experience in test and measurement
equipment, and encompass the latest international standards for quality and safety.
Technical Hotline: (800) 343-1391
www.aemc.com
Technical Assistance (800) 343-1391
www.aemc.com
1
Page 2
Renovation. Improvement. Maintenance. A Single Instrument for Locating All Your Metal Conductors
Locate hidden cables
To assist your maintenance, renovation and improvement
Large LCD screen
with optimized contrast,
bargraph and backlighting
for the receiver
The transmitter
displays its
battery-charge
status
work, the AEMC® Model 6881 detects electrical power cables,
telecommunication cables, metal pipes and even restrictions in
non-metal conduit.
Comprising a transmitter and a receiver, the Model 6681 is
simple to use on both current-carrying and non-current-carrying
electrical wiring. Its digital technology overcomes interference
and disturbance signals to provide precise location details. The
receiver displays the value of the signal measured, which
is also shown on a bar chart, and emits audible signals
whose amplitudes vary in proportion to the signal
distance.
This makes it very simple to follow electrical cables through walls or detect buried pipes. To guide you and simplify your work, the receiver can quickly identify the circuit-breaker or fuses corresponding to the power outlet which the transmitter is connected to. It can be used to detect short-circuits or breaks on existing installations. For example, it is possible to detect faults
in under-fl oor radiant heating pipes. The Model 6681 is
lightweight and includes a complete set of accessories
for direct measurement.
Output power adjustment
or transmission code
selection
The receiver displays its battery-charge status
and the battery-charge status of the transmitter
Automatic/manual sensitivity detection adjustment
Selects cable
detection or line-voltage
detection mode
For excellent visibility even in the darkest places,
the transmitter and receiver include a powerful
built-in fl ashlight
Flashlight activation
2
www.aemc.com
Technical Assistance (800) 343-1391
Page 3
Location and tracking of
branches and outlets
Identifi cation of the network
voltage and detection of breaks in
the wiring
Circuit breaker identifi cation
Locate line interruptions
Short circuit detection in walls,
fl ooring or under ground
Trace buried cable runs
Fault detection in radiant
heating systems
PRODUCT INCLUDES
6681
Soft carrying case, set of two 4mm red/black test leads, set of two alligator clips, set of two test probes, ground rod, 9V battery, 6 x 1.5V AAA batteries and user manual.
Detect crimped or obstructed
sections of a non-metallic pipe
Detection of metal heating ducts
and water pipes
CATALOG NO. DESCRIPTION
2127.85 Cable Locator Model 6681
Technical Assistance (800) 343-1391
www.aemc.com
3
Page 4
www.aemc.com
Volume 17
Cable Testers
Clamp-On Meters
Current Measurement Probes
Data Loggers
DC Power Supplies
Decade Boxes
Digital Multimeters
Electrical Test Tools
Environmental Testers
Ground Resistance Testers
High Voltage Testers
Leakage Current Meters and Probes
Megohmmeters
Micro-Ohmmeters
Oscilloscopes
Power Quality Analyzers, Meters and Energy Loggers
Thermal Imaging
Transformer Ratiometers
Other Products from the Chauvin Arnoux Group
TEST & MEASUREMENT INSTRUMENTS
www.aemc.com Technical Hotline: (800) 343-1391
MODEL 6681 (transmitter) Display Output Signal Frequency External Voltage
Measurement Range Functions
Power Supply Dimension Weight Electrical Safety
MODEL 6681 (receiver) Display
Backlit LCD with display of functions and bargraph, transmission
Detection Depth
Single-Pole Application Two-Pole Application
Simple Looping Line Line Voltage Detection Functions
Power Supply Dimension Weight Electrical Safety
LCD screen with display of functions and bargraph
125kHz
12 to 300V
AC/DC
Digital coding of signals for easy signal identifi cation,
selection of transmission signal code, fl ashlight
9V battery
7.48 x 3.5 x 1.67" (190 x 89 x 42.5mm)
14.81oz (420g) with battery 300V CAT III
code, receiver and transmitter battery-charge status
0 to 6ft (0 to 2m)
0 to 1.6ft (0 to 0.5m)
Up to 8.2ft (2.5m)
Approximately 0 to 1.3ft (0 to 0.4m)
Automatic shutdown, automatic or manual adjustment
of reception sensitivity, fl ashlight
6 x 1.5V AAA batteries
9.5 x 3.07 x 1.5" (241.5 x 78 x 38.5mm) 12 oz (36 g) with batteries
300V CAT III
Call the AEMC® Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391
Chauvin Arnoux®, Inc. d.b.a AEMC® Instruments • 200 Foxborough Blvd. • Foxborough, MA 02035 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118
Visit our website at www.aemc.com
Export Department: (978) 526-7667 • Fax (978) 526-7605 • E-mail: export@aemc.com
950.BR-6681_0717Rev00 Printed in the USA
Loading...