AEG-Electrolux 570D-M, 570D-M9 User Manual

DL 4150 - CHDL 4150
HL 4150 - DL 6250
570 D - 5708 D
Cooker Hood
Cappa aspirante
Campana extractora
Exaustor
Operating and Installation Instructions
Instrucciones de montaje y manejo
Manual de Instruções
Contents
Safety warnings 3
For the user 3 For the installer 4
Description of the Appliance 6
Extraction mode 6 Recirculation mode 6
Control Panel 7
Maintenance and care 8
Cleaning the hood 8 Metal grease filter 8 Removing the metal grease filter 8 Charcoal filter 10 Changing the light bulb 11
What to do if 12
Special accessories 13
Technical assistance service 13
Technical Specifications 14
Electrical connection 15
Installation 16 Removing the hood from cabinet 18 Relocating the control unit (Only 570 D - 5708 D) 19
2
Safety warnings
For the user
 The cooker hood is designed to extract unpleasant odours from the
kitchen, it will not extract steam.
 Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
 Also, when frying, keep the deep frying pan on the cooker top/
cooker under careful control.  The hot oil in the frying pan might ignite due to overheating.  The risk of self-ignition increases when the oil being used is dirty.  It is extremely important to note that overheating can cause a fire.  Never carry out any flambé cooking under the hood.Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).  It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.
This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
3
For the installer
 When used as an extractor unit, the hood must be fitted with a hose
having preferably the same diameter as the outlet hole. Only 5708 D: this model is equipped with two outlet hole. 2 hoses are therefore necessary for discharging the fumes.
When installing the hood, make sure you respect the following
minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 650 mm
models (CH)DL 4150-HL 4150-DL6250 only 600 mm
gas cookers 700 mm
The hood can be installed above these heights but for optimum performance it should be installed at the distance quoted for the appropriate heat source.
 The national standard on fuel-burning systems specifies a maxi-
mum depression of 0.04 bar in such rooms.
 The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
 The air outlet installation must comply with the regulations laid down
by the relevant authorities.
 When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.
 National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.
 Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi­mately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.
 If you have any doubts, contact the relevant controlling authority or
building inspectors office.
 Since the rule for rooms with fuel burning appliances is outlet hole
of the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.
 If the hood is used in its filtering function, it will operate simply and
safely in the above conditions without the need for any of the
4
aforementioned measures.  When the hood is used in its extractor function, the following rules
must be followed to obtain optimal operation:
 short and straight outlet hose
 keep bends in outlet hose to a minimum
 never install the hoses with an acute angle, they must always
follow a gentle curve.
 keep the hose as large as possible (preferably the same diam-
eter as the outlet hole).
 Failure to observe these basic instructions will drastically reduce the
performance and increase the noise levels of the extractor hood.
5
Description of the Appliance
The cooker hood is designed to extract unpleasant odours
from the kitchen, it will not extract steam.
 The hood is supplied as an extractor unit and can also be used with
a recirculation mode by fitting a charcoal filter.
 In some models the charcoal filter is supplied. The hood, therefore,
can be used immediately in the recirculation mode. We advise removing the charcoal filter to use the hood in the extraction mode.
Extraction mode
 In this mode fumes are extracted to the outside via a hose
connected to the coupling ring. Fig. 1.
 In order to obtain the best performance the hose should have a
diameter equal to the outlet hole. Only 5708 D: this model is equipped with two outlet hole. 2 hoses are therefore necessary for discharging the fumes.
Only for model DL 4150-CHDL 4150-HL 4150:
Should there already be an hose of diameter 100 mm that ducts to the outside through the walls or roof, it is possible to use the 120/ 100 mm adapter. In this case the hood will be slightly noisier.
Coupling ring
510 710
Fig. 1
Filter Version
 The air is filtered through a charcoal filter and
returned to the kitchen. Fig. 2.
 You will need an original charcoal filter for the
filtering function. (See Special Accessories).
6
Bayonet screw fitting (Only 570 D (1x) - 5708 D (2x))
Fig. 2