SPECIFICATIONS
MODELS 6522 6524 6526 6532 6534 6536
INSULATION TESTS
Test Voltages
Insulation Resistance
PI/DAR Ratios Test Lock Timer Auto Discharge Automatic Test Inhibit
DMM FUNCTIONS
Voltage Resistance Continuity Test Current Capacitance Measurement Frequency
GENERAL FUNCTIONS
Alarm Rel Auto Power OFF Data Hold Test Lead Compensation Remote Probe Memory
Bluetooth
®
DataView Display Type
Display Counts Backlight Safety Power Supply Protection Magnetic Mount Additional Features
Applications
Software
250V, 500V, 1000V
40G
(40000M)
Yes Yes Yes
Yes Yes Yes Yes Yes Yes
0 to 40min 0 to 40min 0 to 40min 0 to 40min 0 to 40min 0 to 40min
Yes Yes Yes Yes Yes Yes
>25V >25V >25V >25V >25V >25V
700Vac/dc 700Vac/dc 700Vac/dc 700Vac/dc 700Vac/dc 700Vac/dc
1000k 1000k 1000k 1000k 1000k
10 10, 100 10, 100 10, 100 10, 100 10, 100
200mA/20mA 200mA/20mA 200mA/20mA 200mA/20mA 200mA/20mA 200mA/20mA
0.1n to 10µF 0.1n to 10µF – – 15.3 to 800Hz 15.3 to 800Hz 15.3 to 800Hz
Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes (optional) Yes (optional) Yes (optional) Yes (optional) Yes (optional) Yes (optional)
300 measurements 1300 measurements 1300 measurements 1300 measurements
2.1 Class II 2.1 Class II 2.1 Class II
Included Included Included
Digital w/Analog
Bargraph
4000 4000 4000 4000 4000 4000
Yes Yes Yes Yes Yes Yes
600V CAT IV 600V CAT IV 600V CAT IV 600V CAT IV 600V CAT IV 600V CAT IV
6 x AA Alkaline 6 x AA Alkaline 6 x AA Alkaline 6 x AA Alkaline 6 x AA Alkaline 6 x AA Alkaline
IP 54/IK 04 IP 54/IK 04 IP 54/IK 04 IP 54/IK 04 IP 54/IK 04 IP 54/IK 04
Yes Yes Yes Yes Yes Yes
Industrial
Maintenance
50V, 100V, 250V,
500V, 1000V
200G
(200000M)
Digital w/Analog
Bargraph
Industrial
Maintenance
50V, 100V, 250V,
500V, 1000V
200G
(200000M)
Digital w/Analog
Bargraph
Green/Red
Pass/Fail Indicator
Industrial
Maintenance
50V, 100V
20G
(20000M)
Digital w/Analog
Bargraph
10V, 25V, 100V,
250V, 500V
50G
(50000M)
Digital w/Analog
Bargraph
Cable length
measurement
(0 to 100km)
Telecom Electronics, ESD
Variable 10 to 100V
(1V steps)
20G
(20000M)
Digital w/Analog
Bargraph
Avionics, Space,
Defense
CATALOG NO. DESCRIPTION
2155.51 Megohmmeter Model 6522 (Digital w/Analog Bargraph, 250V, 500V, 1000V, Ohm, Continuity, V)
2155.52
2155.53
2155.54
2155.55
2155.56 Megohmmeter Model 6536 (Digital w/Analog Bargraph, Alarm, Variable 10V to 100V, Ohm, Continuity, V, k)
www.aemc.com
Megohmmeter Model 6524 (Digital w/Analog Bargraph, Alarm, 50V, 100V, 250V, 500V, 1000V, Ohm, Continuity, V, k, Mem)
Megohmmeter Model 6526 (Digital w/Analog Bargraph, Alarm, 50V, 100V, 250V, 500V, 1000V, Ohm, Continuity, V, k, Cap, Mem, Bluetooth w/DataView
Megohmmeter Model 6532 (Digital w/Analog Bargraph, Alarm, 50V, 100V, Ohm, Continuity, V, k, Cap, Mem, Bluetooth w/DataView
Megohmmeter Model 6534 (Digital w/Analog Bargraph, Alarm, 10V, 25V, 100V, 250V, 500V, Ohm, Continuity, V, k, Mem, Bluetooth w/DataView
software)
software)
software)
Technical Assistance (800) 343-1391
Page 2
Models 6522, 6524, 6526, 6532, 6534 & 6536
Front Panel & Functional Displays
Analog with bargraph display of insulation resistance
Secondary display
Main display
Function indicators
IP 54
Rated
KEY FEATURES*
True Megohmmeter
Test voltage from 10V to 1000V
Insulation resistance up to 200G
Manual, Lock, Timer modes &
PI/DAR Ratio calculations
Alarms with Green/Red Pass/Fail indicator light
