SPECIFICATIONS
R
T
MODELS 6416 & 6417
ELECTRICAL
N
O
I
Ground
Resistance
Auto-Ranging
1 to 199Ω
Current
Measurement
Auto-Ranging
1mA to 40A
Selectable
Measurement
Frequency
Current
Measurement
Frequency
Inductance
Measurement
Current Overload
Communication
Power Source
PRODUCT INCLUDES
Model 6416 includes a hard carrying
case, calibration loop, four 1.5V AA
batteries, ground workbook and user
manual.
Model 6417 also includes a Bluetooth
USB adapter, quick start guide, and
a USB stick with DataView
ground workbook and user manual.
Measurement
Range
Resolution
0.010 to 0.099Ω 0.001Ω ±1.5% ±0.01Ω
0.10 to 0.99Ω 0.01Ω ±1.5% ±0.02Ω
1.0 to 49.9Ω 0.1Ω ±1.5% ±0.1Ω
50.0 to 99.5Ω 0.5Ω ±2% ±0.5Ω
100 to 199Ω 1Ω ±3% ±1Ω
200 to 395Ω 5Ω ±5% ±5Ω
400 to 590Ω 10Ω ±10% ±10Ω
600 to 1150Ω 50Ω 20% approx
1200 to 1500Ω 50Ω 25% approx
0.200 to 0.999mA 1µA ±2% ±50µA
1.000 to 2.990mA
3.00 to 9.99mA
10.00 to 29.90mA
30.0 to 99.9mA
100.0 to 299.0mA
0.300 to 0.990A
1.000 to 2.990A
3.00 to 39.99A
10µA ±2% ±50µA
100µA ±2% ±100µA
1mA ±2% ±1mA
10mA ±2% ±10mA
50, 60, 128 or 2083Hz
47 to 800Hz
10 to 100µH;
100 to 500µH
OL displayed above 39.99Arms
Bluetooth connection (Model 6417 only)
4x1.5V LR6 (AA) Alkaline batteries or 4 NiMH batteries;
Battery life: 12 hours, or 1440 30-second
measurements approx.
®
software,
Accuracy
(% of Reading)
IP
40
Rated
* * *
*Model 6417 only
FEATURES
• Ground voltage indication
(warns of possible unsafe conditions)
• Large multi-function bright yellow organic LED
display (OLED)
• Selectable test frequency
(improves accuracy in inductive environments)
• Clamping diameter of 35mm
with large jaw design
• Storage of measurements
(Ω and/or A, with time-stamping)
Model 6416: up to 300 measurements stored
Model 6417: up to 2000 measurements stored
•
View stored measurements on the
OLED display or via Bluetooth
communicates up to 30 ft)
Android™ based mobile application
• Auto Power OFF function
• Alarm function with adjustable set point and
buzzer for quick field checks for volts, amps
and ohms
• Rugged Lexan® head and body construction
resists breakage
• Alarm settings and stored memory information
saved during shutdown
• Includes DataView® software for data storage,
real-time display, analysis, report generation
and system configuration (Model 6417)
• Noise icon and buzzer alert user to presence of
dangerous voltage and current levels
• Designed to EN 61010-1,
600V CAT IV safety standards
(Class 2 -
to a PC or the
(Model 6417)
www.aemc.com
Technical Assistance (800) 343-1391
![](/html/6d/6d39/6d39c676167a2fff8ac6e7aa24d9d787b6e84ad023c4eb1a9186493e7c4ee40e/bg2.png)
POWER QUALITY ANALYZERS, METERS & LOGGERS
GROUND RESISTANCE TESTERS
Disturbance indicator (current) in the loop
HOLD Function active
Buzzer is displayed when active
Measurement
date/time display
Advanced Mode selection
Indicates when the inductive
component is negligible in
Advanced Mode
Main measurement display
Measurement unit display
Data Storage Mode
Memory Recall Mode
Memory index number display
Bluetooth connection indicator
(active for 6417 only)
Three-Phase Power Quality Analyzer
Note: Display shown larger than real size.
Multi-Function
Models 6416 & 6417
Functional Displays
Incorrect jaw closing indicator
Auto Power OFF active
Battery charge indicator
4000-count upper
measurement display
Upper display
measurement unit
Main display
measurement unit
Hazardous voltage indicator
Alarm measurement
display unit
Alarm threshold display
Alarm active indicator
Measurement Results Memory Recall Mode Alarm
Displays the leakage current and loop
impedance at the test frequency
Measurement storage date-time screen Indicates voltage/current alarm threshold
along with the direction of impedance
Ground Voltage Current Disturbance Impedance Over Range
Indicates voltage potential at the point
of measurement
Indicates that the current is greater
than 10A
Indicates that the impedance is greater
than 1500
Ω
CATALOG NO. DESCRIPTION
2141.01 Ground Resistance Tester Model 6416 (Clamp-On, Alarm, Memory)
2141.02 Ground Resistance Tester Model 6417 (Clamp-On, Bluetooth, Alarm, Memory)
Technical Assistance (800) 343-1391
www.aemc.com