200mA/20mA continuity with active
protection without fuses
Measurement of V (TRMS & DC), F, , kΩ,
Hz, C and cable length
∆Rel mode for comparison measurements
Configurable alarms
Data Storage
Automatic discharge after test
Automatic test inhibit if device under
test is energized >25V
* Features are model dependent
®
Access to the instrument information and setup for Test Lock, Timer, PI/DAR and Times
Navigation buttons:
Display instrument
information
Turn buzzer
on or off
Turn power
saver on or off
Program test time
Select displayed
parameters
measurements to
a reference value
Program alarm
set points
Memory recall/ Bluetooth activation
Alarm activation/ deactivation with Pass/Fail indication (model dependent)
selection switch
Data Analysis and Reporting Software
Configure all functions of the Megohmmeter
Models 6526, 6532 & 6534
Print reports of all test results
Select test voltage and run tests from
your computer with a simple click and execute process
Capture and display data in real-time
Test lead
resistance
compensation
Rel set and
compare
Test button
Test function
Models 6522 & 6524
Soft carrying pouch, two 1.5m test leads (red/black), two alligator
clips (red/black), 1 black test probe, 6 AA batteries and user manual.
Model 6536
Soft carrying pouch, two 1.5m test leads (red/black), two alligator clips (red/black), 1 black test probe, two "grip" probes (red/black),
6 AA batteries and user manual.
Technical Assistance (800) 343-1391
PRODUCT INCLUDES
Models 6526, 6532 & 6534
Soft carrying pouch, two 1.5m test leads
(red/black), two alligator clips (red/black),
1 black test probe, two "grip" probes
(red/black) (Models 6532 & 6534), 6 AA
batteries, quick start guide, and a USB stick
with DataView
®
software and user manual.
www.aemc.com
Page 3
DATAVIEW®
Software for Megohmmeters
Data Analysis and Reporting Software
Configure all functions of the Megohmmeter Models 1060, 5060, 5070, 6526, 6532, 6534, 6550 & 6555
Print reports of all test results
Select test voltage and run tests from
your computer with a simple click and execute process
Capture and display data in real-time
Retrieve data from the instrument’s
memory for:
Over 1500 insulation resistance
measurements
Over 4000 resistance measurements
Typical DataView® Functional Displays
Four tabbed dialog boxes allow for clear and easy setup of all functions of the Model 5070, including setup for variable voltage and alarm set points, as well as step voltage tests and temperature compensation.
Variable Voltage selections from 40 to 5100V and can also be programmed along with alarm set points.
Display DAR and PI ratios
Plot graphs of manual and timed tests
Include your analysis comments section
with the report
Store a library of setups for different
applications
Certification of results through report
generation
Free updates are available on our website
www.aemc.com
Model 5070 includes Ramp Function which allows programming of three different ramp test profiles, each containing up to five voltage steps between 40 and 5100V and time per step of up to 10 hours.
Test result status box displays complete test results in real-time
www.aemc.com
Step voltage during
the test run
Insulation resistance
with temperature
compensation
Run test and display text and graphical results from one dialog box. Model 5070 also displays step voltage.
Technical Assistance (800) 343-1391